background image

Page 5 

ENGLISH

Jandy

®

 Pro Series Stealth

 Pumps   

|

   Operation Manual

 

Warning

To minimize the risk of severe injury or death the filter and/or pump should not be subjected to the pip-

ing system pressurization test.
Local codes may require the pool piping system to be subjected to a pressure test. These require-

ments are generally not intended to apply to the pool equipment such as filters or pumps.
Zodiac

®

 pool equipment is pressure tested at the factory.

However, if the WARNING cannot be followed and pressure testing of the piping system must include 

the filter and/or pump, BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS:

•  Check all clamps, bolts, lids, lock rings and system accessories to ensure they are properly installed 

and secured before testing.

•  RELEASE ALL AIR

 in the system before testing.

•  Water pressure for test must NOT EXCEED 35 PSI.
•  Water temperature for test must NOT EXCEED 100

°F (38°C).

•  Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.

notice

: These parameters apply to Zodiac equipment only. For non-Zodiac equipment, consult  equipment 

manufacturer.

Caution

do not start pump dry! 

Running the pump dry for any length of time will cause severe damage and will void the 

warranty.

 

Warning

Chemical spills and fumes can weaken pool/spa equipment. Corrosion can cause filters and other equipment to 

fail, resulting in severe injury or property damage. Do not store pool chemicals near your equipment. 

Caution

This pump is for use with permanently installed pools and may also be used with hot tubs and spas if so marked. 

Do not use with storable pools. A permanently installed pool is constructed in or on the ground or in a building 

such that it cannot be readily disassembled for storage. A storable pool is constructed so that it may be readily 

disassembled for storage and reassembled to its original integrity.

Caution

Do not install within an outdoor enclosure or beneath the skirt of a hot tub or portable spa. The pump requires 

adequate ventilation to maintain air temperature at less than the maximum ambient temperature rating listed on 

the motor rating plate. 

 

Warning

•  Do not connect the system to an unregulated city water system or other external source of pressurized water 

producing pressures greater than 35 PSI.

•  Trapped air in system can cause the filter lid to be blown off, which can result in death, serious personal injury, 

or property damage. Be sure all air is out of the system before operating.

Summary of Contents for Stealth Jandy Pro Series

Page 1: ...of the instructions in this manual can be followed exactly Before installing this product read and follow all warning notices and instructions that accompany this product Failure to follow warning not...

Page 2: ...Page 2 ENGLISH Jandy Pro Series Stealth Pumps Operation Manual...

Page 3: ...Routine Maintenance 13 5 2 Winterizing the Pump 13 Section 6 Troubleshooting and Repair 14 6 1 Troubleshooting 14 6 2 Service Technician Maintenance 15 Section 7 Product Specifications and Technical...

Page 4: ...rtified electrician or a qualified swimming pool service technician WARNING RISK OF ELECTRIC SHOCK FIRE PERSONAL INJURY OR DEATH Connect only to a branch circuit that is protected by a ground fault ci...

Page 5: ...ump dry Running the pump dry for any length of time will cause severe damage and will void the warranty WARNING Chemical spills and fumes can weaken pool spa equipment Corrosion can cause filters and...

Page 6: ...shall not allow for separate or independent shutoff or isolation of each drain See Figure 1 on page 7 More than one 1 pump can be connected to a single suction line as long as the requirements above a...

Page 7: ...al contact Zodiac Pool Systems Inc Zodiac at 800 822 7933 For address information see the back cover of this manual 2 2 Description SHP Pumps are designed to meet the needs of today s more hydraulical...

Page 8: ...on 1 Upon receipt of the pump check the carton for damage Open the carton and check the pump for concealed damage such as cracks dents or a bent base If damage is found contact the shipper or distribu...

Page 9: ...rom the pump 5 The piping must be well supported and not forced together where constant stress will be experienced 6 Always use properly sized valves Jandy Pro Series Diverter Valves and Ball Valves t...

Page 10: ...harp edges on terminals require extra protection To prevent wire nuts from loosening tape them using a suitable listed UL ETL CSA electrical insulating tape For safety and to prevent entry of contamin...

Page 11: ...elps to place the o ring on the step rather than to roll it on That prevents it from rolling off NOTE The blue o ring sits approximately away from the seal See Figure 4 4 Carefully install the lid mak...

Page 12: ...r Running the pump dry for any length of time can cause severe damage to both the pump and motor and will void the war ranty If this is a new pool installation make sure all piping is clear of constru...

Page 13: ...fy that all valves have been returned to the proper position for normal operation 9 Open the pressure release valve on the filter and make sure it is clean and ready for operation 10 Turn on the power...

Page 14: ...ion nuts to the pump With clean union o rings hand tightening of the unions should create a seal If the unions still do not seal gently tighten with a large pair of tongue and groove pliers Do not ove...

Page 15: ...ch off the circuit break ers at the power source Severe personal injury or death may occur if the pump starts while your hand is inside the pump 1 Turn off the pump Switch off the circuit breaker to t...

Page 16: ...new carbon face seal half see Figure 11 on the motor shaft using a twisting motion Make sure the carbon surface is facing toward the ceramic ring in the backplate CAUTION VERY IMPORTANT Grasp the low...

Page 17: ...screw is a left hand threaded screw Therefore turn the screw counter clockwise to tighten 3 Replace the motor shaft cover by inserting the cover tabs into the slots and rotating the cover 90 clockwis...

Page 18: ...hnician or electrician properly disconnect the electrical wiring at the pump motor 2 To disassemble the pump housing from the motor follow steps 1 through 8 in Section 6 2 2 Impeller Removal 3 Place t...

Page 19: ...1 Single speed Motor Hardware SHPF 3 Phase 1 0 R0479101 1 Single speed Motor Hardware SHPF 3 Phase 1 5 R0479102 1 Single speed Motor Hardware SHPF 3 Phase 2 0 R0479103 1 Single speed Motor Hardware SH...

Page 20: ...ing Seal All R0445800 9 Blue Pressure Test O ring All R0479000 10 Pump Debris Filter Basket All R0445900 11 Drain Plug w O ring Set of 2 All R0446000 12 Tail Piece 2 by 2 O ring Coupling Nut Set of 2...

Page 21: ...240 250 Flow Rate Gallons Per Minute GPM Total Dynamic Head FEET of H2O 0 5 10 15 20 25 30 35 40 45 50 Pounds Per Square Inch PSI SHPF 3 0 SHPF 3 0 3PH SHPF 2 0 SHPF 2 0 3PH SHPM 2 5 SHPF 1 5 SHPF 1...

Page 22: ...230 460 5 0 4 6 2 3 2 2 55 lbs 317 8 SHPF 1 5 3PH 1 5 208 230 460 6 4 5 8 2 9 2 2 57 lbs 321 8 SHPF 2 0 3PH 2 0 208 230 460 7 1 6 8 3 4 2 2 64 lbs 325 8 SHPF 3 0 3PH 3 0 208 230 460 9 0 8 6 4 3 2 3 6...

Page 23: ...HPF 1 5 B842 B2842 SHPF 2 0 B843 B2843 SHPF 3 0 B844 B2844 SHPF 1 0 3PH H635 SHPF 1 5 3PH H636 SHPF 2 0 3PH H637 SHPF 3 0 3PH H755 SHPF 1 0 2SPD B982 B2982 SHPF 1 5 2SPD B983 B2983 SHPF 2 0 2SPD B984...

Page 24: ...Commerce Way Vista CA 92081 1 800 822 7933 www ZodiacPoolSystems com ZODIAC is a registered trademark of Zodiac International S A S U used under license All trademarks referenced herein are the proper...

Reviews: