No.
Parameter
Set arrange
Unit in Edit
Initial set
U01
Presser
Presser
Presser
Presser up to
up to
up to
up to maximum position
maximum position
maximum position
maximum position
Height of maximum position of pedal operation is
set.
0~17.0
0.1mm
14.0mm
U02
Presser up to intermediate position
Height of intermediate position of pedal operation
is set
.
0~14.0
0.1mm
6.0mm
U03
Presser lifter cloth setting position
Height of cloth setting position
of pedal operation
is set
.
0~14.0
0.1mm
0
U04
Pedal to down position of 2-pedal (%)
Operation feeling at the time of
2-pedal is set
.
5~95
1%
80%
U05
Lifting position of presser foot of 2-pedal
Operation feeling at the time of 2-pedal is set
5~95
1%
50%
U06
Set Needle thread tension at sewing end
0~200
1
35
U07
Needle thread tension at thread trimming
0~200
1
35
U08
Set Needle thread tension of basting for
sewing together
0~200
1
60
U09
Soft-start speed setting 1st stitch
400~4200
100rpm
800rpm
U10
Soft-start speed setting 2nd stitch
400~4200
100rpm
800rpm
33