background image

7

© Copyright 2020 Zoeller

®

 Co. All rights reserved.

CONNECTING THE FIT TO Z CONTROL

®

By connecting the Fit to the Z Control

®

 Cloud using the built-in WiFi, the user can set up free alert messages via email, text, and mobile app “push” 

notifications. In addition, the user can verify the Fit’s readiness, remotely silence alarms and reset the unit, configure settings, and modify how 

notifications are sent. Other visual information such as input status and battery level are available through the web and app interfaces.
There are 2 ways to connect the Aquanot Fit to the Z Control

®

 cloud.  

1.  The simplest method is to use the Z Control

®

 mobile app. These instructions are below under “Use the Mobile App”.  

2.   The second method is to use your mobile device or computer to connect to the Fit directly. Instructions for connecting directly are 

provided below under “Use Your Mobile Device Or Computer To Connect Directly To The Fit Controller”.

Use the Mobile App (iOS and Android)
Before you begin:

• 

 Know what your WiFi network is named (i.e. its SSID) and its password. Double check you know the correct password and exactly how it 

is spelled, including capitalization. This will prevent the most common troubleshooting issues.

• 

 Verify that your mobile device has working WiFi and detects a strong signal from your WiFi network when you are standing next to the Fit.  

If the signal is questionable, your network may not be able to provide a stable connection for the Fit.

• 

Verify your WiFi network is connected to the internet and that it is broadcasting a visible, secure, 2.4Ghz network.

MAINTENANCE

TROUBLESHOOTING INFORMATION

1.  Inspect and test the system for proper operations at least every 3 

months.*

 

(a)  Green "system ready" indicator light should be on, indicating AC 

power is on and there are no alarm conditions.

 

(b)  Unplug the primary pump and the controller from the power supply.

 

(c)  Fill the sump with water to the “on” level for the DC pump. Allow 

the pump to run a few minutes.

 

(d)  The alarm will sound approximately 1 second after the pump 

starts 

to run.

 

(e)  Push the Silence/Reset button. The alarm will turn off.

 

(f)  The pump will shut off after the water level is lowered and the 

operational float drops 

to the "off" position.

 

(g)  Hold Silence/Reset button for 3 seconds to reset the controller 

and clear any alarms or indicators.

2.  Plug the controller and the primary pump into the wall outlet.

 

(a)   The primary pump will come on, lower the water to the 

normal 

operating level and shut off.

 

(b)   The battery light will be yellow when charging. The charger is 

replacing 

the energy consumed during the test. The green light 

will come on after the charger has replaced the energy consumed 
during the test.

*Electrolyte levels in wet cell batteries should be checked monthly. Such a 

check is not required for "maintenance free" battery types.

1.  DC Pump won’t run.

 

(a)  Check for proper connections.

 

(b)  Check all wire terminal points. Clean if required.

 

(c)  Check for low battery. Service battery if required.

 

(d)  Check 30 amp fuse on controller (see fig. 3). If fuse is blown, replace 

with 30 amp automotive blade fuse.

 

(e)  Remove pump. Check for obstruction in pump preventing impeller 

from rotating.

 

(f)  Float switch was not “on” for more than 1 second. A quick up/

down of a switch will not turn the pump on because the controller 

is designed with “splash activation protection”.

 

(g)  During a float fault, the operational float is disregarded until the 

controller is reset.

2.  Pump runs but moves very little or no water.

 

(a)  Check for low battery. Battery will recharge if green System Ready 

LED indicates power has been restored and the float switch is in 

the off position.

 

(b)  If immediate usage is required, remove and replace dead battery 

with a fully recharged battery.

 

(c)  Under certain conditions the pump may continue to run on a low 

battery without sufficient power to remove water. Pump will stop 

running once battery is below minimum voltage threshold.

 (d) 

CAUTION

 Weak batteries can be recharged but may not store 

sufficient energy for full service. A weak, recharged battery can 

only be detected by reduced pumping time or by professional load 

testing equipment. The battery should be checked by a qualified 

battery dealer.

 

(e)  Verify pump is connected completely.

 

(f)  Check to make sure pump weep hole is clear and unit is not airlocked.

 

(g)  Make sure discharge piping is not blocked.

3.  Pump cycles too frequently.

 

(a)  Check positions of rubber stops on the operational float rod and 

adjust if necessary.

4.  Pump runs, but pumps water intermittently.

 

(a)  Pump may be air locking. Check flow of water incoming to sump. If 

water is entering the sump at a high velocity creating a turbulent 

condition, a mixture of air and water may cause a complete or partial 

air lock and reduce or stop the flow of water in the discharge pipe.

 

(b)  Baffle the incoming stream of water to reduce turbulence. Diverting 

water stream against wall of basin usually corrects an air lock 

problem.

5.  Water level stays high. DC Pump continues to run.

    (a)  Battery is low or pump may have blockage in screen, impeller, or 

piping system.

    (b)  If power has been restored and water in sump remains high check 

primary pump. Service if required.

6.  Alarm sounds during battery recharge cycle.

    (a)  To silence alarm if alarm will not reset, unplug the charger from 

115 V wall outlet, then disconnect the black lead from charger 

on negative (-) battery post. Check battery. Replace if necessary. 

Reconnect and refer to Installation Instructions.

NOTE: The Z Control

®

 Cloud may provide additional information.

To perform a Factory Reset, hold the Silence and Test buttons together. A Factory Reset restores all settings to their original setting. Be sure all 

switches, pump, battery and AC connections are good before the Factory Reset. 

Summary of Contents for AQUANOT 508 Fit

Page 1: ... check the battery and battery connection at least once a month Batteries contain acid and caution must be taken when handling 6 Risk of electric shock These pumps have not been investigated for use in swimming pools and marine areas 7 Prop 65 Warning for California residents Cancer and Reproductive Harm www P65Warning ca gov 1 Makesurethereisaproperlygrounded115Vreceptacleavailable Do not use pri...

Page 2: ...gal rights and you may also have other rights which vary from state to state Discharge Feet of Head 5 1 5 m 10 3 m 15 4 6 m 28 85 m Flow GPM LPM 12 7 volts 43 163 35 132 27 102 Shut off Head This system is a backup to your primary sump pump It is designed to protect against flooding during power outages or primary pump failure This system is unique in that it has self testing and communication fea...

Page 3: ...ot to cross or short across the battery terminals with your wrench or any other metal object 13 Connect the DC pump s plug into the controller terminal 14 Plug the controller into the 115 V wall outlet The primary sump pump and the controller should be on separate circuits 15 Reconnect power to the primary sump pump 16 The Aquanot Fit Controller is designed for use with Z Control 1 Thepreferredmet...

Page 4: ...hecontrollerwillturnthepumponand off a few times before running the pump continuously This is to purge a suspected air lock If the high water float is removed unplugged the resulting controller and pump behaviors are the same as if it was turned on The alarm and red Float Status LED will be on until silenced andreset respectively If thereisaneedforthecontrollerto disregard the high water float for...

Page 5: ...F FLOAT ASSEMBLY MUST BE HIGHER THAN INTAKE OF DC BACKUP PUMP DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX AQUANOT FIT CONTROLLER OUTLET CONTROLLER HIGH WATER REED SENSOR OPERATIONAL FLOAT SWITCH 30 AMP FUSE HIGH WATER REED SENSOR BATTERY BOX DC PUMP 12 VOLT BATTERY SUPPLIED BY USER WHITE LEAD TO POSITIVE BLACK LEAD TO NEGATIVE CLAMP AQUANOT FIT CONTROLLER EXPLODED VIEW DC PUMP FIGU...

Page 6: ...r about 6 seconds will initiate a Factory Reset This returns the firmware s device configuration to the state in which it left the factory Any over the air firmware updates that have been installed will be retained Solid Flashing Off System Ready No Faults Green AC off with No Faults Green Battery Charged Green Low Battery Red No AC Power Charging Yellow Bad Battery Red DC pump Pump Ran Yellow Pum...

Page 7: ... Such a check is not required for maintenance free battery types 1 DC Pump won t run a Check for proper connections b Check all wire terminal points Clean if required c Check for low battery Service battery if required d Check 30 amp fuse on controller see fig 3 If fuse is blown replace with 30 amp automotive blade fuse e Remove pump Check for obstruction in pump preventing impeller from rotating ...

Page 8: ...nternet connection is necessary 4 When the captive screen opens see Figure C in next section use the Wifi Scan button to find the Wifi network you want the Fit to use select it from the list provided at the bottom of the screen you may need to scroll and type the Passphrase in the field The Z Control LED should be solid within a minute indicating successful connection to the router and the Z Contr...

Page 9: ...when the Fit is broadcasting its name or SSID The SSID is in the format ZCTL_Fit_xxxx where xxxx is the first 4 digits of your Fit s Device ID See Figure B The Fit s SSID will show up in your phone tablet computer s list of available WiFi networks and selecting it will give you direct connectivity to the Fit This is required in order to give your Fit the password credentials needed to connect to t...

Page 10: ... LED will flicker for up to 1 minute while the update is downloaded The Z Control LED will be solid and all other LEDs will turn off while the update is being installed After up to 1 minute the Fit will restart and return to normal operation The Fit s alert history on the Z Control Cloud will also be updated with the firmware upgrade information and nofication to email accounts will occur When you...

Page 11: ...so it is impossible to guarantee consistent quality A defective battery will never become fully charged and may damage the charging circuits of the controller It is for this reason that Zoeller offers its own line of batteries We offer both a water acid deep cycle battery and a maintenance free AGM battery which can run the pump continuously for over 5 hours These times are based on continuous pum...

Page 12: ...ts reserved MAIL TO P O BOX 16347 Louisville KY 40256 0347 SHIP TO 3649 Cane Run Road Louisville KY 40211 1961 502 778 2731 1 800 928 PUMP FAX 502 774 3624 Visit our website zoellerpumps com These are the original installation instructions ...

Reviews: