background image

Figure 13.  Backplate assembly

4. 

Place the backplate o-ring side down and force 

the ceramic seal out using a screwdriver or drift.

5. 

Turn the backplate o-ring side up and insert the 

new ceramic seal side into the backplate. Use 

great care to press the seal in squarely with your 

fingers. The ceramic is easily damaged and must 

be pressed in using only your fingers or soft 

tools. Do not use any lubricant other than water 

and soap solution.

6. 

Install the motor following the steps in

 

Section 6.2.5, Motor Replacement

.

7. 

Install the backplate following the steps in

 

Section 6.2.3, Impeller Replacement

.

6.2.5  Motor replacement

Caution

To ensure continued safety and reliable operation, 

Zodiac Pool Systems, Inc. requires that you replace 

the motor with a motor that has the identical HP rating 

and service factor (Zodiac Pool Systems, Inc. ap-

proved only).

 Warning

To avoid the risk of property damage, severe personal 

injury, or death, turn off the pump and switch off the 

circuit breaker to the pump motor before beginning 

this procedure.

1. 

Have a qualified service technician or electrician 

properly disconnect the electrical wiring at the 

pump motor.

2. 

To disassemble the pump housing from the 

motor, follow steps 1 through 8 in 

Section 6.2.2, 

Impeller Removal

.

3. 

Place the backplate motor assembly o-ring side 

down and unscrew the four (4) 9/16" screws and 

remove the motor. 

notE

  Before removing the backplate, note the alignment of 

the backplate to the motor. See Figure 13.

4. 

If installing a new motor, remove the protective 

plastic cap from the motor shaft. Place the motor 

on the backplate so that the opening in the motor 

faces the bottom of the backplate. The starting 

capacitor on the motor should be at the  

12 o'clock position. 

5. 

Replace the four (4) bolts and washers holding 

the backplate to the motor. 

6. 

To reassemble the pump after replacing the 

motor, follow steps 1 through 14 of 

Section 6.2.3, 

Impeller Replacement

.

7. 

Have a qualified service technician or electrician 

properly connect the electrical wiring at the 

pump motor.

notE

  Zodiac Pool Systems, Inc. recommends that the 

mechanical seals be replaced at the same time the 

motor is replaced. See 

Section 6.2.4, Mechanical Seal 

Replacement, 

for details.

Page 18 

ENGLISH

Jandy

®

 Pro Series Stealth

 Pumps   

|

   Operation Manual

Bolts and

Washers (4)

Backplate

Motor

Starting

Capacitor

Summary of Contents for Stealth Jandy Pro Series

Page 1: ...of the instructions in this manual can be followed exactly Before installing this product read and follow all warning notices and instructions that accompany this product Failure to follow warning not...

Page 2: ...Page 2 ENGLISH Jandy Pro Series Stealth Pumps Operation Manual...

Page 3: ...Routine Maintenance 13 5 2 Winterizing the Pump 13 Section 6 Troubleshooting and Repair 14 6 1 Troubleshooting 14 6 2 Service Technician Maintenance 15 Section 7 Product Specifications and Technical...

Page 4: ...rtified electrician or a qualified swimming pool service technician WARNING RISK OF ELECTRIC SHOCK FIRE PERSONAL INJURY OR DEATH Connect only to a branch circuit that is protected by a ground fault ci...

Page 5: ...ump dry Running the pump dry for any length of time will cause severe damage and will void the warranty WARNING Chemical spills and fumes can weaken pool spa equipment Corrosion can cause filters and...

Page 6: ...shall not allow for separate or independent shutoff or isolation of each drain See Figure 1 on page 7 More than one 1 pump can be connected to a single suction line as long as the requirements above a...

Page 7: ...al contact Zodiac Pool Systems Inc Zodiac at 800 822 7933 For address information see the back cover of this manual 2 2 Description SHP Pumps are designed to meet the needs of today s more hydraulical...

Page 8: ...on 1 Upon receipt of the pump check the carton for damage Open the carton and check the pump for concealed damage such as cracks dents or a bent base If damage is found contact the shipper or distribu...

Page 9: ...rom the pump 5 The piping must be well supported and not forced together where constant stress will be experienced 6 Always use properly sized valves Jandy Pro Series Diverter Valves and Ball Valves t...

Page 10: ...harp edges on terminals require extra protection To prevent wire nuts from loosening tape them using a suitable listed UL ETL CSA electrical insulating tape For safety and to prevent entry of contamin...

Page 11: ...elps to place the o ring on the step rather than to roll it on That prevents it from rolling off NOTE The blue o ring sits approximately away from the seal See Figure 4 4 Carefully install the lid mak...

Page 12: ...r Running the pump dry for any length of time can cause severe damage to both the pump and motor and will void the war ranty If this is a new pool installation make sure all piping is clear of constru...

Page 13: ...fy that all valves have been returned to the proper position for normal operation 9 Open the pressure release valve on the filter and make sure it is clean and ready for operation 10 Turn on the power...

Page 14: ...ion nuts to the pump With clean union o rings hand tightening of the unions should create a seal If the unions still do not seal gently tighten with a large pair of tongue and groove pliers Do not ove...

Page 15: ...ch off the circuit break ers at the power source Severe personal injury or death may occur if the pump starts while your hand is inside the pump 1 Turn off the pump Switch off the circuit breaker to t...

Page 16: ...new carbon face seal half see Figure 11 on the motor shaft using a twisting motion Make sure the carbon surface is facing toward the ceramic ring in the backplate CAUTION VERY IMPORTANT Grasp the low...

Page 17: ...screw is a left hand threaded screw Therefore turn the screw counter clockwise to tighten 3 Replace the motor shaft cover by inserting the cover tabs into the slots and rotating the cover 90 clockwis...

Page 18: ...hnician or electrician properly disconnect the electrical wiring at the pump motor 2 To disassemble the pump housing from the motor follow steps 1 through 8 in Section 6 2 2 Impeller Removal 3 Place t...

Page 19: ...1 Single speed Motor Hardware SHPF 3 Phase 1 0 R0479101 1 Single speed Motor Hardware SHPF 3 Phase 1 5 R0479102 1 Single speed Motor Hardware SHPF 3 Phase 2 0 R0479103 1 Single speed Motor Hardware SH...

Page 20: ...ing Seal All R0445800 9 Blue Pressure Test O ring All R0479000 10 Pump Debris Filter Basket All R0445900 11 Drain Plug w O ring Set of 2 All R0446000 12 Tail Piece 2 by 2 O ring Coupling Nut Set of 2...

Page 21: ...240 250 Flow Rate Gallons Per Minute GPM Total Dynamic Head FEET of H2O 0 5 10 15 20 25 30 35 40 45 50 Pounds Per Square Inch PSI SHPF 3 0 SHPF 3 0 3PH SHPF 2 0 SHPF 2 0 3PH SHPM 2 5 SHPF 1 5 SHPF 1...

Page 22: ...230 460 5 0 4 6 2 3 2 2 55 lbs 317 8 SHPF 1 5 3PH 1 5 208 230 460 6 4 5 8 2 9 2 2 57 lbs 321 8 SHPF 2 0 3PH 2 0 208 230 460 7 1 6 8 3 4 2 2 64 lbs 325 8 SHPF 3 0 3PH 3 0 208 230 460 9 0 8 6 4 3 2 3 6...

Page 23: ...HPF 1 5 B842 B2842 SHPF 2 0 B843 B2843 SHPF 3 0 B844 B2844 SHPF 1 0 3PH H635 SHPF 1 5 3PH H636 SHPF 2 0 3PH H637 SHPF 3 0 3PH H755 SHPF 1 0 2SPD B982 B2982 SHPF 1 5 2SPD B983 B2983 SHPF 2 0 2SPD B984...

Page 24: ...Commerce Way Vista CA 92081 1 800 822 7933 www ZodiacPoolSystems com ZODIAC is a registered trademark of Zodiac International S A S U used under license All trademarks referenced herein are the proper...

Reviews: