User Manual
6
2.7 LED Indicator
System Indication LED
Led
State
Description
P1
ON
PWR1 is connected and operates properly.
OFF
PWR1 is not connected or operates abnormally.
P2
ON
PWR2 is connected and operates properly.
OFF
PWR2 is not connected or operates abnormally.
RUN
ON/OFF The system is running abnormally.
Blinking
The system is running properly.
ALM
ON
When the alarm is enabled, power or the port‘s link is inactive.
OFF
Power and the port‘s link is active, the alarm is disabled.
1~5
ON
The Ethernet port is connected properly.
Blinking
The Ethernet port is connected and data is being transmitted.
OFF
The Ethernet port is not connected properly.
TX(1~2)
Blinking
The serial port is transmitting data
OFF
No serial data transmission
RX(1~2)
Blinking
The serial port is receiving data
OFF
No serial data received
2.8 Installation
Before installation, confirm that the work environment meet the installation require, including the power
needs and abundant space. Whether it is close to the connection equipment and other equipment are
prepared or not.
1. Avoid in the sunshine, keep away from the heat fountainhead or the area where in intense EMI.
2. Examine the cables and plugs that installation requirements.
3. Examine whether the cables be seemly or not (less than 100m) according to reasonable scheme.
4. Power: Redundant, dual 12-48VDC power input
5. Environment: working temperature: -40
~
75
℃
Storage Temperature: -40
~
85
℃
Relative humidity 5%
~
95%
DIN Rail Installation
In order to use in industrial environments expediently, the switch adopt 35mm DIN-Rail installation, the
installation steps as below:
1. Examine the DIN-Rail attachment
2. Examine DIN-Rail whether be firm and the position is suitability or not.
3. Insert the top of the DIN-Rail into the slot just below the stiff metal spring.
4. The DIN-Rail attachment unit will snap into place as shown below.