background image

6

© Copyright 2020 Zoeller

®

 Co. All rights reserved.

AQUANOT

®

 FIT FLOAT SWITCH

FIGURE 3

SK3186

FIT CONTROLLER FUNCTIONS

There are two buttons on the front of the controller.

 

- Silence/Reset

•  Can be pressed to silence current alarms for 24 hours.

• 

Can be held for 3+ seconds to reset (or clear) alarms and LEDs. Flashing LEDs for conditions such as bad/disconnected battery or 

power outage, for example, can’t be cleared by Silence/Reset. These conditions must be remedied to eliminate the LED indicator.

 

- Test

•  Will run the pump to determine if amp draw of pump is within range. 

• 

Controller is factory programmed to self-test the pump for several seconds every 24 hours. This schedule may be modified once the 

Fit is connected to the Z Control Cloud.

•  Pressing the test button will start the 24-hour timer for self-testing.

 

- Test and Silence/Reset

• 

Holding both buttons together for about 6 seconds will initiate a Factory Reset. This returns the firmware’s device configuration to 

the state in which it left the factory. Any over the air firmware updates that have been installed will be retained.

Solid 

Flashing

Off

System Ready

No Faults (Green)

AC off with No Faults 

(Green)

--

Battery

Charged (Green)

Low Battery (Red)

No AC Power

Charging (Yellow)
Bad Battery (Red)

DC pump

Pump Ran  

(Yellow)*

Pump Running (Yellow)

--

Pump Fault (Red)

Float Status

High Water (Red) 

Float Fault (Red)

--

Z Control

Connected

Searching

Broadcasting SSID or Dormant

* Note: will not persist if pump didn’t pump water.

   See also the laminated label affixed to the controller’s cord. This cord label also describes LED and 

 

   button functionality.

The LEDs will display information about the controller. 

LOCKING PIN MUST BE

INSTALLED UNDER FLOAT

ROD IN THIS LOCATION.

MOLEX 2-PIN CONNECTOR 

MOLEX 4-PIN CONNECTOR 

DISCHARGE TEE

REDUCER FITTING

CLAMP

CHECK VALVE ASSEMBLY

CLAMP

PUMP O-RING

CHECK VALVE O-RING

DC PUMP

BULLHEAD DISCHARGE TEE

CLAMP

CHECK VALVE ASSEMBLY

CLAMP

PUMP O-RING

CHECK VALVE O-RING

DC PUMP

PROPAK SYSTEMS

COMBO SYSTEMS

SK2962

FIGURE 4

AQUANOT FIT

Note: Upper rubber stop is usually not needed.

Summary of Contents for AQUANOT 508 Fit

Page 1: ... check the battery and battery connection at least once a month Batteries contain acid and caution must be taken when handling 6 Risk of electric shock These pumps have not been investigated for use in swimming pools and marine areas 7 Prop 65 Warning for California residents Cancer and Reproductive Harm www P65Warning ca gov 1 Makesurethereisaproperlygrounded115Vreceptacleavailable Do not use pri...

Page 2: ...gal rights and you may also have other rights which vary from state to state Discharge Feet of Head 5 1 5 m 10 3 m 15 4 6 m 28 85 m Flow GPM LPM 12 7 volts 43 163 35 132 27 102 Shut off Head This system is a backup to your primary sump pump It is designed to protect against flooding during power outages or primary pump failure This system is unique in that it has self testing and communication fea...

Page 3: ...ot to cross or short across the battery terminals with your wrench or any other metal object 13 Connect the DC pump s plug into the controller terminal 14 Plug the controller into the 115 V wall outlet The primary sump pump and the controller should be on separate circuits 15 Reconnect power to the primary sump pump 16 The Aquanot Fit Controller is designed for use with Z Control 1 Thepreferredmet...

Page 4: ...hecontrollerwillturnthepumponand off a few times before running the pump continuously This is to purge a suspected air lock If the high water float is removed unplugged the resulting controller and pump behaviors are the same as if it was turned on The alarm and red Float Status LED will be on until silenced andreset respectively If thereisaneedforthecontrollerto disregard the high water float for...

Page 5: ...F FLOAT ASSEMBLY MUST BE HIGHER THAN INTAKE OF DC BACKUP PUMP DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX AQUANOT FIT CONTROLLER OUTLET CONTROLLER HIGH WATER REED SENSOR OPERATIONAL FLOAT SWITCH 30 AMP FUSE HIGH WATER REED SENSOR BATTERY BOX DC PUMP 12 VOLT BATTERY SUPPLIED BY USER WHITE LEAD TO POSITIVE BLACK LEAD TO NEGATIVE CLAMP AQUANOT FIT CONTROLLER EXPLODED VIEW DC PUMP FIGU...

Page 6: ...r about 6 seconds will initiate a Factory Reset This returns the firmware s device configuration to the state in which it left the factory Any over the air firmware updates that have been installed will be retained Solid Flashing Off System Ready No Faults Green AC off with No Faults Green Battery Charged Green Low Battery Red No AC Power Charging Yellow Bad Battery Red DC pump Pump Ran Yellow Pum...

Page 7: ... Such a check is not required for maintenance free battery types 1 DC Pump won t run a Check for proper connections b Check all wire terminal points Clean if required c Check for low battery Service battery if required d Check 30 amp fuse on controller see fig 3 If fuse is blown replace with 30 amp automotive blade fuse e Remove pump Check for obstruction in pump preventing impeller from rotating ...

Page 8: ...nternet connection is necessary 4 When the captive screen opens see Figure C in next section use the Wifi Scan button to find the Wifi network you want the Fit to use select it from the list provided at the bottom of the screen you may need to scroll and type the Passphrase in the field The Z Control LED should be solid within a minute indicating successful connection to the router and the Z Contr...

Page 9: ...when the Fit is broadcasting its name or SSID The SSID is in the format ZCTL_Fit_xxxx where xxxx is the first 4 digits of your Fit s Device ID See Figure B The Fit s SSID will show up in your phone tablet computer s list of available WiFi networks and selecting it will give you direct connectivity to the Fit This is required in order to give your Fit the password credentials needed to connect to t...

Page 10: ... LED will flicker for up to 1 minute while the update is downloaded The Z Control LED will be solid and all other LEDs will turn off while the update is being installed After up to 1 minute the Fit will restart and return to normal operation The Fit s alert history on the Z Control Cloud will also be updated with the firmware upgrade information and nofication to email accounts will occur When you...

Page 11: ...so it is impossible to guarantee consistent quality A defective battery will never become fully charged and may damage the charging circuits of the controller It is for this reason that Zoeller offers its own line of batteries We offer both a water acid deep cycle battery and a maintenance free AGM battery which can run the pump continuously for over 5 hours These times are based on continuous pum...

Page 12: ...ts reserved MAIL TO P O BOX 16347 Louisville KY 40256 0347 SHIP TO 3649 Cane Run Road Louisville KY 40211 1961 502 778 2731 1 800 928 PUMP FAX 502 774 3624 Visit our website zoellerpumps com These are the original installation instructions ...

Reviews: