1-6
<Sysname> display poe temperature-protection
The temperature protection is enabled.
poe disconnect
Syntax
poe disconnect
{
ac
|
dc
}
undo poe disconnect
View
System view
Parameters
ac
: Specifies the PD disconnection detection mode as
ac
.
dc
: Specifies the PD disconnection detection mode as
dc
.
Description
Use the
poe disconnect
command to configure a PD disconnection detection mode.
Use the
undo poe disconnect
command to restore the default.
The default PD disconnection detection mode is AC.
Note that change to the PD disconnection detection mode may lead to power-off of some PDs.
Examples
# Set the PD disconnection detection mode to DC.
<Sysname> system-view
[Sysname] poe disconnect dc
poe enable
Syntax
poe enable
undo poe enable
View
Ethernet port view
Parameters
None
Description
Use the
poe enable
command to enable the PoE feature on a port.
Use the
undo poe enable
command to disable the PoE feature on a port.
By default, the PoE feature on a port is enabled by the default configuration file when the device is
delivered.
Содержание 5500-EI Series
Страница 43: ...2 6 ...
Страница 76: ...1 17 ...
Страница 228: ...ii stp transmit limit 1 44 vlan mapping modulo 1 45 vlan vpn tunnel 1 46 ...
Страница 477: ...5 24 Sysname vlan 2 Sysname vlan2 service type multicast ...
Страница 503: ...2 3 System View return to User View with Ctrl Z Sysname dot1x url http 192 168 19 23 ...
Страница 519: ...iii ...
Страница 597: ...2 2 security policy server 192 168 0 1 user name format without domain ...
Страница 648: ...1 9 Examples Clear static ARP entries Sysname reset arp static ...
Страница 663: ...4 3 Sysname resilient arp interface vlan interface 2 ...
Страница 767: ...1 28 From 12 00 Jan 1 2008 to 12 00 Jun 1 2008 ...
Страница 1111: ...ii xmodem get 3 18 ...
Страница 1314: ...A 44 Z ...