3M Touch Systems Proprietary Information
16
3M Dynapro ET 3170 Terminal User’s Installation Guide
5.
Using a 1/8-inch flathead screwdriver, turn the terminal block’s screw
clockwise until the neutral cable wire is firmly attached to the terminal.
Figure 4: Connecting AC power cable wires to connectors
6.
Repeat (3) and (4) for the ground and line cable wires.
7.
Tighten the screws on the terminal block to a torque of 10 inch-pounds.
8.
Fasten a cable tie around the three wires at about one inch from the terminal
connector (Figure 5).
Figure 5: Connecting AC power: Fixed field wiring
9.
Slide the insulator up the power cable, positioning it so that one end of the
insulator is flush with the terminal connector and the other end overlaps the
power cable jacket by at least one inch.
10.
To prevent the insulator from moving up or down the cable, secure the
insulator to the chassis of the terminal using a cable tie or other equivalent
securing device.
- N/L2 NEUTRAL
- GROUND
- L/L1 LINE
31013
Terminal block
Cable tie
Tie mount
Cable tie
(inside insulator)
Insulator
Fuse
Содержание Dynapro ET 3170 Terminal Series B
Страница 6: ......
Страница 10: ......
Страница 14: ......
Страница 18: ......
Страница 22: ......
Страница 26: ......
Страница 30: ......
Страница 32: ......
Страница 34: ......
Страница 36: ......
Страница 44: ......
Страница 88: ......
Страница 98: ......
Страница 103: ......
Страница 106: ......
Страница 107: ......
Страница 113: ......
Страница 115: ......
Страница 117: ......