4. Disconnect all terminal bars and input/output
control signals from the power center PCB and
bezel assembly and remove it from the power
center can.
5. Make sure the new bezel assembly and the new
CPU board are fully assembled.
6. Re-connect the power center transformer 24 VAC
power plug to the 24 VAC 3-pin terminal on the
new power center PCB and bezel assembly and the
new CPU board.
7. Re-connect all terminal bars and input/output
control signals to the new power center PCB and
bezel assembly.
8. Reinstall the power center PCB and bezel assembly
in the power center can using the screws previously
removed.
Section 4. iAquaLink Network
Interface Installation
The iAquaLink J-box can be installed outdoors, on the
equipment pad, or inside your home with a choice of
wired or wireless connection.
The wireless iAquaLink J-box installation will transmit
through walls and around corners. Steel framing,
aluminum siding, wrought iron, cyclone fences, leaded
glass, and other 2.4 GHz frequency items may inhibit/
prevent communication between the iAquaLink J-Box
and the power center. The transceivers do not require
line of sight to communicate.
4.1
Outdoor Installation
WARNING
Potentially high voltages in the power center can
create dangerous electrical hazards, possibly
causing death, serious injury or property damage.
Turn off power at the main circuit feeding the power
center to disconnect the power center from the
system.
Never run high voltage and low voltage in the same
conduit.
1. Turn off all power to the power center.
iAquaLink
J-box
Minimum
8’ (2,4 m)
Air Blower
6’
(1,8 m)
Ground Level
Router
Computer
Internet Service
Provider
Wireless
or
Wired Connection
Low
Voltage
Area
Red 4-Pin
Terminal Bar
Internet
2. Mount the outdoor iAquaLink J-box at least six (6)
feet (1,8 m) above the ground, at least eight (8) feet
(2,4 m) from any motor or air blowers that may
be in the vicinity, and at least five (5) feet (1,5 m)
away from other transceiver J-boxes. See Figure 3.
NOTE
To improve performance of the transceiver,
mount the J-box more than six (6) feet (1,8 m)
above the ground.
3. Open the door to the power center and remove the
dead panel.
Figure 3.
iAquaLink J-Box Outdoor Installation
Page 8
iAquaLink™ Web Connect Device for AquaLink
®
RS and PDA Control Systems
|
Installation Manual
ENGLISH
Summary of Contents for iAquaLink