6-2
9.
Clock does not display
correct time of day.
A.
Electrical outlet operated by switch.
A.
Use electrical outlet not controlled by switch.
B.
Incorrect voltage or frequency (Hz).
B.
Replace timer with one of correct voltage and frequency (Hz)
(Contact Dealer).
C.
Power outages.
C.
Reset clock.
10.
No water fl ow display
when water is fl owing.
A.
Bypass valve in bypass.
A.
Shift bypass valve to not-in-bypass position.
B.
Meter probe disconnected or not fully connected
to meter housing.
B.
Fully insert probe into meter housing.
C.
Restricted meter turbine rotation due to foreign
material in meter.
C.
Remove meter housing, free up turbine and fl ush with clean
water. Turbine should spin freely, if not, replace meter.
D.
Problem with meter probe.
D.
Replace harness.
E.
Problem with circuit board.
E.
Replace timer.
11.
Control will not
regenerate automati-
cally or when button is
pressed.
A.
Electrical cord or transformer unplugged.
A.
Connect power.
B.
Problem with motor.
B.
Replace motor.
12.
Control regenerates at
wrong time of day.
A.
Power outages.
A.
Reset clock to correct time of day.
B.
Clock set incorrectly.
B.
Reset clock to correct time of day.
13.
Intermittent or irregular
brine draw.
A.
Low water pressure.
A.
Set pump to maintain 20 psi at softener.
B.
Possible problem with injector.
B.
Replace injector and cap.
14.
System using more
or less salt than salt
control is set for.
A.
Inaccurate setting.
A.
Make correct setting.
B.
Foreign matter in controller causing incorrect fl ow
rates.
B.
Remove salt controller and fl ush out foreign matter. Manually in-
dex control to brine/slow rinse and allow unit to proceed through
complete regeneration.
C.
Problem with controller.
C.
Replace part.
15.
No conditioned water
after regeneration
A.
No salt in brine tank.
A.
Add salt to brine tank.
B.
Injector plugged.
B.
Clean injector and injector screen.
C.
Air check valve closes prematurely.
C.
Put control momentarily into refi ll to free air check. Replace or
repair air check if needed.
D.
Unit did not regenerate.
D.
Check for power.
16.
Control will not regen-
erate automatically but
will regenerate when
button is pushed.
A.
If water fl ow display is not operative, refer to
Problem 10.
A.
Same as Problem 10.
B.
Problem with circuit board.
B.
Replace timer.
C.
Incorrect hardness and capacity settings.
C.
Set to correct values.
17.
Run out of soft water
between regenerations
A.
Improper regeneration.
A.
Repeat regeneration, making certain that correct salt dosage is
used.
B.
Incorrect salt settings.
B.
Set control to proper level. See Specifi cations.
C.
Incorrect hardness.
C.
Set to correct values.
D.
Water hardness has increased.
D.
Set hardness to new value.
E.
Restricted meter turbine rotation due to foreign
material in meter.
E.
Remove water housing, free up turbine and fl ush with clean
water. Turbine should spin freely; if not, replace meter.