User Manual
26
(Figure 5.7.1.3)
7. VLAN Configuration of Single Ring
1. Need to set one port as managed port, managed port and CPU port must in a same VLAN, figure
as 5.7.1.4, port 1 is managed port.
2. The port that already set in ring network port, the VLAN port type must Trunk and take Tag, figure
as 5.7.1.4.
(Figure 5.7.1.4)
8. Typical VLAN Configuration
Suppose switch‘s port 3, 4, 5 satisfied to the requirements as follows: port 3 can intercommunicate
with Port 5, Port 4 can intercommunicate with Port 5, Port
3 can‘s intercommunicate with Port 4, How to
set VLAN? (
Not consider the configuration of other VLAN)
Let‘s analyse at first, port 3 can intercommunicate with Port 5, the port must belong to a same
member of VLAN, the same, Port 4 can intercommunicate with Port 5, the port must belong to a same
member of VLAN, port 3 and port 4 belongs to different VLAN, figure as 5.7.1.5
1. Port 3
‘s PVID: 2, Port 4‘s PVID: 3, Port 5‘s PVID: 4, port type are both Access.
2. Add VLAN2, VLAN3, VLAN4, the member is 3 and 5, 4 and 5, 3, 4 and 5. Port type is Untagged.