USING THE BUILD-IN CLOCK AND TIMERS

When it comes to chlorination, every pool is different. To get what’s right for you, 

you will need to set the unit’s clock and timers. 

SETTING THE CLOCK

1.  Press the 

 button to enter the MAIN MENU.

2. Use 

 / 

 buttons and scroll to SET CLOCK.

3. Press 

.

4. Use 

 / 

 buttons to set the hours.

5. Press 

 to save the hours.

6.  Use the 

 / 

 buttons to set the minutes.

7. Press 

 to save the minutes.

  TRi-XO will then return to the MAIN MENU.

8. Press 

 to return to the operating screen.

NOTE:

 The time is displayed in 24 Hour format

Summary of Contents for TRi-XO CROSSOVER

Page 1: ...CHLORINATOR USE WITH SALT AND MINERAL SALTS...

Page 2: ...ly increase the risk of fatal hyperthermia DANGER To reduce the risk of severe injury or death do not remove the suction fittings of your spa or hot tub Never operate a spa or hot tub if the suction f...

Page 3: ...ian before using a spa f Persons using medication should consult a physician before using a spa or hot tub since some medication may induce drowsines while other medication may affect heart rate blood...

Page 4: ...you want to have a more luxurious feeling pool Zodiac Element mineral salts include magnesium chloride which has been used for centuries in mineral spa resorts across the world Magnesium has been ass...

Page 5: ...surized water spray such as that from irrigation sprinklers mechanical impacts and or damage and inaccessible to children 4 Using screws provided fasten the bracket securely to the wall and position t...

Page 6: ...ltration times 9 Once all connections are together press the mains power switch to ON Use the following UI buttons to access and select all menus and commands ON OFF Turn Chlorinator on off UP DOWN Sc...

Page 7: ...creen once the unit is powered up 1 Use to scroll to the right selection 2 Press to set the software to your preference Note If the choice selected is wrong or you wish to change at any future time yo...

Page 8: ...timers SETTING THE CLOCK 1 Press the button to enter the MAIN MENU 2 Use buttons and scroll to SET CLOCK 3 Press 4 Use buttons to set the hours 5 Press to save the hours 6 Use the buttons to set the m...

Page 9: ...or comes with two inbuilt timers that switch the filtration and chlorination system on and off as required During swimming season consider running the system for around 8 hours a day This can be incre...

Page 10: ...Press to select the timer you wish to set Timer 1 or Timer 2 5 Press 6 Press to set the hours on time 7 Press to save the hours 8 Press to set the minutes on time 9 Press to save the minutes 10 Press...

Page 11: ...ol chlorine generation using an external time switch If the chlorine generator is turned ON and the external timer fails to switch the mains power off within 30 hours the Zodiac TRi XO will automatica...

Page 12: ...ring the pool s chlorine level over time and then adjusting the output percentage accordingly will ensure optimum sanitation To set Chlorine Output levels 1 Press the button to turn the chlorine gener...

Page 13: ...00 ppm at 27 C To increase Add chlorine or increase output of equipment Add buffer or soda ash sodium carbonate Add sodium bicarbonate Add calcium chloride Add Cyanuric acid Add Salt To decrease Add m...

Page 14: ...er to the TRi XO unit on 2 Wait for the start up sequence to complete 3 Press the button 4 Press the button to scroll down to CONTROLLER 5 Press to enter the controller menu 6 Press to highlight the c...

Page 15: ...installer Before any wiring connections disconnections ensure mains power is removed from both the controller and the Zodiac TRi XO unit When connected to a controller the TRi XO Chlorine generator a...

Page 16: ...size of the cable being used 6 Attach a cable tie to the controller cable as shown in the diagram The wiring colour codes are outlined below Depending on the make of the Controller make the following...

Page 17: ...G CONNECTIONS To verify the connection 1 Switch the TRi XO unit on and check the controller setting follow instructions under SETTING CONTROLLER 2 Re test the connection Note For safety reasons the Zo...

Page 18: ...the screen Note Low or Winter mode cannot be selected when TRi is being controlled by an external controller AUTOMATIC SETTING The Zodiac TRi XO can be connected to the valves of an automatic pool spa...

Page 19: ...un at 100 for a cumulative total of 24 hours before reverting to the previous output setting NOTE The BOOST mode cannot be engaged under the following curcumstances 1 If the TRi XO is in the OFF opera...

Page 20: ...nu 3 Press to enter the HELP DIAG menu 4 Once in the HELP DIAG menu use the buttons to scroll to the error warning that has been displayed 5 Press A number of suggested solutions are momentarily displ...

Page 21: ...terminals 3 We recommend using Zodiac Salt Chlorinator Cell Cleaner to clean the electrode However you can mix your own by carefully adding one 1 part of Hydrochloric Muriatic acid to ten 10 parts wat...

Page 22: ...ing Chlorine production is halted when this warning is displayed Check to see if there is water flow through the cell housing if there is no flow or very low flow there may be a problem with the pump...

Page 23: ...__________________________________________ _______________________________________________________ _______________________________________________________ _____________________________________________...

Page 24: ...provements specifications may change without notice Improper use could affect performance and void warranty Copyright Fluidra Australia Ltd 2020 H0494700 REVB For full warranty terms and conditions an...