background image

R40-17...L120-11

Model: E25

en

Assembly and Operating Instructions

Tubular drives with crank handle activation for roller

shutters

Important information for:

• Fitters / • Electricians / • Users

Please forward accordingly!

These instructions must be kept safe for future reference.

Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
www.becker-antriebe.com

2010 301 230 0b     17/11/2020   

Summary of Contents for E25

Page 1: ...andle activation for roller shutters Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com 2010 301 230 0b 17 11 2020 ...

Page 2: ...the drive adapter with screw connection 9 Mounting the drive in the tube 9 Adjusting the limit positions with a rotary switch or a locking button 11 Deleting the limit positions with a rotary switch or a locking button 11 Setting the limit positions using the programming unit 12 Deleting the limit positions using the programming unit 13 Additional function offset lower limit position 14 Using the ...

Page 3: ... of pictograms CAUTION CAUTION indicates a hazardous situation which if not avoided could result in injury ATTENTION ATTENTION indicates measures that must be taken to avoid damage to property Denotes user tips and other useful information Warranty Structural modifications and incorrect installation which are not in accordance with these and our other instructions can result in serious injuries e ...

Page 4: ...f safety instructions is not exhaustive since it would be impossible for the standard to include all sources of danger For example the design of the operated product the way the drive works in the situation it is installed in or even the way the end product is mounted in the end user s place of use cannot be taken into consideration by the drive manufacturer If any questions or uncertainties regar...

Page 5: ...e g the power supply unit are live Physical injuries or damage to property can result in the event of unauthorised interventions or failure to heed warnings Be careful when touching the tubular drive as it heats up during operation for technical reasons Before installation shut down all lines and control devices that are not essential for op eration Crushing or shearing points must be avoided or p...

Page 6: ...d in order to protect the safety of the users and others since these ac tions can impair the system s safety and carry the risk of personal injury and property damage The drive manufacturer does not accept liability for damages or injury arising from such actions Always observe the information in these instructions when operating or repairing the system The drive manufacturer does not ac cept liab...

Page 7: ...ly the power supply to the connecting cable must be disconnected Insert a suitable flathead screwdriver right into the recess of the locating latch so that the latch releases the locating lug from the plug Now you can pull out the connecting cable along with the flathead screwdriver A A locating latch 7 en ...

Page 8: ...ve head 1 and wall bracket 2 The clear dimension of the box X minus the space required at the side M and idler G gives the length L of the barrel L X M G The space required at the side M varies depending on the combination of drive and wall bracket Then mount the wall bracket and idler Ensure that the barrel is aligned at right angles to the wall and that sufficient axial play is al lowed for the ...

Page 9: ... by rotating the drive adapter into a different groove recess These groove recesses have different sizes and allow the drive to fit exactly Y X For round shafts Measure the lug of the thrust ring X Y Then notch the tube on the motor side so the lug of the thrust ring can also be pushed into the shaft There must be no play between the lug of the thrust ring and the shaft 10 mm To ensure secure torq...

Page 10: ...imit positions is possible where a stop system is present on both sides using the rotary switch set Item no 4901 001 158 0 a standard rotary switch or the programming unit for drives with electronic limit switching Item no 4935 200 011 0 Connect the wires of the tubular drive to those of the same colour in the program ming operator control and switch on the power supply Check the direction of trav...

Page 11: ...pper limit position has been set The dis tance from the upper stop is automatically cyclically checked and if necessary corrected Move 3x in succession to the permanent upper stop from a distance of 300 mm without interruption The tubular drive confirms after the limit position has been approached three times The limit position is then shifted approx 10 mm before stopping Move 3x in succession to ...

Page 12: ... drive switches off prematurely while opening or closing due to an obstruc tion the obstruction can be cleared by reversing a short way and removing the obstruc tion The desired limit position can then be set by opening closing again A reduced torque in the direction of travel only occurs after the upper limit position has been set The dis tance from the upper stop is automatically cyclically chec...

Page 13: ...s of the deletion sequence Deleting a limit position when 2 limit positions are programmed black brown blue green yellow black brown blue green yellow Programming button Travel button Open close to the limit position to be deleted Press the programming button and keep it pressed Then press down the travel button and keep it pressed Now release the programming button but continue to keep the travel...

Page 14: ...al and electrical accessories made by the drive manufacturer which have been tested and which are suitable for use with these drives For 7 mm hexagonal tube and 8 mm square tube The crank handle is to be used only in the event of a power failure It must be ensured that the limit positions are not overrun After using the crank handle the limit posi tions must be referenced again To do this move in ...

Page 15: ...ng direction to the control buttons UP and DOWN EXTEND and RETRACT If the drive is to be operated with devices which contain sources of interference the elec trician must ensure suitable interference suppression for the relevant devices Torque detection A correctly installed tubular drive reacts to extraordinarily large increases in load during operation between the limit positions and thereby pre...

Page 16: ...it positions Stops have broken off or one or several attachments are broken Repair system reset tubular drive then re program limit positions Tubular drive stops arbitrarily cannot be restarted in the same direction Use a more powerful tubular drive Ensure that the system runs smoothly Delete and reset the limit positions Tubular drive does not run in the right direction Tubular drive is overheate...

Page 17: ... assignment of the black and brown wires according to the direction of travel is de pendent on how the drive is installed mounted to the right or to the left Control via one button Electronic black brown blue green yellow 17 en ...

Page 18: ...Declaration of conformity 18 en ...

Page 19: ...19 ...

Page 20: ......