5.3.1 Basic S-Registers "ATSn=x"
Table 5-11 Basic S-Registers "ATSn=x"
COMMAND
FUNCTION AND DESCRIPTION
+REF.
S0=
Sets the number of rings on which the modem answers. 0 value
disables auto-answer.
+000
S1=
Counts and stores number of rings from an incoming call.
+000
S2=
Defines escape code character, default '+' (43 dec.). A value of 128
to 255 disables the escape code.
+043
S3=
Defines ASCII Carriage Return.
+013
S4=
Defines ASCII Line Feed.
+010
S5=
Defines ASCII Backspace. A value of 128 to 255 disables the
Backspace key's delete function.
+008
S6=
Sets the number of seconds the modem waits before dialing if 'X0' or
'X1' is selected. If a setting of 'X2,' 'X7' is selected, the modem dials
as soon as it detects a dial tone. This register also sets the time-out
interval for the "W" dial modifier to wait for the dial tone. (See also
S41b4.)
+003
S7=
Sets duration, in number of seconds modem waits for a carrier.
+060
S8=
Sets duration, in seconds, for pause (,) option in Dial command and
pause between command re-executions for Repeat (>) command.
+002
S9=
Sets duration, in tenths of a second of remote carrier signal before
recognition. (Ignored if in non-FSK or half-duplex operation.)
+006