background image

ZOLL Base PowerCharger 

4x4

 Operator’s Manual

4

:DUQLQJVDQG&DXWLRQV

:DUQLQJV

*HQHUDO

The ZOLL Base PowerCharger

4x4

 is protected 

against interference from radio frequency 
emissions typical of two-way radios used in 
emergency service/public safety activities. Users 
of the ZOLL Base PowerCharger

4x4

 should 

assess the devices’ performance in their 
environment of use for the possibility of radio 
frequency interference from high-power sources.

 

Use only the AC power line cord supplied with the 
device. Failure to use the proper line cord could 
result in excess leakage currents and reduced 
safety.

Do not disassemble the ZOLL Base 
PowerCharger

4x4

. A shock hazard exists. Refer 

all problems to ZOLL Technical Service.

Follow all recommended maintenance 
instructions. If a problem occurs, obtain service 
immediately. Do not use the ZOLL Base 
PowerCharger

4x4

 until the unit has been 

inspected by the appropriate personnel.

Do not place anything on top of or beneath the 
ZOLL Base PowerCharger

4x4

, such as blankets 

or cloths. Doing so may block the vents on the 
unit, preventing proper dissipation of heat during 
operation.

Do not sterilize the ZOLL Base PowerCharger

4x4

.

Do not use alcohol or ketones (MEK, acetone, 
etc.) on the ZOLL Base PowerCharger

4x4

.

Always wait until the ZOLL Base 
PowerCharger

4x4

 has completed its charge cycle 

before removing batteries.

Repeated use of partially charged batteries will 
reduce their capacity and operating life.

Do not use a battery unless the 

BATT. READY 

indicator is lit and the 

FAULT

 light is off. Failure to 

do so may result in the use of a fully depleted 
battery.

Only charge XL Battery packs in a ZOLL Base 
PowerCharger

4x4

 marked “XL Battery Ready”. 

Failure to do so will reduce battery capacity and 
operating life.

Do not install batteries into Monitor/Defibrillators 
when storage may exceed 90 days. Battery 
damage may occur.

Operator Safety

Do not operate the ZOLL Base PowerCharger

4x4

 

in the presence of flammable agents (such as 
gasoline), oxygen-rich atmospheres, nitrous 
oxide, or flammable anesthetics. Using the device 
near the site of a gasoline spill may cause an 
explosion. 

Do not immerse or set the ZOLL Base 
PowerCharger

4x4

 in fluid. Using the device near 

or within puddles of water may present a shock 
hazard to the operator, patient, and nearby 
personnel.

Patient Safety

Do not mount the device directly above the 
patient. Locate the ZOLL Base PowerCharger

4x4

 

and ZOLL resuscitation devices where they 
cannot harm the patient if they fall.

Caution

Federal (U.S.A.) law restricts this device to sale 
by or on the order of a physician.

When a fully charged battery is placed into the 
ZOLL Base PowerCharger

4x4

 with the AutoTest, 

the AutoTest will 

NOT

 activate and the 

BATT. 

READY

 indicator will illuminate within a few 

minutes after inserting the battery into the 
charger. Therefore, it is possible to have a shorter 
battery run time than expected from the AutoTest.

Summary of Contents for Base Powercharger 4x4

Page 1: ...ZOLL Base PowerCharger4x4 Operator s Manual Base PowerCharger 4x4 TM CAUTIO N DO NOT BLOCK VENTS OR PLACE ANYTHING ON TOP OF THE VENTS HEAT DAMAGE MAY OCCUR Part Number 9650 0054 Rev G...

Page 2: ...North America Consult your purchasing agreement for terms and conditions associated with your warranty Outside of North America consult the ZOLL authorized representative In order to maintain this wa...

Page 3: ...UH DWWHU RPSDUWPHQW 7HVWLQJ 3URFHGXUH DXOW RGHV DQG HILQLWLRQV 4XLFN 5HIHUHQFH KDUW IRU 2 DVH 3RZHU KDUJHU 4x4 ZLWK 4XLFN KDUJH 6HFWLRQ 2SHUDWLRQ XWR7HVW 2SHUDWLQJ RQWUROV DQG QGLFDWRUV 6HWXS DWWHU KD...

Page 4: ...ZOLL Base PowerCharger 4x4 Operator s Manual ii This page intentionally left blank...

Page 5: ...er 4x4 with AutoTest automatically tests battery capacity with each battery recharge In addition the ZOLL Base PowerCharger 4x4 with AutoTest illuminates the Batt Ready indicator when the battery is f...

Page 6: ...HVKRRWLQJ This section describes several routine checks to assure proper unit operation It includes cleaning and maintenance instructions and troubleshooting guides intended for use by non technical p...

Page 7: ...This warranty does not cover items subject to normal wear and burnout during use including but not limited to lamps fuses batteries patient cables and accessories d The foregoing warranty constitutes...

Page 8: ...epeated use of partially charged batteries will reduce their capacity and operating life Do not use a battery unless the BATT READY indicator is lit and the FAULT light is off Failure to do so may res...

Page 9: ...compartment FAULT Illuminates when battery capacity test or battery compartment test fails Separate indicator light for each battery compartment TESTING Illuminates when either a battery test or a bat...

Page 10: ...order to allow tracking of loan equipment You will be given a Return Claim Number under which to return the ZOLL Base PowerCharger 4x4 Send the unit in its original packaging to ZOLL Medical Corporati...

Page 11: ...x4 refer to QuickCharge unless otherwise specified If your device does not indicate QuickCharge or AutoTest on the label in the upper right corner refer to the QuickCharge section of this manual for p...

Page 12: ...1 Illuminates when either a battery capacity test cycle is in progress or a battery compartment test is completed Illuminates with the BATT READY light indicating a usable fully charged battery capab...

Page 13: ...nsecutive beeps to indicate that the battery is not fully charged and should not be used In addition all four indicator lights will illuminate for four 4 seconds and then go off Repeated use of partia...

Page 14: ...tor lights will illuminate for four 4 seconds and then go off DWWHU RPSDUWPHQW 7HVWLQJ 3URFHGXUH The ZOLL Base PowerCharger 4x4 has four battery compartments that are able to test and charge batteries...

Page 15: ...d range Low Constant Current Amount of current during a charge was below the specified range High Constant Current Amount of current during a charge was above the specified range VCC Voltage Internal...

Page 16: ...e ZOLL Base PowerCharger 4x4 will beep to indicate the battery has been removed and should NOT be used The POWER light should be on as long as the unit is plugged into a live AC source 23 5 7 21 4XLFN...

Page 17: ...r 4x4 refer to AutoTest unless otherwise specified If your device does not indicate QuickCharge or AutoTest on the label in the upper right corner refer to the QuickCharge section of this manual for p...

Page 18: ...tment or any other failure occurs There are four FAULT indicator lights Each one corresponds to the battery charging testing compartment directly above 7 67 1 Illuminates when either a battery capacit...

Page 19: ...cific defect see Fault Codes and Definitions on page 17 and take corrective action Before disposing of the battery test the battery compartment for defective operation see Battery Compartment Testing...

Page 20: ...ry will cause an audible warning of five 5 consecutive beeps to indicate that the battery is not fully charged and should not be used All four indicator lights will illuminate for four 4 seconds and t...

Page 21: ...range Low Constant Current Amount of current during a charge was below the specified range High Constant Current Amount of current during a charge was above the specified range VCC Voltage Internal fi...

Page 22: ...ger 4x4 will beep to indicate the battery has been removed and should NOT be used The POWER light should be on as long as the unit is plugged into a live AC source 23 5 7 21 XWR7HVW 5 5 21 77 5 8 7 7...

Page 23: ...all battery compartments empty check that all indicator lights except POWER are off 3 Press the TEST button under each compartment to verify that the compartments are fully operational see Battery Com...

Page 24: ...r power source Check for blown fuse 2 CHARGER ON indicator light does not illuminate when battery is in compartment Check that battery is properly seated in compartment Check that battery contacts are...

Page 25: ...ent refer to the ZOLL Battery Management Program part number 9650 0019 2 DWWHU 3DFNV ZOLL PD 4410 Smart Smart Ready Battery and XL Battery Packs are five cell assemblies of sealed lead acid batteries...

Page 26: ...ZOLL Base PowerCharger 4x4 Operator s Manual 22 This page intentionally left blank...

Page 27: ......

Page 28: ...336 ZOLL Medical France 189 Rue Nationale 10 78310 Coignieres FRANCE Telephone 33 1 30 05 14 95 Telefax 33 1 30 49 06 93 Middle East Africa Regional Office 14 Persefonis Ekali 14578 Athens Greece Tele...

Reviews: