background image

QWIK JON

®

 PREMIER 201 SYSTEM

INSTALLATION INSTRUCTIONS

PREINSTALLATION CHECKLIST

NOTICE TO INSTALLER:  Instructions must remain with installation.

© Copyright 2020 Zoeller Co. All rights reserved.

DATE INSTALLED:

MODEL NUMBER:

REFER TO WARRANTY ON PAGE 2.

SEE BELOW FOR LIST OF WARNINGS

60 Hz

Product information presented 
of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

- 1  -

FM3282

1020

NEW

Supersedes

P/N 084963

1. To reduce the risk of electrical shock, a properly grounded receptacle or

control box must be installed in accordance with the governing codes. Never

remove ground pin from plug.

2. Make certain that the ground fault interrupter protected receptacle or control

box is within the reach 

 

of the pump’s power supply cord. DO NOT USE AN

EXTENSION CORD. Extension cords that are too long or too light do not

deliver 

 voltage to the pump motor, and they could present a safety

hazard if the insulation were to become damaged or the connection end were

to fall into a damp or wet area.

3. Make sure the pump's electrical supply circuit is equipped with fuses or circuit

breakers of proper capacity. 

 

A separate branch circuit is recommended, sized

according to the governing electrical codes for the current shown on the pump

name plate.

4. Testing for ground.   As a safety measure, each electrical outlet should be

checked for ground using an Underwriters Laboratory Listed circuit analyzer

which will indicate if the power, neutral and ground wires are correctly connected

to your outlet.  

If they are not, call a 

 licensed electrician.

5. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS

POWER SOURCE BEFORE HANDLING. 

 

If pump is wired direct, de-energize

the circuit at the control box. 

 

DO NOT, UNDER ANY CIRCUMSTANCES,

REMOVE THE GROUND PIN. 

 

Wear insulated protective shoes and do not

stand in water. 

 

Certain plug types may include a 3-prong ground plug to help

protect against electrical shock. 

 

A properly grounded 3-prong receptacle or

control box must be installed in accordance with governing codes.

6. Installation and servicing of the pump's electrical circuits and hardware should

only be performed by a 

 licensed electrician.

7. Installation and maintenance of this appliance is not intended for persons

(including children) with reduced physical, sensory or mental capabilities, or

lack of experience or knowledge, unless they have been given supervision or

instruction concerning use of the appliance by a person responsible for their

safety.

8. Risk of electrical shock. 

 

Do not remove power supply cord and strain relief

or connect conduit directly to the pump.  If the supply cable is damaged, it

must be replaced by an authorized Zoeller Representative.

9. Pump contains oil which becomes pressurized and hot when operating. Allow

2-1/2 hours after disconnecting before attempting service.

p

m

u

P

.

0

 is not intended for potable water due to possible contamination by oil

contained in the pump.

 11.  Risk of electrical shock.

 

 

These  pumps  have  not  been

  investigated

  for use

in swimming pools and marine areas.

1. Inspect all materials. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using. DO NOT remove the

test plugs from the pump.

2. Carefully read all the literature provided to familiarize yourself with 

 details regarding installation and use. These materials should be retained for

future reference.

SAFETY INSTRUCTIONS

TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR 

PROPERTY  DAMAGE,  READ  AND  FOLLOW  ALL  SAFETY 

INSTRUCTIONS IN THIS MANUAL AND ON THE PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION AND 

OPERATION OF THIS UNIT AND MUST BE KEPT WITH THE PUMP.

THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS PRIOR 

TO PERFORMING ANY WORK ON THIS PUMP.

MAINTAIN ALL SAFETY DECALS.

This is a 

SAFETY ALERT SYMBOL. 

Symbol on the pump or in the manual, look for one of the 
following  signal  words  and  be  alert  to  the  potential  for 
personal injury or property damage.

Warns of hazards that 

CAN 

cause serious personal injury, 

death or major property damage.

Warns  of  hazards  that 

CAN 

cause  personal  injury  or 

property damage.

CAUTION

Warns of electrical shock hazards that can cause serious 
personal injury, death or major property damage.

Read operator's manual.

Identifies any terminal which is intended for connection to
an external conductor for protection against electrical 
shock in case of a fault, or the terminal of a protective 
earth (ground) electrode.

www.zoellerpumps.com

®

Register your 

Zoeller Pump Company 

Product on our website:

http://reg.zoellerpumps.com/

Summary of Contents for QWIK JON PREMIER 201

Page 1: ...of this appliance is not intended for persons including children with reduced physical sensory or mental capabilities or lack of experience or knowledge unless they have been given supervision or ins...

Page 2: ...IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY Some jurisdictions do not allow limitations on the duration of an...

Page 3: ...with all applicable governing codes Option hose with clamp Item Description 1 Qwik Jon Preimer Sewage Removal System 201 0006 2 Outlet Pipe Assembly Repair Kit 084993 3 Tank Cover Repair Kit 084994 4...

Page 4: ...aterial to pump intake Hold flush handle down on toilet for 15 seconds If unit will not clear unplug and wait for 30 minutes Plug unit back in and repeat If unit still will not turn off it will need t...

Page 5: ...the pump Vent Access to a vent pipe is required in some markets The use of a mechanical vent system is NOT recommended as the toilet will not NOTE If a built in installation is to be used locate the p...

Page 6: ...the bottom and sides of the toilet tank to ensure against interference from pipe runs later 4 Remove the toilet from the pump unit and set it aside STAND ALONE INSTALLATION BEHIND THE WALL INSTALLATI...

Page 7: ...rge previously marked 6 For markets requiring a pipe vent clean and solvent weld the vent piping as required for proper venting Cut and the pipe and as required for 1 DN25 diameter discharge pipe may...

Page 8: ...pipe to the top of the Qwik Jon Premier Copyright 2020 Zoeller Co All rights reserved 8 Connect the desired inlet pipe from other xtures to the side inlet s of the Qwik Jon Premier Use a 1 3 4 44 mm h...

Page 9: ...POWER STEP 5 Connect all inlet piping to the Qwik Jon Premier if desired Plug the power cord into a wall socket to provide power to the unit Copyright 2020 Zoeller Co All rights reserved 9...

Page 10: ...d 10 1 1 2 stack vent Remove the stack vent pipe and discharge pipe from the top of the Qwik Jon Premier Mechanical and Electrical Hazard Disconnectpowerprior to maintenance or opening Thisequipmentis...

Page 11: ...Copyright 2020 Zoeller Co All rights reserved 11 Take o the lid of the Qwik Jon Premier Li the switch housing and pump out of the tank...

Page 12: ...0 Zoeller Co All rights reserved 12 The oat sleeve can be removed from the switch housing to clear the oat of debris The discharge elbow pipe can be disconnected from the volute of the pump to be clea...

Page 13: ...5 pipe max 368 112 m 3 4 DN20 pipe max 253 77 m 1 DN25 pipe max 483 147 m 3 4 DN20 pipe max 333 101 m 1 DN25 pipe max 597 182 m 3 4 DN20 pipe max 413 126 m 1 DN25 pipe max 769 234 m 3 4 DN20 pipe max...

Page 14: ...isolantes et ne pas se tenir dans l eau Certains types de prises peuvent comporter une fiche trois broches avec mise la terre pour aider prot ger contre les d charges lectriques Une prise de courant o...

Page 15: ...stall utilis ou entretenu conform ment aux instructions d installation du fabricant qui aurait t expos des substances ext rieures dont sans s y limiter les suivantes sable gravier ciment boue goudron...

Page 16: ...us es Qwik Jon Premier 201 0006 2 Trousse de r paration de l assemblage du tuyau de sortie 084993 3 Trousse de r paration du couvercle de r servoir 084994 4 Trousse de r paration du bo tier d interru...

Page 17: ...ue La pompe a un blocage d air S assurer que le trou d vent dans le tuyau d vacuation est d gag Soul vement vertical trop lev Changer la tuyauterie de l vacuation ou contacter le service du soutien te...

Page 18: ...courant de la tension appropri e est n cessaire pour alimenter la pompe en lectricit Eaux us es L acc s une canalisation d gout est obligatoire Le syst me Qwik Jon Premier n cessite un tuyau d vacuati...

Page 19: ...unit de pompage en alignant le tuyau d vacuation de la toilette avec l orifice d entr e de l unit de pompage S assurer que le soufflet comble l cart de mani re ad quate pour l installation Le r servoi...

Page 20: ...essitant un vent nettoyer et souder au solvant la tuyauterie d vent comme il se doit pour assurer une bonne ventilation Lors de l application de la soudure au solvant pour la conduite d vacuation s as...

Page 21: ...wik Jon Premier 8 Raccorder le tuyau d entr e provenant d un autre appareil sanitaire l entr e lat rale ou aux entr es lat rales du syst me Qwik Jon Premier U lisez une scie cloche 1 3 4 44 mm pour pe...

Page 22: ...TION Connectez tous les tuyaux d entr e au Qwik Jon Premier si vous le souhaitez Brancher le cordon d alimenta on dans une prise murale pour alimenter l appareil 9 Zoeller Co 2020 Tous droits r serv s...

Page 23: ...proc der l entre en ou l ouverture Cet quipement ne doit tre r par et entretenu que par un professionnel quali Re rez le tuyau d vent de chemin e et le tuyau d vacua on du haut du Qwik Jon Premier Zoe...

Page 24: ...11 Re rez le couvercle du Qwik Jon Premier Soulevez le bo er de l interrupteur et la pompe hors du r servoir Zoeller Co 2020 Tous droits r serv s...

Page 25: ...eur peut tre re r du bo er de l interrupteur pour d gager le o eur des d bris Le tuyau coud de refoulement peut tre d connect de la volute de la pompe pour tre d barrass des d bris Zoeller Co 2020 To...

Page 26: ...po max 126 m 413 pi Tuyau de 2 cm 1 po max 234 m 769 pi Tuyau de 1 9 cm po max 162 m 534 pi TAPE 7 T TE D BIT DYNAMIQUE TOTAL Mod le M tres Pieds Litres Gallons Zoeller Co 2020 Tous droits r serv s T...

Page 27: ...podr an presentar un riesgo de seguridad si el aislamiento se da ara o el extremo de la conexi n cayera en un rea h meda o mojada Aseg rese de que el circuito de suministro el ctrico de la bomba est...

Page 28: ...ra No se har ning n descuento a los cargos de env o da os mano de obra ni a los dem s gastos que puedan surgir debido al fallo del producto su reparaci n o reemplazo Esta garant a no se aplica y no ha...

Page 29: ...lir con todos los c digos vigentes aplicables Opci n manguera con abrazadera techo de pie techo de pie Subsuelo m nimo grueso vigas de piso Componente Descripci n 1 Qwik Jon Preimer Sewage Removal Sys...

Page 30: ...de la bomba Mantenga hacia abajo la palanca del tanque del inodoro durante 15 segundos Si la unidad no se limpia desen chufe y espere 30 minutos Enchufe nuevamente la unidad y repita Si la unidad toda...

Page 31: ...mm Si el piso no est nivelado utilice cemento hidr ulico o un material similar para nivelarlo Agua se necesitar un suministro de agua para que funcione el inodoro Por lo general es suficiente una l ne...

Page 32: ...uber as Quite el inodoro de la bomba y d jelo a un lado Colocar el inodoro frente a la unidad de bombeo alineando la descarga del inodoro con la entrada de la unidad Aseg rese de que el fuelle cubrir...

Page 33: ...no est n seguras Cuando utilice entradas laterales instale una v lvula de retenci n en la entrada l nea 1 Corte y ajuste en seco la tuber a y los conectores como se requiere para una tuber a de 1 DN2...

Page 34: ...ior del Qwik Jon Premier Copyright 2020 Zoeller Co Todos los derechos reservados 8 Conecte los tubos de entrada deseados de otros accesorios a las entradas laterales del Qwik Jon Premier Use una sierr...

Page 35: ...O 5 Conecte todas las tuber as de entrada al Qwik Jon Premier si lo desea Conecte el cable de alimentaci n a un enchufe de pared para energizar la unidad Copyright 2020 Zoeller Co Todos los derechos r...

Page 36: ...k Jon Premier Copyright 2020 Zoeller Co Todos los derechos reservados 10 Peligro mec nico y el ctrico Desconecte de la fuente de energ a el ctrica antes de manipular el equipo para inspecci n o manten...

Page 37: ...Copyright 2020 Zoeller Co Todos los derechos reservados 11 Qu tate la tapa del Qwik Jon Premier Levante la caja del interruptor y re re la bomba del tanque...

Page 38: ...se puede quitar de la carcasa del interruptor para limpiar el otador La tuber a del codo de descarga se puede desconectar de la voluta de la bomba para limpiarla Copyright 2020 Zoeller Co Todos los de...

Page 39: ...dimiento de la bomba 115V 60Hz 29 5pies 9m Cabeza de cierre 5 10 15 20 25 1 5 3 0 4 6 6 1 7 6 45 39 33 25 13 170 3 147 6 124 9 94 6 49 2 tuber a de 1 DN25 m x 106 32 m tuber a de 3 4 DN20 m x 69 21 m...

Reviews: