13. Check inlet and outlet for correct water flow by matching arrows on valve head and
on manifold (especially if replacing existing unit).
Install in direction of arrows.
14. Diagram shows the valve with bypass and manifold installed. Install bypass and
manifold as follows:
A) Remove metal clips from side of control valve and bypass valve by removing
screws.
B) Apply silcone lubricant to both o-rings on control valve and bypass valve.
C) Slide bypass valve onto control valve, making sure knobs are facing up.
D) Slide manifold onto bypass valve, making sure inlet/outlet labels face up.
E) Secure all four clips on control valve, bypass valve and manifold with screws.
15. Diagram shows a 3 valve by-pass system. Many new homes are plumbed water
softener ready in this manner.
16. Before installing 3/4” fittings on the inlet and outlet of the manifold, wrap the
manifold threads three times around with teflon tape. Install fittings.
DO NOT OVER TIGHTEN!
17. Soldering is no longer required to plumb with copper pipe. Instead use compression
fittings. Connect plumbing as required for the specific application.
18. Typical finished installation using rigid copper pipe. Make sure bypass is in the
service position to ensure household service of treated water.
Outlet
Metal
Clip
Metal
Clip
Metal
Clip
Metal
Clip
90°
Elbow
By-Pass
Valve
Inlet
Drain
Connection