3DGence ONE | 55
version 1.0/08.2017
NOTE:
Negative values of Z offset should never exceed the thickness of first printing layer!
Pressure:
Sensitivity of autocompensation measurement on Z-axis allows determining the value of contact force for print
head while measuring the height between the head and the work table. Measurement sensitivity can be adjusted in the
range between 20 (0.5g) and 120 (4g). When using materials with higher fluidity, it may be necessary to increase the
contact force to reduce the risk of incorrect measurement caused by leaning of the head against the extruding material.
When starting the print, these incorrect readings may cause lifting up of the head as a result of adding the thickness of
material leaking under the head (holding the head up) in the process of height calculation.
Position of measurement
is another important parameter in the process of autocompensation. This parameter can be
regulated by selecting Probe position in Calibration main menu.
By editing values in
Pos X
and Pos
Y
, the point of autocompensation can be changed - respectively for X and Y axes of
the printer.
This option can be useful when using adhesive tapes or pads. In such a case, Z-offset should be set to correspond to the
thickness of the applied tape or pad. This parameter can be also set to negative values and as a result, the starting point
for the printout will be placed at a lower height (closer to the table).