Address:
320 B Percheron Road, Kyalami, Midrand, 1684
GPS Coordinates:
BirCraft
GEARED MOTORS - LINEAR ACTUATORS - CONTROLS
t:
+ (27) 011 468 1881
c:
+(27) 074 465 1744
e:
01@
BirCraft
.co.za
w:
.co.za
GUIDELINE DIMENSIONS ONLY
- Over
40 Years
of Supplying Africa -
Variable DC Speed Drives
–
Operation Manual
BADCD
12
-10 and BADCD
24
-10
Contents
Safety Precautions: .............................................................................................................................................................................................................................. 1
Specification and Model: ..................................................................................................................................................................................................................... 1
Product Characteristics: ....................................................................................................................................................................................................................... 2
Installation Requirements: ................................................................................................................................................................................................................... 2
Performance Indexes: .......................................................................................................................................................................................................................... 2
Wiring Requirements: .......................................................................................................................................................................................................................... 3
Driver Terminal Function Diagram: ...................................................................................................................................................................................................... 3
Description of control Terminal’s Functions:
EN (Enable Control) .................................................................................................................................................................................................................... 3
DIR (Direction Control) ............................................................................................................................................................................................................... 3
C E (OC Door Alarm Output) ....................................................................................................................................................................................................... 4
4. S1 S2 S3 Signal Output Terminal: ..................................................................................................................................................................................................... 4
Description of Indicator: ...................................................................................................................................................................................................................... 5
Regulation Description of Functional Potentiometer: .......................................................................................................................................................................... 5
Driver Examination steps before Charged: .......................................................................................................................................................................................... 5
Common Fault Treatment: ................................................................................................................................................................................................................... 5
Safety Precautions:
•
Installation, connection and commissioning of this device shall be carried out by professionals.
•
Do not install, remove or replace device circuit under charged circumstances.
•
Please make sure that necessary protectors are mounted between power input end of this device and power supply
(storage battery) to avoid accidents or fatal damages; Devices need to be mounted: over-current protector, fuse,
emergency switch.
•
Isolation and insulation protection between device and ground as well as devices shall be well equipped.
•
In case that charged commissioning of this device is really needed, well-insulated non-metal special screwdriver or
special commissioning tools shall be used.
•
This device shall be installed in well-ventilated environment.
•
This device shall not be directly exposed to abnormal environments with high humidity, dust, corrosive gas and intense
vibration.
Specification and Model:
PRODUCT #:
CONTINUOUS OUTPUT CURRENT
DC (A):
MAX OUTPUT CURRENT
DC (A):
DC VOLTAGE WORKING RANGE
10-18 DC (V):
BADCD
12
-10
10
20
10 - 18
BADCD
24
-10
10
20
20 - 55