9
Pressure
gauge
Air release valve
Set to
18 psi
2
2. Use a pressure gauge to ensure it’s set to 18
PSI.
a. Use a tire pump to adjust the PSI to 18 PSI
b. If water leaks from the air release valve,
replace the pressure tank.
IL1365
Glue
Adapter
Pipe
1
1. Most pressure tanks will have a 1 in. inlet
elbow on the bottom. Connect to this elbow
with a 1 in. MPT x 1 in. slip (glue) adapter and
short piece of pipe.
TANK TO HOUSE CONNECTION
Glue
1 in. Pipe
3
IL1366
Glue
Elbow
2
3. Attach a 1 in. pipe (not included) to the
elbow.
2. Attach a 1 in. elbow (not included) to the pipe.