CARBON MONOXIDE DETECTORS

Some battery types used in battery backup systems, regardless of brand or manufacturer, have the potential to give off gaseous by-products when 

charging. Some of these by-products can produce a rotten egg odor. Also, some of these by-products can cause a CO detector to falsely activate. 

In order to help prevent false activation, Zoeller Pump Company recommends moving the battery as far away from the CO detector as possible or, 

if necessary, venting the battery to the exterior. Zoeller Pump Company provides the previous statements only as guidelines to help prevent false 

activation of the CO detector. In no way are these statements intended to supersede the instructions that accompany the detector, nor do they 

supersede advice from the CO detector manufacturer.
If the audible alarm associated with your CO detector is activated, we recommend the following actions:

1)  Take immediate action for personal safety as recommended in the CO detector literature.

2)  Contact the appropriate agency to determine if the CO is being produced by your furnace, water heater, or any other device which uses natural 

gas.

3)  If you are certain that no CO is being produced, a charging battery may be producing gaseous by-products capable of causing the CO detector 

to activate. Contact the manufacturer and ask for recommendations to prevent the alarm activation.

There are millions of batteries manufactured each year, so it is impossible to guarantee consistent quality. A defective battery will never 

become fully charged and may damage the charging circuits of the controller. It is for this reason that Zoeller offers its own line of batteries.  

We offer both a water/acid deep-cycle battery and a maintenance-free AGM battery which can run the pump continuously for over 5 hours.  

These times are based on continuous pumping at 8' (2.4 m) of static head. Actual times will vary depending on static head, volume of water 

entering the pit, and the condition of the battery.

Follow these recommendations:

•  Use a B.C.I. size 27 deep-cycle battery, 175 minute reserve capacity, or larger

•  Replace your battery every 3 years

•  Do not let corrosion build up on the battery terminals

•  To check specific gravity, follow the instructions on a hydrometer (wet cell batteries only)

•  Use of the included plastic battery box is recommended to keep the battery safe and clean. 

PROTECT YOUR WARRANTY:  

•  Water level in batteries must be checked once a month (wet cell batteries only)

THE AQUANOT

®

 

BATTERY

Congratulations! Your Fit is online. Be sure you have added the contact information for phone numbers and email adresses that should receive 

notifications. This can done by selecting "Manage Contacts" from the main menu (the square with 3 lines in the upper right corner). You can also 

edit how each device sends out notifications from the device's "Alarm Settings" tab. You can now open the product’s configuration by clicking the 

“View” button to modify the Fit’s device and notification settings. You can also install the Z Control

®

 mobile app on your mobile device (Android and 

iOS versions available, search “Z Control

®

” in the app stores).  

Summary of Contents for AQUANOT 508 Fit

Page 1: ... check the battery and battery connection at least once a month Batteries contain acid and caution must be taken when handling 6 Risk of electric shock These pumps have not been investigated for use in swimming pools and marine areas 7 Prop 65 Warning for California residents Cancer and Reproductive Harm www P65Warning ca gov 1 Makesurethereisaproperlygrounded115Vreceptacleavailable Do not use pri...

Page 2: ...gal rights and you may also have other rights which vary from state to state Discharge Feet of Head 5 1 5 m 10 3 m 15 4 6 m 28 85 m Flow GPM LPM 12 7 volts 43 163 35 132 27 102 Shut off Head This system is a backup to your primary sump pump It is designed to protect against flooding during power outages or primary pump failure This system is unique in that it has self testing and communication fea...

Page 3: ...ot to cross or short across the battery terminals with your wrench or any other metal object 13 Connect the DC pump s plug into the controller terminal 14 Plug the controller into the 115 V wall outlet The primary sump pump and the controller should be on separate circuits 15 Reconnect power to the primary sump pump 16 The Aquanot Fit Controller is designed for use with Z Control 1 Thepreferredmet...

Page 4: ...hecontrollerwillturnthepumponand off a few times before running the pump continuously This is to purge a suspected air lock If the high water float is removed unplugged the resulting controller and pump behaviors are the same as if it was turned on The alarm and red Float Status LED will be on until silenced andreset respectively If thereisaneedforthecontrollerto disregard the high water float for...

Page 5: ...F FLOAT ASSEMBLY MUST BE HIGHER THAN INTAKE OF DC BACKUP PUMP DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX AQUANOT FIT CONTROLLER OUTLET CONTROLLER HIGH WATER REED SENSOR OPERATIONAL FLOAT SWITCH 30 AMP FUSE HIGH WATER REED SENSOR BATTERY BOX DC PUMP 12 VOLT BATTERY SUPPLIED BY USER WHITE LEAD TO POSITIVE BLACK LEAD TO NEGATIVE CLAMP AQUANOT FIT CONTROLLER EXPLODED VIEW DC PUMP FIGU...

Page 6: ...r about 6 seconds will initiate a Factory Reset This returns the firmware s device configuration to the state in which it left the factory Any over the air firmware updates that have been installed will be retained Solid Flashing Off System Ready No Faults Green AC off with No Faults Green Battery Charged Green Low Battery Red No AC Power Charging Yellow Bad Battery Red DC pump Pump Ran Yellow Pum...

Page 7: ... Such a check is not required for maintenance free battery types 1 DC Pump won t run a Check for proper connections b Check all wire terminal points Clean if required c Check for low battery Service battery if required d Check 30 amp fuse on controller see fig 3 If fuse is blown replace with 30 amp automotive blade fuse e Remove pump Check for obstruction in pump preventing impeller from rotating ...

Page 8: ...nternet connection is necessary 4 When the captive screen opens see Figure C in next section use the Wifi Scan button to find the Wifi network you want the Fit to use select it from the list provided at the bottom of the screen you may need to scroll and type the Passphrase in the field The Z Control LED should be solid within a minute indicating successful connection to the router and the Z Contr...

Page 9: ...when the Fit is broadcasting its name or SSID The SSID is in the format ZCTL_Fit_xxxx where xxxx is the first 4 digits of your Fit s Device ID See Figure B The Fit s SSID will show up in your phone tablet computer s list of available WiFi networks and selecting it will give you direct connectivity to the Fit This is required in order to give your Fit the password credentials needed to connect to t...

Page 10: ... LED will flicker for up to 1 minute while the update is downloaded The Z Control LED will be solid and all other LEDs will turn off while the update is being installed After up to 1 minute the Fit will restart and return to normal operation The Fit s alert history on the Z Control Cloud will also be updated with the firmware upgrade information and nofication to email accounts will occur When you...

Page 11: ...so it is impossible to guarantee consistent quality A defective battery will never become fully charged and may damage the charging circuits of the controller It is for this reason that Zoeller offers its own line of batteries We offer both a water acid deep cycle battery and a maintenance free AGM battery which can run the pump continuously for over 5 hours These times are based on continuous pum...

Page 12: ...ts reserved MAIL TO P O BOX 16347 Louisville KY 40256 0347 SHIP TO 3649 Cane Run Road Louisville KY 40211 1961 502 778 2731 1 800 928 PUMP FAX 502 774 3624 Visit our website zoellerpumps com These are the original installation instructions ...

Reviews: