background image

operation.

1.3 Adverse Reactions

1) You should stop using the device and should consult 

with your physician if you experience adverse reactions 

from the device.

1.4 Travel Tips

The device’s lightweight, compact design makes it an 

easy travel companion. There are some travel tips for 

you:

1) If traveling outside the U.S., do not use the device if 

the electrical outlet is without AC100-240V 50Hz/60Hz.

2) Check with the carrier to confirm that the device can 

be carried and/or used on the airplane.

2 Intended Use & Indications for Use

2 Face / Face Evolution is a hand-held device for 

over-the-counter cosmetic use.

The EMS Mode is intended for facial stimulation for 

toning. 

And the Photon Infrared Mode is intended to be placed 

directly on the skin to get a nice feeling and provide 

topical heating with the temperature 41 

±2

.

3 Product Description

2 Face / Face Evolution (Model: 2 Face / Face 

Evolution) is a multifunctional comprehensive beauty 

instrument. It’s combined with the most effective two 

kinds of techniques of internationally recognized skin 

care: the EMS Mode is intended for facial stimulation 

for toning and the Photon Infrared Mode is intended to 

be placed directly on the skin to get a nice feeling. 

Novel appearance, 2 Face / Face Evolution can apply 

physical energy without damage, to stimulate personal 

cell vitality of skin, accelerate microcirculation, enhance 

oxygen supply and metabolism, and promote collagen 

generation and nutrition absorption, thus reach really 

tightening and tendering skin, whitening and relieving 

spot, delaying the aging of skin. You can enjoy the star 

SPA care of beauty salon at home.

3.1 Accessories List 

No.    Name    Quantity                 Picture

2 Face 

/ Face 

Evolution 

Device

2 Face 

/ Face 

Evolution

Gel Primer

DC 

Charging 

Adapter

User 

Manual

1

1

1

1

1

2

3

4

3.2 Function Introduction

2Face is a hand-held device for over-the-counter 

cosmetic use. 

   1) EMS Mode

The EMS Mode is intended for facial stimulation for 

toning.

   2) Photon Heating Mode

The Photon heating Mode is intended to be placed 

directly on the skin to get a nice feeling and heating 

therapy and provide topical heating with the 

temperature 41 

±2

.

7

8

Содержание Time Keeper

Страница 1: ...o current therapy to treat signs of aging and skin problems Fine Lines Wrinkles Pigmentation Fine Lines Uneven Tone Face Lift Frown Lines Breakouts Dark Circles Acne Bacteria Dark Spots FACE EVOLUTION Enhance your skin with the revolutionary Time Keeper 2Face Face Evolution ...

Страница 2: ...c Facial Stimulator 4 2 Select Mode 4 3 Adjust Intensity 4 4 Set Working time 4 5 Treatment 4 6 Switch the Photon Ionic Ultrasonic Facial Stimulator off 4 7 After Treatment 4 8 Charging 5 Maintenance 5 1 Cleaning 5 2 Trouble Shooting 5 3 Disposal of Electrical and Electronic Equipment Waste E waste 6 Service 6 1 Outside Warranty Period 7 Safety EMC Biocompatibility 8 Product Information 8 1 Specif...

Страница 3: ...dy surface Meanwhile calming the skin can make both body and skin relax and reduce the pain of skin LED WARM LIGHT THERAPY All the Red Blue and Green lights work together ONE DEVICE MULTIPLE SKINCARE SOLUTIONS The light based part of the treatment gently warms the top layer of your skin to target the most visible fine lines and enlarged pores Almost instantly the texture of your skin is improved A...

Страница 4: ...the product works and you ll be able to enjoy the best results 1 1 Warnings 1 DO NOT use over swollen infected or inflamed areas or skin eruptions e g phlebitis thrombophlebitis broken capillaries varicose veins etc 2 DO NOT use in the eye area circular muscles within the orbital rim on the temples on the mid line of the neck bone of neck or in the breast or groin area 3 DO NOT apply stimulation a...

Страница 5: ...skin which lack normal sensation 5 The long term effects of stimulation are unknown The safety of the mini device for use during pregnancy has not been established 6 A slight tingling sensation may occur while using the device Lowering the intensity may reduce or eliminate this sensation 7 The device is intended for cosmetic use on the face Any harmful consequence resulting from misuse application...

Страница 6: ...th the most effective two kinds of techniques of internationally recognized skin care the EMS Mode is intended for facial stimulation for toning and the Photon Infrared Mode is intended to be placed directly on the skin to get a nice feeling Novel appearance 2 Face Face Evolution can apply physical energy without damage to stimulate personal cell vitality of skin accelerate microcirculation enhanc...

Страница 7: ...e topical heating 41 2 When you choose PHOTON Mode Turn the unit ON by pressing the PHOTON button The first light is Green Light to show the Photon function is turned on It has low power testing function when the power is lower than 3 0Volts the green indicate light will be twinkling The Second light is RGB Light which shows the Photon therapy mode is working Adjust the Light mode to your aimed fu...

Страница 8: ...ht Indicator will automatically activate 4 Charging Indicator The Charging Indicator light is Red Green double color light when charging the light turns red and it will turn to Green when full charged 3 3 3 Working Modes There are 2 working modes and choose different programs by pressing Mode button of different times 1 2 Program Name Display Description EMS Mode Photon Mode Output the EMS Output ...

Страница 9: ...ll change At the 0 level no light will be illuminated and there are no microcurrent output At 1 level all one blue lights will be illuminated At the 2 level two blue light will be illuminated At the 3 level three blue light will be illuminated 5 The 2 Face Face Evolution Device will not contract the muscles and when used correctly the current is soft very soothing and mild 6 Remember to turn off t...

Страница 10: ...ture will slowly increase Press one time the Red light works and the RGB Light Indicator turns Red Press second time the Green light works and the RGB Light Indicator turns Green Press third time the Blue light works and the RGB Light Indicator turns Blue Press forth time the White light works and the RGB Light Indicator turns white that means all the Red Green and Blue lights work simultaneously ...

Страница 11: ...necessary use only mild dish washing soap with a damp cloth 5 2 Trouble Shooting In the event that the device fails to perform as intended the following notes will help to identify potential problems with the device and its setup 5 3 Disposal of Electrical and Electronic Equipment Waste E waste Disposal information for e waste depends on the city you are in as all regulations are local to learn ab...

Страница 12: ... certified by Heat In A Click LLC 7 Safety EMC Biocompatibility 1 This device is Class II equipment with type BF applied part The light treatment attachment and electrical muscle stimulation treatment attachment were considered as one type BF applied part It complies with Medical Electrical Safety Standards IEC 60601 1 IEC 60601 2 10 2 This device is also complied to Medical EMC Standard IEC 60601...

Страница 13: ...tact 8 kV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Electrical fast transient burst IEC 61000 4 4 2 kV for powersupply lines 1 kV for input output lines Not Applicable Not Applicable Not Applicable Mains power quality should be that of a typical commercial or hospital environment Surge IEC 61000 4 5 ...

Страница 14: ...2 5GHz Not Applicable 3 V m Portable and mobile RF communications equipment should be used no closer to any part of the 2 Face Face Evolution Model 2 Face Face Evolution including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance Where P is the maximum output power rating of the transmitter in...

Страница 15: ...elp prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the 2 Face Face Evolution Model 2 Face Face Evolution as recommended below according to the maximum output power of the communications equipment Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 150...

Страница 16: ...rm and Shape Pulsed Biphasic Modulated Square Basic Pulse Duration 60ms Pulse Frequency 8 33Hz Maximum Output Voltage 10 0 252V 500Ω 1 02V 2k Maximum Output Current 10 0 502mA 500Ω 0 510mA 2kΩ Net Charge per pulse 42 96μC 500Ω Maximum Phase Charge 33 264μC 500Ω Maximum Current Density 0 095mA cm2 500Ω The Minimum Electrode Size 2 91cm Maximum Power Density 264 05μW cm2 500Ω The Minimum Electrode S...

Страница 17: ...m sr W m sr No Symbols Description Indicates the Authorized representative in the European Community Manufacturer Protection against ingress of solids it means the volume of the solids should less than 12mm Protection against ingress of water it means the device could protected against vertical falling water drop 15 WEEE Waste Electrical and Electronic Equipment The waste products should be hand R...

Страница 18: ......

Отзывы: