16
List of warnings and errors
No.
Name
Warning
1
Error
1
Description
1 SAFE
*
X
Input SAFE activated
(external error, irrelevant in DMS2 ED)
2 Control signal
X
Value of control signal ≤ 3 mA
(it applies to ranges 4 – 20 / 20 – 4 mA)
4 Torque
X
Induced torque beyond end-limit positions or disconnected torque sensor
6 Heat protection
X
Input heat protection activated
7 Sense of rotation
X
Reverse sense of rotation
(for CONTROL only)
8 EEPROM
X
Wrong control sum of parameters in EEPROM
9 RAM
X
Wrong control sum of parameters in RAM
10 Parameters
X
Wrong parameters in EEPROM
11 Setting modes
X
Setting mode from push-buttons or PC
12 Torque sensor
X
Disconnected or defective torque sensor
13 Sensor 1
X
Error of sensor of position 1
(lowest stage)
14 Sensor 2
X
Error of sensor of position 2
15 Sensor 3
X
Error of sensor of position 3
16 Sensor 4
X
Error of sensor of position 4
(highest stage)
17 Calibration
X
Autocalibration not carried out
18 Torque setting
X
Wrong setting of torques
(parameters Torque O/Z/50/100%)
19 Stroke
X
Wrong setting of stroke
(parameters Position O/Z)
20 Rotation error
X
The actuator does not rotate
21 High temperature
X
Permitted max. temperature exceeded
(parameter Temperature max.)
22 Low temperature
X
Permitted max. temperature exceeded
(parameter Temperature min.)
23 LCD internal *
X
Display of LCD internal does not communicate or not added
in parameter CAN of configuration
24 LCD external *
X
Display of LCD external does not communicate or not added
in parameter CAN of configuration
25 Fieldbus *
X
Module of industrial bus does not communicate or not added in
parameter CAN of configuration
26 CAN *
X
Error of bus CAN
(short circuit, interruption, only sensor communicates)
27 Fieldbus activity*
X
Connection to industrial bus not active
28 Phase *
X
Inverse order of phases or some phase missing
29 Relay of service
X
Service life of relay MO/MZ at CONTROL exceeded
life
(parameter Relay of service life)
30 Reset
X
Non-standard Reset of unit induced
(watchdog etc.)
31 ROM
X
Wrong control sum of program in ROM
32 CAN version *
X
Sensor, LCD display or module Fieldbus have incompatible versions
of firmware
33 Wrong command *
X
Commands Open and Close entered at the same time
34 Wrong inertia
–
–
Wrong inertia measured by autocalibration
(for autocalibration only)
35 Wrong run-down
–
–
Wrong run-down measured by autocalibration
(for autocalibration only)
41 Wrong position
X
Servo-drive is in position 25 % behind working stroke
1
)
Assignment can vary depending on the version of firmware of the sensor control unit.
* Applies to DMS2 only.
Memory of number of induced errors
– For all ascertained warnings and errors, DMS2 uses counters of occurrence of these warnings and errors during
operation of the system.
– Values of the counters are stored to the EEPROM memory and are preserved even in case of the power supply fall-out.
– Reading of the counters is possible by means of the program for PC
– Clearing of the counters is possible by means of the program for PC with the level of authorization
“SERVICE”.