© Copyright 2002 Zoeller Co. All rights reserved.
15
MAINTENANCE
1. SALT REFILL - During each regeneration of
the water softener a specific amount of salt is
consumed, thus requiring periodic replenish-
ment. The frequency of this depends upon
the regeneration schedule. Always replenish
salt before the supply is exhausted to ensure
a continuous supply of softened water.
We suggest using a pellet type salt or grade
A rock salt that contains no dirt or sediment.
Fill tank about 3/4 full. Do not pack full and
do not use block salt. Potassium chloride
may be used.
2. PREVENTING IRON FOULING OF RESIN
BED - If iron is present in the water supply,
the softener will eventually become iron
fouled, resulting in reduced softening capac-
ity and rust stained fixtures. Use a type of
salt available on the market that contains iron
control agents to aid in cleansing the resin
bed.
3. BRINE TANK CLEAN OUT - To prevent serv-
ice problems, the brine tank should be emp-
tied and cleaned when dirt and other insol-
ubles accumulate.
THIS CLEAN OUT
SHOULD BE DONE WHEN THE SALT
LEVEL IS LOW.
4. PERIODICALLY CHECK THE TIME OF DAY
SETTING - Power outages will cause TIME
OF DAY timer setting to become incorrect.
To reset, refer to SETTING THE CONTROL
VALVE.
5. CHANGE OF OPERATING CONDITIONS -
Should your family size, your water usage
habits or your water quality change, the
regeneration program setting may have to be
adjusted.
344-0006
DELUXE UNDERCOUNTER FOR TASTE, ODORS AND MANY OTHER
CONTAMINANTS
344-0005
“BOTTLED WATER FACTORY” FOR EVERY OUTLET IN YOUR HOME
343-0005
REVERSE OSMOSIS FOR LEAD, NITRATES, SALT & OTHER TDS
OTHER FINE QUALITY PRODUCTS AVAILABLE BY ZOELLER