SAFETY INFORMATION

Read, understand, and follow all safety information contained in these instructions prior to installation and use of the Aqua-Pure

®

 AWS Series Residential Water Softener. 

Retain these instructions for future reference.  Failure to follow installation, operation and maintenance instructions may result in property damage and will void warranty.

Intended use:

The Aqua-Pure AWS Series Residential Water Softener is intended for use in softening water in homes and has not been evaluated for other uses.  The system must be 
installed indoors near the point of entry of a home water line, and be installed by qualifi ed professional installers according to these installation instructions.

EXPLANATION OF SIGNAL WORD CONSEQUENCES

 WARNING

Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury and/or property damage.

 CAUTION

Indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate injury and/or property damage.

CAUTION

Indicates a potentially hazardous situation, which, if not avoided, may result in property damage.

 WARNING

To reduce the risk associated with choking: 

• 

Do not

 allow children under 3 years of age to have access to small parts during the installation of this product.

To reduce the risk associated with ingestion of contaminants:

• 

Do not 

use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

To reduce the risk of physical injury: 

•  Shut off inlet water supply and depressurize system as shown in manual prior to service.

To reduce the risk associated with a hazardous voltage:

•  If the home electrical system requires use of the cold water system as an electrical safety ground, a jumper must be used to ensure a suffi cient ground connection across 

the fi lter installation piping — refer installation to qualifi ed personnel.

• 

Do not

 use the system if the power cord is damaged — contact qualifi ed service personnel for repair.

To reduce the risk associated with back strain due to the heavy weight of the various system components:

•  Follow safe lifting procedures.

 

CAUTION

To reduce the risk associated skin, eye, and respiratory tract irritation from gravel and fi lter media during installation:

•  Gravel and several types of fi lter media may be used in this product, depending upon the application.  During installation, dust may cause irritation to skin, eyes, and 

respiratory tract.

•  Utilize a NIOSH-approved dust fi lter mask, protective gloves, and appropriate eye protection when handling and pouring gravel and fi lter media.
•  To request an MSDS relating to this product, call 203-238-8965 or go to www.3M.com , select country, and use the search engine to search MSDS.  For emergen-

cies, call 800-364-3577 or 651-737-6501 (24 hours).

CAUTION

To reduce the risk associated with property damage due to water leakage:

• 

Read and follow 

Use instructions before installation and use of this water treatment system.

•  Installation and use 

MUST

 comply with existing state or local plumbing codes.

• 

Protect from freezing

, relieve pressure and drain system when temperatures are expected to drop below 33°F (0.6°C).

• 

Do not

 install on hot water supply lines.  The maximum operating water temperature of this fi lter system is 110°F (43.3°C).

• 

Do not

  install systems in areas where ambient temperatures may go above 110° F (43.3° C).

• 

Do not

 install if water pressure exceeds 125 psi.  If your water pressure exceeds 80 psi (552 kPa), you must install a pressure limiting valve. Contact a plumbing 

professional if you are uncertain how to check your water pressure.

• 

Do not

 install where water hammer conditions may occur.  If water hammer conditions exist you must install a water hammer arrester.  Contact a plumbing profes-

sional if you are uncertain how to check for this condition.

•  Where a backfl ow prevention device is installed on a water system, a device for controlling pressure due to thermal expansion must be installed.
• 

Do not

 use a torch or other high temperature sources near fi lter system, cartridges, plastic fi ttings or plastic plumbing.

•  On plastic fi ttings, never use pipe sealant or pipe dope. 

Use PTFE thread tape only,

 pipe dope properties may deteriorate plastic.

•  Take care when using pliers or pipe wrenches to tighten plastic fi ttings, as damage may occur if over tightening occurs.
• 

Do not

 install in direct sunlight or outdoors.

•  Mount system in such a position as to prevent it from being struck by other items used in the area of installation.
•  Ensure all tubing and fi ttings are secure and free of leaks.
• 

SHUT OFF FUEL OR ELECTRIC POWER SUPPLY TO WATER HEATER

 after water is shut off.

• 

Do not

 install system where water lines could be subjected to vacuum conditions without appropriate measures for vacuum prevention.

• 

Do not

 apply heat to any fi tting connected to bypass or control valve as damage may result to internal parts or connecting adapters.

•   Install on a fl at/level surface. It is also advisable to sweep the fl oor to eliminate objects that could pierce the media tank.

To reduce the risk associated with property damage due to plugged water lines:

•  Pay particular attention to correct orientation of control valve. Water fl ow should match arrow on control valve. The Inlet and Outlet of other water treatment 

equipment products will vary depending on the control valve brand used.

IMPORTANT NOTES

• 

Failure to follow instructions will void warranty.

Содержание Aqua-Pure AWS100M

Страница 1: ...ALLATION AND OPERATING INSTRUCTIONS AWS SERIES RESIDENTIAL WATER SOFTENERS MODELS AWS100M AWS150M AWS200M AWS300M INSTR2198 0911 Installer please leave with homeowner Homeowner retain for future refer...

Страница 2: ......

Страница 3: ...To request an MSDS relating to this product call 203 238 8965 or go to www 3M com select country and use the search engine to search MSDS For emergen cies call 800 364 3577 or 651 737 6501 24 hours CA...

Страница 4: ......

Страница 5: ...ts power source MECHANICAL 1 Do not use petroleum based lubricants such as petroleum jelly oils or hydrocarbon based lubricants Use only 100 silicone lubricants 2 Take care when using pliers or pipe w...

Страница 6: ...ts Do not get primer or solvent on o rings nuts or the valve IMPORTANT NOTE If sediment is present the installation of a sediment pre filter is recommended Even if sediment is not currently present or...

Страница 7: ...R OPTIONAL SOFT WATER INCOMING WATER FILTERED WATER FILTERED PUBLIC WATER INSTALLATION CHECK VALVE WASTE DRAIN WASTE DRAIN CAUTION To reduce the risk associated with property damage due to water leaka...

Страница 8: ...ficient ground connection across the water softener installation piping refer installation to qualified personnel The control valve allows for 1 2 connection for use as a drain line connection CAUTION...

Страница 9: ...3 This will allow the unit to fill slowly from the bottom up reducing air entrapment Allow unit to fill slowly failure to do so could result in loss of resin to the drain Once a steady stream of wate...

Страница 10: ...ndicates which regeneration cycle is currently in progress See Figure 5 CAMSHAFT FRONT END The corresponding slot for the number is positioned at the optical sensor which is approximately 90 degrees o...

Страница 11: ...e cursors will be displayed to indicate which day will be programmed into the controller 5 PM indicates that the time displayed is between 12 00 noon and 12 00 midnight there is no AM indicator PM ind...

Страница 12: ...n memory Also used together with the arrow buttons 3 UP arrow Generally used to scroll up or increment through a group of choices 4 Regenerate Used to command the controller to regenerate Also used to...

Страница 13: ...glass icon will be displayed Repeat this process for each cycle until the system is back into the treated water mode IMPORTANT NOTES When the controller gets to cycle C4 Pause cycle there may be a sli...

Страница 14: ...neration at the next set time of regeneration Push the REGEN button once The recycle symbol will be flashing on the display Figure 10 Push the REGEN button again to cancel For an immediate regeneratio...

Страница 15: ...owly escaping from the valve drain line B When all of the air has been purged from the media tank water begins to flow steadily from the drain line open the main supply valve all of the way This will...

Страница 16: ...alve to the brine draw position Hold the REGEN button down for 5 seconds The controller will begin a manual regen and advance the control valve to the cycle C1 Backwash Press the SET and UP button to...

Страница 17: ...at the factory These default settings will work for most applications The controller menu has three levels Basic This level is easily accessed by the user The settings can be changed and saved as lon...

Страница 18: ...ttons to increase decrease the time Push SET to enter the selection Days of the week The day of the week does not have a default setting It is entered at Power up To change the current day push SET wh...

Страница 19: ...sible the dealer installer has three salt amount options to choose from These are set up to give the installation the maximum performance based on the inputs by the dealer installer The three salt opt...

Страница 20: ...capacity is displayed in kilograins kilograms CaCO3 that could be removed by the fully regenerated media bed This value is derived by standard water treatment industry norms The system capacity is di...

Страница 21: ...in gallons 0 65536 gallons H11 Average usage for Thursday in gallons 0 65536 gallons H12 Average usage for Friday in gallons 0 65536 gallons H13 Average usage for Saturday in gallons 0 65536 gallons...

Страница 22: ...replacing the controller use the same model or some functions may not work This is an electronic controller that is programmable and uses input output signals To remove control module 1 Disconnect po...

Страница 23: ...t or the motor When the controller is powered up the camshaft will be rotated to the home position OPTICAL SENSOR The optical sensor is mounted to the top plate The camshaft cup rotates through the se...

Страница 24: ...fset enable the service person to view the number at the top of the cup and deter mine which slot is at the optical sensor IMPORTANT NOTE If any part of the camshaft is broken or damaged the camshaft...

Страница 25: ...e wires can become tangled in the camshaft 1 Depending on which harness is being installed plug the connector into the motor or turbine 2 Route the harness through the opening at the back of the top p...

Страница 26: ...ing 2 Position yourself on the spring side of the valve discs 3 Position the spring over the valve body close to final position The wide spring segments will be located at the wide valve discs The cur...

Страница 27: ...ved to reassemble the top plate IMPORTANT NOTE Follow the procedure to engage the screws with the existing threads If the same threads are not used the holding power of the screw is lost Under pressur...

Страница 28: ...remove injector screen and injector cap 5 Clean injector screen using a fine brush Flush under running water until clean 6 Using a needle nose pliers pull injector straight out 7 Flush water into the...

Страница 29: ...ir out of the system 10 The system will require the startup procedure to be performed in order to operate appropriately CHECK TURBINE OPERATION After the turbine has been cleaned verify that the turbi...

Страница 30: ...the display under the day of the week When the correct day is flagged push SET The controller is ready to operate The media tank should be ready for operation 5 Hold the REGEN button on the controlle...

Страница 31: ...Working Pressure psi 20 125 20 125 20 125 20 125 Min Max Operating Temperature F 40 110 40 110 40 110 40 110 Max Flow Rate gpm to Drain During Regeneration Cycle 1 6 2 5 2 5 4 8 Amount of High Capaci...

Страница 32: ...ts C If motor continues to rotate indefinitely replace the following components in this order Optical sensor Wire Harness Motor Controller 4 Brine tank overflow A Uncontrolled brine refill flow rate A...

Страница 33: ...4 System using more or less salt than salt control is set for A Inaccurate setting A Make correct setting B Foreign matter in controller causing incorrect flow rates B Remove salt controller and flush...

Страница 34: ...0X 13000X 13000X 13000X 6 Brine Tank Complete BT1534X BT1534X BT1534X BTCS33BK 7 Overflow Fitting BT16 BT16 BT16 BT16 8 Brine Tank Shell w Cover BT1534L BT1534L BT1534L BT1833BK 9 Brine Well w Cap BT1...

Страница 35: ...e Assembly 8 1000226 Screen Cap Assembly w O ring Injector High Efficiency Options 9 1030410 1030412 1035736 G Injector High Efficiency Tan J Injector High Efficiency Lt Blue L Injector High Efficienc...

Страница 36: ...remedy and 3M Purification Inc s exclusive obligation Warranty Period One 1 year on the entire product unit Five 5 years on the mineral tank only does not include internal component parts Five 5 year...