1.2 Pool Pump Suction Entrapment Prevention guidelines
SaVE tHESE inStruCtionS
Page 6
ENGLISH
Jandy
®
Pro Series Stealth
™
Pumps
|
Operation Manual
Warning
SuCtion HaZard. Can cause serious injury or death. do not use this pump for
wading pools, shallow pools or spas containing bottom drains, unless the pump is
connected to at least two (2) functioning suction outlets.
Warning
Pump suction is hazardous and can trap and drown or disembowel bathers. do not use or operate
swimming pools, spa, or hot tubs if a suction outlet cover is missing, broken, or loose.
The following
guidelines provide information for pump installation that minimizes the risk of injury to users of pools, spas, and
hot tubs:
Entrapment Protection
- The pump suction system must provide protection against the hazards of suction
entrapment.
Suction outlet Covers
- All suction outlets must have correctly installed, screw-fastened covers in place. All
suction outlet (drain) covers must be maintained. Drain covers must be listed/certified to the latest version of
ANSI/ASME A112.19.8. They must be replaced if cracked, broken, or missing.
number of Suction outlets Per Pump
- Provide at least two (2) hydraulically-balanced main drains, with
covers, as suction outlets for each circulating pump suction line. The centers of the main drains (suction outlets)
on any one (1) suction line must be at least three (3) feet apart, center to center. See Figure 1 on page 7.
The system
must
be built to include at least two (2) suction outlets (drains) connected to the pump whenever
the pump is running. However, if two (2) main drains run into a single suction line, the single suction line may be
equipped with a valve that will shut off both main drains from the pump. The system shall be constructed such
that it shall not allow for separate or independent shutoff or isolation of each drain. See Figure 1 on page 7.
More than one (1) pump can be connected to a single suction line as long as the requirements above are met.
Water Velocity
- The maximum water velocity through the suction fitting or cover for any suction outlet must be
1.5 feet per second unless the outlet complies with the latest version of ANSI/ASME A112.19.8, the standard for
Suction Fittings For Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs
. In any case, do not exceed the
suction fitting’s maximum designed flow rate.
If 100% of the pump’s flow comes from the main drain system, the maximum water velocity in the pump suction
hydraulic system must be 6 feet per second or less, even if one (1) main drain (suction outlet) is completely
blocked. The flow through the remaining main drain(s) must comply with the latest version of ANSI/ASME
A112.19.8, the standard for
Suction Fittings For Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs
.
testing and Certification
- Suction outlet covers must have been tested by a nationally recognized testing
laboratory and found to comply with the latest version of ANSI/ASME A112.19.8, the standard for
Suction Fittings
For Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs
.
Fittings
- Fittings restrict flow; for best efficiency use fewest possible fittings (but at least two (2) suction outlets).
Avoid fittings which could cause an air trap.
Pool cleaner suction fittings must conform to applicable International Association of Plumbing and Mechanical
Officials (IAPMO) standards.
Caution
The 3-phase SHPF series pumps utilize non-thermally protected motor assemblies. NRTL Listed Motor Controller
with internal motor running overload protection or external motor running overload are required during the final
installation of the pump assembly. Overloads shall be set at a maximum of 125% of the full-load current rating of
the pump motor assembly.