1-18
# Configure Ethernet 1/0/2 to Ethernet 1/0/4 to recognize and send MSTP BPDUs in dot1s format.
<Sysname> system-view
[Sysname] stp interface Ethernet 1/0/2 to Ethernet1/0/4 compliance dot1s
stp config-digest-snooping
Syntax
z
System view, Ethernet port view:
stp config
-
digest
-
snooping
undo stp config
-
digest
-
snooping
z
System view:
stp interface interface-list config
-
digest
-
snooping
undo stp interface interface-list config
-
digest
-
snooping
View
System view, Ethernet port view
Parameters
interface-list
: Ethernet port list. You can specify multiple Ethernet ports by providing this argument in the
form of
interface-list =
{
interface-type interface-number
[
to
interface-type interface-number
] } &<1-10>,
where &<1-10> means that you can provide up to 10 port indexes/port index ranges for this argument.
Description
z
Use the
stp config-digest-snooping
command to enable the digest snooping feature. Use the
undo stp config-digest-snooping
command to disable the digest snooping feature. Configured
in system view, the setting takes effect globally; configured in interface view, the setting takes
effect on the current port only.
z
Use the
stp interface config-digest-snooping
command in system view to enable the digest
snooping feature on specific ports. Use the
undo stp interface config-digest-snooping
command in system view to disable the digest snooping feature on specific ports.
The digest snooping feature is disabled by default.
To enable the digest snooping feature successfully, you must first enable it on all the switch ports that
connect to the other manufacturer’s switches adopting proprietary spanning tree protocols and then
enable it globally.
According to IEEE 802.1s, two interconnected switches can interwork with each other through MSTIs in
an MST region only when the two switches have the same MST region-related configuration. With
MSTP enabled, interconnected switches determine whether or not they are in the same MST region by
checking the configuration IDs of the BPDUs between them. (A configuration ID contains information
such as region ID and configuration digest.)
Содержание 5500-EI Series
Страница 43: ...2 6 ...
Страница 76: ...1 17 ...
Страница 228: ...ii stp transmit limit 1 44 vlan mapping modulo 1 45 vlan vpn tunnel 1 46 ...
Страница 477: ...5 24 Sysname vlan 2 Sysname vlan2 service type multicast ...
Страница 503: ...2 3 System View return to User View with Ctrl Z Sysname dot1x url http 192 168 19 23 ...
Страница 519: ...iii ...
Страница 597: ...2 2 security policy server 192 168 0 1 user name format without domain ...
Страница 648: ...1 9 Examples Clear static ARP entries Sysname reset arp static ...
Страница 663: ...4 3 Sysname resilient arp interface vlan interface 2 ...
Страница 767: ...1 28 From 12 00 Jan 1 2008 to 12 00 Jun 1 2008 ...
Страница 1111: ...ii xmodem get 3 18 ...
Страница 1314: ...A 44 Z ...