30
DIRECT VENT DIAGRAM
DIRECT VENT INSTALLATIONS
Direct Vent combustion air intake drains are required in certain
Direct Vent Air Intake Moisture Protection
(page 26) and
below.
12” MINIMUM CLEARANCE
ABOVE HIGHEST ANTICIPATED
SNOW LEVEL
EXHAUST
*
*
Figure 26. Direct Vent Roof Vent - Typical
*
*
12” MINIMUM CLEARANCE
ABOVE HIGHEST ANTICIPATED
SNOW LEVEL
Figure 27.
Direct Vent Roof Vent Concentric
24” minimum
separation.
Exhaust must
be at same level
or above intake
terminal.
Snorkeling is allowed to
achieve proper clearance. The
snorkel must be securely
supported.
*
*
24”
12” minimum clearance
above highest anticipated
snow level or grade.
12”
Figure 28. Sidewall Vent - Typical
*
*
Figure 29. Sidewall Vent - Concentric
*Direct Vent combustion air intake drains are required in certain
situations.
See
Direct Vent Air Intake Moisture Protection
.