Chapter 7 Service Configuration
Command
Function
zte(cfg)#
set ethernet-oam port
<
portlist
>
period
<
1-10
>
timeout
<
2-20
>
mode
{
active
|
passive
}
This configures OAM
discovery period,
timeout range and
mode on port.
The parameter
period
<
1-10
>: discovery period, 1 represents
10ms. 2 represents 20ms and so on. By default, 10 represents
100ms.
The parameter
timeout
<
2-20
>: timeout, by default it is 5
seconds
The parameter
mode
[
active
|
passive
]: discovery mode, it
is active by default.
4. To start or stop OAM remote-loopback function on port, use
the following command.
Command
Function
zte(cfg)#
set ethernet-oam
remote-loopback port
<
portlist
>{
start
|
stop
}
This starts or stops
OAM remote-loopback
function on port.
The prerequisites of enabling this function is that the global
OAM function has been enabled, the OAM function has been
enabled on destination port, and the OAM discovery process
has been completed.
5. To set remote-loopback timeout value on port, use the follow-
ing command.
Command
Function
zte(cfg)#
set ethernet-oam
remote-loopback timeout
<
1-10
>
This sets remote-
loopback timeout
value on port.
The parameter
timeout
: the default is 3s.
6. To enable or disable link monitor function, use the following
command.
Command
Function
zte(cfg)#
set ethernet-oam port
<
portlist
>
link-monitor
{
enable
|
disable
}
This enables or
disables link monitor
function.
7. To configure the symbol period event which is used for link
monitor, use the following command.
Confidential and Proprietary Information of ZTE CORPORATION
187