7
Figure 4
-
3 Schematic diagram of external dimensions of threaded calorimeter41
Table 4
-
5 dimension table of threaded sensor41
Normal
diameter
Measuring tube
length L
Total length
L1
G
R
H1
H
DN10
100
194
G 3/4
R 1/2
147
284
DN15
100
194
147
284
DN20
100
208
G 1
R 3/4
147
284
DN25
100
226
G 1 1/4
R 1
147
284
DN32
100
227
G 1 1/2
R 1 1/4
152
289
DN40
100
227
G 2
R 1 1/2
162
299
4.3.1.3 Electrode material
Stainless steel 316L.
4.3.1.4 Lining material
PU, FEP.
4.3.1.5 Medium temperature
It is related to the temperature resistance of lining materials. See Appendix
B lining material performance table.
Fel! Hittar inte referenskälla.
4.3.1.6 Withstand voltage level
1.6MPa.
4.3.2 Degree of protection
IP65,IP67,IP68
4.3.3 Junction box
Cable access hole M20 x 1.5 female
The shell is made of cast aluminum alloy, and the surface is coated with pure
polyester plastic powder.