5
IL1472
Water Level
25 ft.
Max
Suction
Lift
1 in.
Discharge Pipe
1-1/4 in.
Suction
Pipe
Discharge
to Home
Pipe
Support
Drive Point
Check
Valve
2
IL1105
1 in. Discharge
1-1/4 in.
Suction
Ventilation -
Ventilation and drainage must be provided to prevent damage to the motor from heat
and moisture.
Freezing -
Pump and all piping must be protected from freezing. If freezing weather is forecast, drain
pump or remove completely from the system.
Water Supply -
The water source must be able to supply enough water to satisfy the capacity of
pump and water needs. See performance chart on page 2.
Suction Lift -
Suction lift is the vertical distance from the lowest level of the water to the pump intake.
Pump will move water as long as it is within 25 vertical ft. of the water source.
Horizontal Distance -
The horizontal distance is the horizontal measurement between pump suction
and the water source. This distance may affect the ability of pump to operate. If it is more than 100 ft.,
call the manufacturer for assistance: 1-800-584-8089.
2. Jet pumps can also be used with dug wells,
driven wells, or with cisterns or lakes.
Pipe And Fittings -
Use galvanized steel or
NSF PW Schedule 40 PVC pipe and fittings.
This material is designed for water pressure and
will seal against air and water under pressure.
Do not use DWV fittings, as these are designed
for drains without pressure and will not seal
properly.
CAUTION:
The entire system must be air
and water tight for efficient operation, and to
maintain prime.
Wire Size -
The wire size is determined by the distance from the power source to the pump motor
and the horsepower rating of the motor. See the wire chart in ELECTRICAL CONNECTIONS for
proper wire size.