background image

H0412400.A - EN - 2013-02

3

1. Information before installing

1.1 General delivery terms and conditions

All equipment, even postage and packing paid, travels at the risks and perils of the recipient. Written reserves should be 
made on the transporter’s delivery documents if damage during transport is discovered by the recipient (confirmed by 
registered letter to the transporter within 48 hours).

1.2 Contents

TRi® Control box

TRi® cell

Flow controller kit

Bag of accessories

1.3 Technical specifications

Power supply voltage

230Vac-50Hz

Electric power

195W

Protection index

IP23

Box size (l x h x d)

31 x 33 x 11 cm

Cell size (L x d)

30 x 10 cm

Weight (box + cell)

7 Kg

Minimum

Maximum

Flow through the cell

5m³/h

18m³/h

Pressure in the cell

/

2,75 bars

Operating water temperature 

5 °C

40 °C

2. Installation

2.1 Preparing the pool: water balance

The TRi® is designed to disinfect pool water using its salt water chlorination function.
It is essential that the pool water balance is controlled and adjusted before installing the appliance. Making sure that the 
pool water balance is correct from the very start will reduce the likelihood of encountering problems on the first days of 
operation or during the season the pool is in use. 

Even though it is an autonomous system, it is essential to regularly analyse the water to check the water balance 

parameters.

Unit

Recommended 

values

To increase

To reduce

Test frequency 

(in the season)

pH

/

7,2 – 7,4

Add pH+ or use auto-

matic regulation

Add pH- or use auto-

matic regulation

Weekly

Free chlorine

mg/L or ppm

0,5 – 2

Increase the TRi’s® 

chlorine production or 

use the Boost mode

Reduce chlorine pro-

duction

Weekly

TAC

(alkalinity or

buffer power)

°f (ppm)

8 – 15

(80 – 150)

Add alkaline corrector

(Alca+ or TAC+)

Add hydrochloric

acid

Monthly

Summary of Contents for TRi

Page 1: ...H0412400 A 2013 02 Instructions for installation and use English...

Page 2: ...r be held liable in the event of failure to comply with applicable local standards It is important that this appliance is handled by skilled and apt persons both physically and men tally with prior kn...

Page 3: ...ns 3 2 Installation 3 2 1 Preparing the pool water balance 3 2 2 Installing the control box 4 2 3 Installing the cell 4 2 4 Installing the flow controller 4 2 5 Electric connections 5 3 Use 7 3 1 User...

Page 4: ...2 Installation 2 1 Preparing the pool water balance The TRi is designed to disinfect pool water using its salt water chlorination function It is essential that the pool water balance is controlled an...

Page 5: ...avoid load loss If you installed the cell on a by pass it is recommended to fit a check valve downstream from the cell and not a manual valve to avoid any risk of incorrect handling The two red wires...

Page 6: ...n the female connector located under the TRi box is designed for the direct connection of a fil tering pump 230Vac 50Hz maximum consumption 9A In this case use the supplied corresponding male connecto...

Page 7: ...wire to prevent it from being pulled off Depending on the brand and type of external automation system complete the following connections for the connec tion cable 7 Zodiac AquaLink TRi Jandy AquaLin...

Page 8: ...e production starts When the Boost mode is activated the rated chlorine production settings are temporarily overridden and the TRi chlorinator will operate for a total of 24 hours at a 100 chlorine pr...

Page 9: ...e is displayed in a 24 hour format 3 2 2 Programming Menu Timers The TRi chlorinator has two programmers to control chlorine production times These are called Timers or Operating time intervals Timer...

Page 10: ...lled to explain what to do Once the automatic scrolling is complete the TRi automatically returns to the TROUBLESHOOTING menu 3 2 4 External controller menu Automation Domotics The automation system m...

Page 11: ...effective electrode self cleaning Consult your reseller if you are in this situation professional access 4 2 Wintering The TRi chlorinator has a protective system to limit chlorine production under ba...

Page 12: ...an error code but an infor mation message Wait for about 10 minutes and chlorine production will resume automatically at the previously set level To cancel the CHECK CELL and PROD FAULT error messages...

Page 13: ...61558 2 6 1997 Safety of power transformers power supply units reactors and similar products Particular requirements for safety isolating transformers and power supply units incorporating safety isola...

Page 14: ...ease contact your retailer ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer www zodiac poolcare com Zodiac Pool Care Europe BP 90023 49...

Reviews: