background image

3

Explanation of Signal Word Consequences

   

WARNING:

Indicates a hazardous situation which, if not avoided, could result in serious injury or death.

  

NOTICE:

Indicates a situation which, if not avoided, could result in property damage.

 

WARNING:

Read entire product manual. Failure to follow all product instructions and warnings could cause personal 

injury from exposure to contaminants and/or property damage due to water leakage or flooding.

•  DO NOT 

use with water that is microbiologically unsafe or of unknown quality without adequate disinfection 

before or after the system. Systems certified for cyst reduction may be used on disinfected water that may 

contain filterable cysts.

•  THIS SYSTEM DOES NOT REMOVE ALL SUBSTANCES THAT COULD BE PRESENT IN DRINKING WATER. 

This system reduces the listed substances identified in the Performance Data Sheet.

•  VERIFY THIS SYSTEM 

meets your water treatment needs by checking your incoming water source quality and 

comparing to the system’s capabilities described in the Performance Data Sheet. Check water source quality 

by contacting your local water authority and/or having water tested by a qualified laboratory. Check water 

quality regularly as it can change. After installation, test outgoing filtered water quality regularly to ensure 

system is installed correctly and meeting your treatment needs, especially if your filter’s incoming water or 

plumbing system may have high contaminant levels. Actual performance may vary depending on your local 

water and plumbing conditions and water consumption patterns.

•  DO NOT 

use product if it has been hit, dropped, or damaged. 

• 

Before using, flush any new filter cartridge with water according to the Performance Data Sheet. In addition, 

flush the cartridge whenever the system has not been used for more than 72 hours.

 

•  REPLACE FILTER CARTRIDGE 

no later than every 6 or 12 months. If the rated gallon capacity is reached or a 

noticeable reduction in flow rate, change in odor or taste occurs before 6 or 12 months of use, then replace 

filter promptly. Failure to replace filter cartridge according to these instructions may result in failure of filter to 

reduce contaminants as designed AND/OR property damage due to water leakage or flooding. 

To reduce the risk associated with choking: 

•  DO NOT 

allow children under 3 years of age to access small parts.

NOTICE:

Read entire product manual. Failure to follow all product instructions may lead to property damage due 

to water leakage or flooding. Contact a licensed plumber if you are unsure about any of the following 

instructions: 

•  System installation and use must comply with all state and local regulations and plumbing codes. 
•  Water Supply Pressure: If your water supply pressure is higher than 80 psi, you must install a pressure reducing 

valve before installing system. 

•  Water Hammer: if water hammer conditions may occur, you must install a water hammer arrester. 
•  Backflow prevention: If a backflow prevention device is installed on a water system, you must install a device 

for controlling pressure due to thermal expansion. 

•  Booster Pump: if a booster pump is installed on a water system, you must (a) maintain and inspect the attached 

pressure switch regularly in accordance with the booster pump manufacturer’s instructions; and (b) install an 

appropriate pressure reducing valve, and maintain and inspect the valve regularly. 

•  When mounting the system, pick a location where (a) the filter will not be struck by other items, (b) no 

equipment, electrical wires or pipes will be in the path of your drilling or tools, and (c) the fasteners will support 

the weight of the system when full of water.

•  Install only on cold water supply line. 

DO NOT

 install where ambient temperatures or water temperatures may 

exceed 100°F (37.8°C). 

DO NOT

 install in direct sunlight or outdoors. 

•  Protect from freezing. Remove filter cartridge if temperature may drop below 40°F (4.4°C).

•  DO NOT

 install with rigid piping (such as copper, aluminum, stainless steel, chrome plated, or anodized tubing). 

•  Use compatible flexible tubing with appropriate connections (such as PEX tubing, PE tubing, PP tubing). Avoid 

twisting during installation. 

•  DO NOT

 install or use if a collet or any other component is missing. Contact 1-866-990-9785 or your local 

distributor. 

•  DO NOT

 use product if it has been hit, dropped, or damaged.

Содержание HF05-MS

Страница 1: ...Manifold Systems Note Installer please leave with owner operator For all BREW BEV ICE HF High Flow Series Water Filtration Systems Register your system and sign up for reminders at www 3m com FSfilte...

Страница 2: ...Service System and Replacement Cartridge Retain these instructions for future reference Intended Use and Product Selection The 3M High Flow Series Water Filtration System filters drinking water for y...

Страница 3: ...ce filter cartridge according to these instructions may result in failure of filter to reduce contaminants as designed AND OR property damage due to water leakage or flooding To reduce the risk associ...

Страница 4: ...ation et en la comparant aux capacit s du syst me nonc es dans la fiche technique de performances Le syst me de filtration d eau 3MMC de la s rie High Flow doit tre install et entretenu comme indiqu d...

Страница 5: ...guli rement le pressostat raccord conform ment aux instructions du fabricant de la pompe de surpression et b installer une vanne de r duction de la pression appropri e et entretenir et inspecter la v...

Страница 6: ...er t dlichen Verletzungen f hren kann HINWEIS Weist auf eine Situation hin die wenn sie nicht vermieden wird zu Sachsch den f hren kann ACHTUNG Lesen Sie das Produkthandbuch vollst ndig Die Nichtbeach...

Страница 7: ...lter nicht mit anderen Objekten in Kontakt kommt b sich keine Ger te elektrischen Leitungen oder Rohre im Weg Ihres Bohrers oder anderer Werkzeuge befinden und c die Befestigungselemente das Gewicht d...

Страница 8: ...esioni personali da esposizione a contaminanti e o danni alla propriet dovuti a perdite d acqua o allagamenti NON usare con acqua microbiologicamente non sicura o di qualit sconosciuta senza un adegua...

Страница 9: ...n rame alluminio acciaio inossidabile cromati o anodizzati Utilizzare tubi flessibili compatibili con connessioni appropriate come tubi in PEX PE o PP Evitare di attorcigliare i tubi durante l install...

Страница 10: ...la calidad del agua filtrada con regularidad para asegurarse de que el sistema est instalado correctamente y satisfaga sus necesidades de tratamiento sobre todo si el agua que ingresa en el filtro o...

Страница 11: ...no sigue las instrucciones anular la garant a Deje un espacio de un m nimo de 3 7 62 cm debajo del filtro para facilitar el cambio del filtro Veiligheidsinformatie Lees en volg alle productinstructie...

Страница 12: ...de filter onmiddellijk als de nominale capaciteit in gallons is bereikt of als er binnen 6 tot 12 maanden een waarneembare verandering van de geur of de smaak optreedt Het niet vervangen van de filte...

Страница 13: ...te controleren of het systeem op de juiste wijze functioneert filtercartridges op tijd zijn vervangen en alle leidingen en koppelstukken goed vastzitten en lekkagevrij zijn Ga voor de prestatiegegeven...

Страница 14: ...14 72 6 12 6 12 3 552 kPa 80 psi a b a b c 100 F 37 8 C 40 F 4 4 C PEX PE PP 1 866 990 9785 6 12...

Страница 15: ...15 3M com waterquality 3M 1 866 990 9785 3M 1 866 990 9785 3M com waterquality 3 7 62 cm 3M 3M NSF ANSI 42 53 3M 72 6 12 6 12 3...

Страница 16: ...16 80 psi a b a b c 100 F 37 8 C 40 F 4 4 C PEX PE PP 1 866 990 9785 6 12 3M com waterquality 1 866 990 9785 3M 1 866 990 9785 3M 3M com waterquality 3 7 62 cm...

Страница 17: ...Kapazit tsraten f r alle Filterkartuschen Collegamenti di ingresso e uscita Le cartucce del sistema di filtrazione dell acqua a collettore della serie High Flow servono a fornire acqua di alta qualit...

Страница 18: ...ren geraden Schnitt aus Tritt an einer Steckverbindung eine Undichtigkeit auf ist dies gew hnlich auf ein Problem mit der Leitung zur ckzuf hren Behebung 1 Entlasten Sie den Druck 2 L sen Sie die Leit...

Страница 19: ...in shape with three internal tabs bottom center and top Tab interfaces with windows in the manifold head near each connection port Proper use of the connectors is shown in the figure above 1 Insert fi...

Страница 20: ...trale nell apertura corrispondente 4 Infine spingere la linguetta superiore nell apertura corrispondente C mo usar el accesorio de entrada salida y los clips de sujeci n Los accesorios de entrada sali...

Страница 21: ...de agua de entrada est cortado antes de la instalaci n Stap 1 Haal het systeem uit de verpakking en controleer de onderdelenlijst pagina s 30 33 OPMERKING controleer voordat u met de installatie begin...

Страница 22: ...issern Sie sich dass der Montageort und die Befestigungselemente das Gewicht des Systems tragen k nnen wenn dies installiert und voller Wasser ist Passo 3 Selezionare i serraggi non inclusi e gli stru...

Страница 23: ...tween the bracket holes or by using the bracket itself tape 5 Marquez les emplacements des organes de serrage soit en mesurant la distance entre les orifices du support soit en vous servant du support...

Страница 24: ...p 7 Allow 1 4 3 8 6 10 mm of each fastener to protrude from the surface tape 7 Laissez chaque organe de serrage d passer de 6 10 mm de 1 4 3 8 po de la surface de montage Schritt 7 Lassen Sie 6 10 mm...

Страница 25: ...die Halterung an den Befestigungselementen an Passo 8 Installare la testa e la staffa sui serraggi Paso 8 Instale el cabezal y el soporte sobre los sujetadores Stap 8 Installeer de kop en de houder op...

Страница 26: ...ss besteht nur aus einem Stutzen Die Anweisungen f r die Sicherungsclips befinden sich auf Seite 20 Paso 10 Installare i raccordi di ingresso posteriore sinistro e di uscita anteriore destro sul colle...

Страница 27: ...m Anschlag nach rechts drehen ist ein Klickger usch h rbar Sp len Sie neu installierte Kartuschen gem den Anweisungen in der Sp ltabelle auf Seite 38 41 Passo 11 Rimuovere il tappo sanitario dalla car...

Страница 28: ...erumfang der Kartuschen enthalten Das System ist jetzt einsatzbereit Procedura di avviamento dell attrezzatura 1 Aprire l acqua in entrata al sistema 2 Pressurizzare il sistema ruotando lentamente la...

Страница 29: ...er 3M com waterquality oder wenden Sie sich unter 1 866 990 9785 an 3M Sostituzione Della Cartuccia Per una corretta manutenzione del sistema di filtrazione necessaria la sostituzione ordinaria delle...

Страница 30: ...A N A HF30 MS 5615111 1 67 gpm 6 3 lpm N A N A HF35 MS 5615211 1 67 gpm 6 3 lpm N A N A HF40 5613303 2 1 gpm 7 9 lpm N A N A HF45 5613307 2 1 gpm 7 9 lpm N A N A HF40 S 5613305 2 1 gpm 7 9 lpm N A N A...

Страница 31: ...9 lpm Chloramine 3 5 gpm 13 25 lpm CTO N A N A HF65 S SR 5637207 HF65 S SR5 5613451 5 gpm 18 9 lpm N A N A HF90 5613503 5 gpm 18 9 lpm N A N A HF95 5613507 5 gpm 18 9 lpm N A N A HF90 S 5613505 5 gpm...

Страница 32: ...ip O ring 7 70 0202 2973 1 6225005 Inlet fitting kit 8 70 0202 2974 9 6225006 Outlet fitting kit 9 N A N A 3 4 x 3 4 ball valve 10 70 0203 5424 0 8500556 Pressure Gauge optional 11 Inquire 5617501 Ret...

Страница 33: ...7 70 0202 2973 1 6225005 Inlet fitting kit 8 70 0202 2974 9 6225006 Outlet fitting kit 9 N A N A 3 4 x 3 4 ball valve 10 70 0203 5424 0 8500556 Pressure Gauge optional 11 Inquire 5617501 Retainer Kit...

Страница 34: ...produit 3M est appropri pour une application particuli re et son efficacit y compris l eau locale et l tat de la plomberie Le client est tenu de d terminer si un produit 3M respecte les exigences des...

Страница 35: ...r geltend gemachten Rechts oder Billigkeitstheorie wie z B durch Garantie Vertrag Fahrl ssigkeit oderverschuldensunabh ngige Haftung Selezione e utilizzo del prodotto Molti fattori possono influenzare...

Страница 36: ...een 3M product al dan niet geschikt is voor een bepaalde toepassing en welke prestaties het product levert wordt bepaald door tal van factoren waaronder de lokale waterkwaliteit en de afvoeromstandigh...

Страница 37: ...37 3M 3M 3M 3M 1 3M 3M 3M 3M 3M 866 990 9785 3M 3M 3M 3M 3M 3M 1 3M 3M 3M 3M 3M 866 990 9785 3M 3M...

Страница 38: ...2 mins High Flow Series Triple 3XX Manifold 3 3 gpm 11 4 lpm Flush 6 0 gallons 22 7 liters through cartridge s before use flush approx 2 mins Flush Table HF20 S1 HF20 MS1 HF25 S1 HF25 MS1 Head Manifo...

Страница 39: ...e s before use flush approx 2 mins High Flow Series Triple 3XX Manifold 3 5 gpm 18 9 lpm Flush 10 5 gallons 39 75 liters through cartridge s before use flush approx 2 mins Flush Table HF401 HF40 S1 HF...

Страница 40: ...h 9 0 gallons 34 1 liters through cartridge s before use flush approx 2 mins High Flow Series Triple 3XX Manifold 3 6 6 gpm 25 lpm Flush 13 5 gallons 51 1 liters through cartridge s before use flush a...

Страница 41: ...h 28 0 gals 106 0 liters through cartridge s before use flush approx 2 mins High Flow Series Triple 3XX Manifold 3 21 gpm 79 5 lpm Flush 42 0 gallons 159 0 liters through cartridge s before use flush...

Страница 42: ...42...

Страница 43: ...43...

Страница 44: ...emark of Water Quality Association Please recycle Printed in USA 2021 3M Company All rights reserved 34 8727 1412 5 3M Purification Inc 3M Separation and Purification Sciences Division 400 Research Pa...

Страница 45: ...1 Date 10 28 21 Printed Colors Front Printed Colors Back Match Colors This artwork has been created as requested by 3M 3M is responsible for the artwork AS APPROVED and assumes full responsibility for...

Отзывы: