background image

3

General Information

:DUUDQW\862QO\

(a) ZOLL Medical Corporation warrants to the original 
equipment purchaser that beginning on the date of 
installation, or thirty (30) days after the date of shipment 
from ZOLL Medical Corporation's facility, whichever first 
occurs, the equipment (other than accessories and 
electrodes) will be free from defects in material and 
workmanship under normal use and service for the 
period of one (1) year. During such period ZOLL Medical 
Corporation will, at no charge to the customer, either 
repair or replace (at ZOLL Medical Corporation's sole 
option) any part of the equipment found by ZOLL Medical 
Corporation to be defective in material or workmanship. 
If ZOLL Medical Corporation's inspection detects no 
defects in material or workmanship, ZOLL Medical 
Corporation's regular service charges shall apply. (b) 
ZOLL Medical Corporation shall not be responsible for 
any equipment defect, the failure of the equipment to 
perform any function, or any other nonconformance of 
the equipment, caused by or attributable to: (i) any 
modification of the equipment by the customer, unless 
such modification is made with the prior written approval 
of ZOLL Medical Corporation; (ii) the use of the 
equipment with any associated or complementary 
equipment, (iii) installation or wiring of the equipment 
other than in accordance with ZOLL Medical 
Corporation's instructions. (c) This warranty does not 
cover items subject to normal wear and burnout during 
use, including but not limited to lamps, fuses, batteries, 
patient cables and accessories. (d) The foregoing 
warranty constitutes the exclusive remedy of the 
customer and the exclusive liability of ZOLL Medical 
Corporation for any breach of any warranty related to the 
equipment supplied hereunder. (e) Limitation of Liability: 
ZOLL shall not in any event be liable to Purchaser, nor 
shall Purchaser recover, for special, incidental or 
consequential damages resulting from any breach of 
warranty, failure of essential purpose, or under any other 
legal theory including but not limited to lost profits, lost 
savings, downtime, goodwill, damage to or replacement 
of equipment and property, even if ZOLL has been 
advised of the possibility of such damages. 
THE WARRANTY SET FORTH HEREIN IS EXCLUSIVE 
AND ZOLL MEDICAL CORPORATION EXPRESSLY 
DISCLAIMS ALL OTHER WARRANTIES WHETHER 
WRITTEN, ORAL, IMPLIED, OR STATUTORY, 
INCLUDING BUT NOT LIMITED TO ANY 
WARRANTIES OF MERCHANTABILITY OR FITNESS 
FOR A PARTICULAR PURPOSE. 
For additional information, please call ZOLL Medical 
Corporation at 1-800-348-9011(in Massachusetts: 
1-978-421-9655). International customers should call the 

nearest authorized ZOLL Medical Corporation service 
center.

 

8VHRI1RQ6WDQGDUG$FFHVVRULHVZLWK

=2//(TXLSPHQW

Safety and effectiveness data submitted to the Food and 
Drug Administration (FDA) by ZOLL Medical Corporation 
to obtain approval to market is based upon the use of 
ZOLL accessories such as disposable electrodes, 
patient cables and batteries. 

Summary of Contents for Base Powercharger 4x4

Page 1: ...ZOLL Base PowerCharger4x4 Operator s Manual Base PowerCharger 4x4 TM CAUTIO N DO NOT BLOCK VENTS OR PLACE ANYTHING ON TOP OF THE VENTS HEAT DAMAGE MAY OCCUR Part Number 9650 0054 Rev G...

Page 2: ...North America Consult your purchasing agreement for terms and conditions associated with your warranty Outside of North America consult the ZOLL authorized representative In order to maintain this wa...

Page 3: ...UH DWWHU RPSDUWPHQW 7HVWLQJ 3URFHGXUH DXOW RGHV DQG HILQLWLRQV 4XLFN 5HIHUHQFH KDUW IRU 2 DVH 3RZHU KDUJHU 4x4 ZLWK 4XLFN KDUJH 6HFWLRQ 2SHUDWLRQ XWR7HVW 2SHUDWLQJ RQWUROV DQG QGLFDWRUV 6HWXS DWWHU KD...

Page 4: ...ZOLL Base PowerCharger 4x4 Operator s Manual ii This page intentionally left blank...

Page 5: ...er 4x4 with AutoTest automatically tests battery capacity with each battery recharge In addition the ZOLL Base PowerCharger 4x4 with AutoTest illuminates the Batt Ready indicator when the battery is f...

Page 6: ...HVKRRWLQJ This section describes several routine checks to assure proper unit operation It includes cleaning and maintenance instructions and troubleshooting guides intended for use by non technical p...

Page 7: ...This warranty does not cover items subject to normal wear and burnout during use including but not limited to lamps fuses batteries patient cables and accessories d The foregoing warranty constitutes...

Page 8: ...epeated use of partially charged batteries will reduce their capacity and operating life Do not use a battery unless the BATT READY indicator is lit and the FAULT light is off Failure to do so may res...

Page 9: ...compartment FAULT Illuminates when battery capacity test or battery compartment test fails Separate indicator light for each battery compartment TESTING Illuminates when either a battery test or a bat...

Page 10: ...order to allow tracking of loan equipment You will be given a Return Claim Number under which to return the ZOLL Base PowerCharger 4x4 Send the unit in its original packaging to ZOLL Medical Corporati...

Page 11: ...x4 refer to QuickCharge unless otherwise specified If your device does not indicate QuickCharge or AutoTest on the label in the upper right corner refer to the QuickCharge section of this manual for p...

Page 12: ...1 Illuminates when either a battery capacity test cycle is in progress or a battery compartment test is completed Illuminates with the BATT READY light indicating a usable fully charged battery capab...

Page 13: ...nsecutive beeps to indicate that the battery is not fully charged and should not be used In addition all four indicator lights will illuminate for four 4 seconds and then go off Repeated use of partia...

Page 14: ...tor lights will illuminate for four 4 seconds and then go off DWWHU RPSDUWPHQW 7HVWLQJ 3URFHGXUH The ZOLL Base PowerCharger 4x4 has four battery compartments that are able to test and charge batteries...

Page 15: ...d range Low Constant Current Amount of current during a charge was below the specified range High Constant Current Amount of current during a charge was above the specified range VCC Voltage Internal...

Page 16: ...e ZOLL Base PowerCharger 4x4 will beep to indicate the battery has been removed and should NOT be used The POWER light should be on as long as the unit is plugged into a live AC source 23 5 7 21 4XLFN...

Page 17: ...r 4x4 refer to AutoTest unless otherwise specified If your device does not indicate QuickCharge or AutoTest on the label in the upper right corner refer to the QuickCharge section of this manual for p...

Page 18: ...tment or any other failure occurs There are four FAULT indicator lights Each one corresponds to the battery charging testing compartment directly above 7 67 1 Illuminates when either a battery capacit...

Page 19: ...cific defect see Fault Codes and Definitions on page 17 and take corrective action Before disposing of the battery test the battery compartment for defective operation see Battery Compartment Testing...

Page 20: ...ry will cause an audible warning of five 5 consecutive beeps to indicate that the battery is not fully charged and should not be used All four indicator lights will illuminate for four 4 seconds and t...

Page 21: ...range Low Constant Current Amount of current during a charge was below the specified range High Constant Current Amount of current during a charge was above the specified range VCC Voltage Internal fi...

Page 22: ...ger 4x4 will beep to indicate the battery has been removed and should NOT be used The POWER light should be on as long as the unit is plugged into a live AC source 23 5 7 21 XWR7HVW 5 5 21 77 5 8 7 7...

Page 23: ...all battery compartments empty check that all indicator lights except POWER are off 3 Press the TEST button under each compartment to verify that the compartments are fully operational see Battery Com...

Page 24: ...r power source Check for blown fuse 2 CHARGER ON indicator light does not illuminate when battery is in compartment Check that battery is properly seated in compartment Check that battery contacts are...

Page 25: ...ent refer to the ZOLL Battery Management Program part number 9650 0019 2 DWWHU 3DFNV ZOLL PD 4410 Smart Smart Ready Battery and XL Battery Packs are five cell assemblies of sealed lead acid batteries...

Page 26: ...ZOLL Base PowerCharger 4x4 Operator s Manual 22 This page intentionally left blank...

Page 27: ......

Page 28: ...336 ZOLL Medical France 189 Rue Nationale 10 78310 Coignieres FRANCE Telephone 33 1 30 05 14 95 Telefax 33 1 30 49 06 93 Middle East Africa Regional Office 14 Persefonis Ekali 14578 Athens Greece Tele...