2.1.2 Start program
Q
As soon as a program is started
using the green
Start
button, the
program sequence is displayed once
as a graph and as a list of
parameters. The currently active
parameter is highlighted in a darker
shade of grey in the program slider,
while parameters that have already
been processed recede into the
background (image 10.2). In the
graph, the active parameter is also
highlighted in a darker shade of grey.
In this way, the program status can
be seen at a glance, even from a
greater distance from the device.
The parameter slider provides more
detailed information. As already
described, the active parameter
is highlighted in a darker shade of
grey. If a subsequent parameter is
controlled, the parameter bar scrolls
accordingly. Subsequent parameters
can be checked by dragging the
process bar to the appropriate
positions with a "swiping motion".
Q
The vacuum status is displayed in %.
Display, Status: A running firing program
Abort
Edit program
Soak temp.
450°C
Closing time
03:00mm:ss
Pre dry time
03:00mm:ss
Correction
DC 9.2
Correction
Start
Select program
Display, Status: Select program / select a folder / select a program / Preview
Professional
Temper
Start temp.
450 °C
Heat rate
35 °C/min
Pre dry
Yes
Final temp.
720 °C
Pre dry time
03:00 mm:ss
Hold time
01:00 mm:ss
Closing time
03:00 mm:ss
Soak temp.
450 °C
Temper temp.
690 °C
No
Opening temp.
720 °C
Opening time
02:00 mm:ss
Vacuum
Yes
Release vacuum
Heat up
Vacuum end
720 °C
Soak time
01:00 mm:ss
Temper time
02:00 mm:ss
Preview
Image 10.1
Image 10.2