5-10
C
HAPTER
5: P
ERFORMING
T
ROUBLESHOOTING
AND
D
IAGNOSTIC
T
ESTS
10
If you experience problems that occur only when using
the AutoLink program, display or print the AUTOLINK.LOG
file. The AUTOLINK.LOG file contains a log of all the events
that occurred during the AutoLink installation and
configuration process.
a
To display the file, type:
type autolink.log | more
b
To print the file, type:
print autolink.log
Changing the Test Setup
To change the test parameters, follow these steps:
1
Choose
Test Setup
from the
Test
menu in the main
window of the Configuration and Diagnostic Program, or
choose the
Test Setup
button in the Run Tests dialog box.
2
Press [Tab] to highlight any of the fields within the Test
Setup dialog box.
3
To change a setting in any field, follow these steps:
a
In the Group Select box, use the arrow keys to select a
test group.
For more information on the Group 2 or Group 3 tests, refer to
the appropriate sections earlier in this chapter.
b
In the Group
X
Tests box, use the arrow keys to highlight
a test. Press the [Space Bar] to enable or disable an
individual test.
c
In the Repetitions box, specify the number of times you
want to run the tests, or use the arrow keys to select the
Continuous option.
d
In the Errors box, press the [Space Bar] to select or
deselect the
Halt on Error
parameter.
4
When you are satisfied with the new test setup, select the
OK