3-4
The following tables show the estimated salt amount for each setting, as well as the estimated capacity of that salt setting for each resin amount.
Media Volume
Salt Setting
Total Salt Amount per Regeneration (lbs)
1.0
L (Low)
3.5
S (Standard)
9
H (High)
15
1.5
L (Low)
5.25
S (Standard)
13.5
H (High)
22.5
2.0
L (Low)
7
S (Standard)
18
H (High)
30
3.0
L (Low)
10.5
S (Standard)
27
H (High)
45
L = Low salt, approximately 5 lbs. per cu. ft. of media
S = Standard salt, approximately 9 lbs. per cu. ft. of media
H = High salt, approximately 15 lbs. per cu. ft. of media
To program the salt amount, press the SET button to enter the change mode. The L default will begin to fl ash. Use the UP and DOWN arrow keys to scroll through
the three settings. Press the SET button to enter the amount.
• Capacity
The controller is designed to estimate capacity of the system by multiplying the initial resin/media volume by the regenerant amount programmed in under “Amount
of regenerant used per regeneration.”
An estimated total system capacity is displayed in kilograins (kilograms CaCO
3
) that could be removed by the fully regenerated media bed. This value is derived by
standard water treatment industry norms. The system capacity is displayed merely for the installers reference when determining regeneration frequency.
NOTE: Capacity is the result of the amount of media in the tank and the salt setting. The default capacity will be changed by selecting a different salt setting.
• Hardness setting
The hardness setting is set in grains per gallon (CaCO
3
). The hardness is divided into the total capacity setting, giving a total volume of water that can be conditioned
before a regeneration is needed. To set, press SET when P8 is displayed, and use the UP or DOWN buttons to increment. Press SET again to accept the setting.
HISTORY
This level displays settings and usage information that can be used to diagnose and troubleshoot the system.
To enter the history level:
Action
Key
Duration
Display
Enter data mode
DOWN arrow and SET
5 sec.
Value for H0
Scroll through history
UP and DOWN arrows P/R
P/R
Next history value
Reset value to factory default
SET
5 secs. with value is displayed
Original factory default
Figure 23