11
500°C
DC 9.2
500°C
Dentin 1
2.1.4 Program abort
Q
If you want to end a program
prematurely or cancel it, you can
do this by pressing the red
Abort
function field. In this case, the
program abort must be confirmed
again by a security prompt (image
11.2).
OK
Abort
Display, Status: Select program / select a folder / select a program / Start / Edit program
Display, Status: Program abort, abort confirmation
Yes
No
Temper
Start temp.
450 °C
Heat rate
35 °C/min
Pre dry
Yes
Final temp.
820 °C
Pre dry time
03:00 mm:ss
Hold time
01:00 mm:ss
Closing time
03:00 mm:ss
Soak temp..
450 °C
Temper temp.
690 °C
Professional
720°C
Opening temp.
720 °C
Opening time
02:00 mm:ss
Vacuum
Yes
Release vacuum
Heat up
Vacuum end
720 °C
Soak time
01:00 mm:ss
Temper time
02:00 mm:ss
DC 9.2
Correction
Should the program really
be aborted?
Abort
2.1.3 Change program during a
program run
Q
Parameters can be changed during
a program run via the program
Edit program
button. As with the
program preview (image 10.2), these
changes only apply to the current
brand. After the end of the process,
the initial values are valid again.
Q
Only values that the oven has not yet
started or completed can be changed.
Values that you can no longer change
are optically pushed back into the
back-ground. Press the green
OK
function field to activate changes and
Continue
, you get back to the para-
meter slider and the graph.
Q
Press programs cannot be changed
while the program is running.
Edit program
No
Image 11.1
Image 11.2
Delete