q u i c k s t a r t g u i d e
r d m i n s t a l l a t i o n a n d r e m o v a l
28
Resin Containers
Figure 8. Resin Containers
New Containers
Before starting this procedure, make sure that the container slot is empty. If a container is present,
refer to the previous section, “Removing Empty Resin Containers,” before continuing. While
wearing protective clothing, disposable nitrile gloves, and goggles, perform the following steps:
1 Open the resin refill door until it is completely inverted.