17
IL1129
IMPORTANT:
If the pump fails to prime
within five minutes:
Turn power off at the breaker box and check
all pipe connections for leaks. All connections
must be water and air tight in order for pump to
operate.
All piping from the well to the pump should slope
slightly upward with no sagging. Support suction
pipe between water source and pump. Unions in
the suction line near the pump and well will aid in
servicing. Be sure to leave enough room so that
wrenches can be used easily.
NOTE
: Look for leaks or a milky color in the
discharged water, which indicates an air leak.
Re-prime if necessary, following steps 1 through
6 above. Reset breaker at the breaker box. All
connections must be water and air tight in order
for pump to operate.
CARE AND MAINTENANCE
Winterizing
CAUTION:
Drain the entire system if
there is danger of freezing. A drain plug is
provided at the bottom of the pump case for
this purpose.
IL1111
PREVENT
PUMP
DAMAGE!
Remove plug
in freezing
weather
1