manualshive.com logo in svg
background image

Quick Start Guide

3M™ Model 711 Digital Conversion Station

©3M June 2000

3

EMC Compliance USA and Canada

FCC Radio Frequency Rules and Regulations

This equipment has been tested and found to comply with the limits for a Class A device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can emit radiated radio frequency energy
and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to correct the interference
at his own expense.

FCC Intentional Radiator Certification

This equipment contains an intentional radiator approved by the FCC under the FCC ID number
shown above. This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.

NO MODIFICATIONS. Modifications to this device shall not be made without the written
consent of The 3M Company. Unauthorized modifications may void the authority granted under
Federal Communications Commission Rules permitting the operation of this device.

Industry Canada Radio Frequency Rules and Regulations

This Class A digital apparatus meets all requirements of the Canadian Interference-Causing
Equipment Regulations.

Cet appareil numerique de la classe A respecte toutes les exigences du Reglement sur le
materiel brouilleur du Canada.

CANADA:

Operation is subject to the following two conditions: (1) this device may not cause interference,
and (2) this device must accept any interference received, including interference that may
cause undesired operation of the device.

FCC ID:

Содержание Charge Analyzer 711

Страница 1: ...Brand Digital Identification D1 Tag Only 3M Brand Digital Identification D1 Tags are to be used with the Model 711 Digital Conversion Station The use of other materials could lead to poor performance...

Страница 2: ...on Conversion Station Possibility of unsafe handling and disposal of components of the Conversion Station Any batteries circuit boards etc must be handled and disposed of in accordance with local dis...

Страница 3: ...d by the FCC under the FCC ID number shown above This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interferenc...

Страница 4: ...711 Digital Conversion Station Quick Start Guide 4 3M June 2000 EMC Compliance Europe Conformity assessment and marking requirements to be determined Conformity assessment in progress at time of publ...

Страница 5: ...harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CANADA __________ This Class A digital apparatus meets all requi...

Страница 6: ...the machine from the shipping crate using a ramp Be very careful when moving the machine down the ramp and onto the floor Before You Start Setting up the Conversion Station DO NOT PLUG THE CONVERSION...

Страница 7: ...inside the front doors Figure 1 Unopened Crate 2 Remove the side of the crate The side you remove will be used as a ramp 3 Set the ramp onto the pallet so that the pins on one end of the ramp align w...

Страница 8: ...achine 6 The plastic covering on the machine is secured with tape Grasp the tape and plastic covering and slowly pull the machine out of the shipping crate Figure 3 Figure 3 Removing Conversion Statio...

Страница 9: ...the left front door pull down on the pins to release the door Figure 5 Figure 5 Releasing upper and lower pin on the left front door 5 Unpack the support mast with scanner and monitor Figure 6 Figure...

Страница 10: ...nner cable into the mast hole Figure 7 Figure 7 Inserting black scanner cable into mast hole 7 Insert the gray video cable into the mast hole Figure 8 a Position the gray video cable in the mast hole...

Страница 11: ...in mast hole slot a The bottom of the support mast has a notch With the notch facing the front of the unit insert the support mast in the mast hole The notch fits over a pin located inside the cabine...

Страница 12: ...IS OFF 9 Connect the gray video cable 50 pin connector to the connector located in the back of the monitor Figure 11 a Push any excess cable down inside the cabinet Figure 11 Gray video cable connect...

Страница 13: ...connector on the computer e Connect the AC power cord to the AC power connector located on the outside lower right hand side of the Conversion Station Figure 13 Figure 13 AC power cord connected 11 En...

Страница 14: ...on the monitor 5 The computer initializes and displays the main conversion screen 6 If power does not come on check that the circuit breaker located inside the cabinet on the lower right side is in th...

Страница 15: ...Up Position 3 Release the stop lever so that it drops down into a horizontal straight out position Figure 17 4 Remove the two plastic core inserts from the supply roll shaft Figure 17 Figure 17 Relea...

Страница 16: ...roll Figure 19 Figure 19 Leader Coming Off Left Side Threading Leader Up Under Curved Spring Plate 6 Thread the leader of the D1 roll of tags up through the tag feed area under the curved steel sprin...

Страница 17: ...ader pass on the side of the guide plate toward the take up spool Figure 21 Figure 21 Putting a Slight Upward Bend in Leader 9 Push the leader back down into the slot of the tag feeder opening on the...

Страница 18: ...a under the curved steel spring plate b back down into the slot of the tag feeder opening on the same side of the wire spring c down toward the take up spool on the side of the guide plate toward the...

Страница 19: ...ition the slot rotate the take up spool by pushing down on the tag dispenser switch until the crimp slot is at or near the top Figure 26 Guiding Leader Around Take Up Spool b Rotate the take up spool...

Страница 20: ...Figure 28 Figure 28 Rotating the Stop Lever to Down Position 14 Place the tag dispenser switch in the ON up position Figure 29 Figure 29 Setting the Tag Dispenser Switch to ON 15 The dispenser automat...

Страница 21: ...on Station 3M June 2000 21 Note If the leader is excessively long the motor may stop automatically Restart the motor by turning the dispenser switch OFF middle position and then ON again Normal operat...

Страница 22: ...op down list box select the appropriate button Use the mouse or touch the screen to make a selection Use the keyboard to type in the branch name Branch ID To add a new branch ID or to edit or remove a...

Страница 23: ...r slightly above the surface of the read write area on the left side of the work surface The audible beep or tag placement sound indicates that the tag has been successfully programmed The touch scree...

Страница 24: ...mentation The Digital Conversion Station has extensive online documentation that contains procedures troubleshooting and reference material The online operator s documentation should be reviewed as th...

Страница 25: ...person teams Use of two person teams reduces errors and improves productivity One team member can move items while the other can do the actual conversion Frequent task switching keeps both team membe...

Страница 26: ...n Station software allows staff to make limited configuration changes The library administrator and computer support staff can make additional advanced configuration changes Password Information All i...