background image

ONETOUCH

 

Displays preset mood/scene settings.

HELP 

Displays the service and equipment 

information.

BACK 

Returns the user to the previous screen.

STATUS 

Displays information about the equipment.

5.1 

Dialog Boxes

These are secondary windows that provide additional 

information or alerts about an operation in progress.

CONFIRM 

Asks if the user wants to proceed with an 

action.

INFORMATION 

Informs the user of events that are related to 

the current user activity.

WARNING 

Alerts the user of a condition that might 

cause a problem.

ERROR 

Alerts the user of an error.

Section 5.  Web Interface Home 

Screen

This screen functions primarily as the log-on screen and 

starting point for each session, providing access to the 

main navigation bar. This screen displays the current 

time, date, temperature, and some user defined features.
As shown in the figure below, the iAquaLink menu 

screen displays the following layout:

 ▪ The title bar.
 ▪ The middle info panel.
 ▪ The navigation bar.

iAquaLink 

Home

Menu OneTouch

Help

Back

Status

FILTER

PUMP

SPA

POOL

HEAT

Pool Temp

86º

Air Temp

78º

SPA

HEAT

AUX1

AUX2

AUX3

Other

Devices

On/Off

Title Bar

Customize

Buttons

Navigation Bar

Devices

ON/OFF

Middle

Info Panel

Thu June 23, 2011  3:03 PM

5.9.1  Title Bar

The title bar displays the title of the screen and the 

current date/time. The title of the current menu in use 

will always be shown on the title bar. This portion of 

the screen is a read only bar and does not respond to 

commands. 

5.9.2  Middle Info Panel

The middle info panel on the HOME screen displays 

temperature, user defined features and access to the 

OTHER DEVICES ON/OFF screen.

5.9.3  Navigation Bar

The navigation bar displays the following links:

HOME 

Returns the user to HOME screen.

MENU 

Displays the main menu setup and 

programming.

Page 12

iAquaLink™ Web Connect Device for AquaLink

®

 RS and PDA Control Systems   

|

   Installation Manual

ENGLISH

  

 

Summary of Contents for iAquaLink

Page 1: ...ay not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to com...

Page 2: ......

Page 3: ...or Lights 11 4 7 Product Registration 11 4 8 iAquaLink Apps and Web Interface 11 4 8 1 Mobile Smart Device Apps 11 4 8 2 Web Browser Interface 11 Section 5 Web Interface Home Screen 12 5 9 1 Title Bar...

Page 4: ...are recommended for young children and when spa use exceeds 10 minutes b Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant...

Page 5: ...s or enclosures containing other conductors unless the additional conductors are also protected by a ground fault circuit interrupter Refer to local codes for complete details SAVE THESE INSTRUCTIONS...

Page 6: ...be updated to revision R or later The iAquaLink Web Connect Device can be used in addition to an existing PDA control system however the firmware in the power center must be updated to revision 6 0 o...

Page 7: ...Unscrew and remove the power center PCB and bezel assembly from the power center See Figure 2 4 Remove the CPU board from the power center PCB 5 For an RS system install the new CPU board revision R...

Page 8: ...iAquaLink J Box and the power center The transceivers do not require line of sight to communicate 4 1 Outdoor Installation WARNING Potentially high voltages in the power center can create dangerous e...

Page 9: ...ove the dead panel 5 Pull cable through the knockout with the Heyco or equivalent fitting and into the low voltage compartment See Figure 4 6 Strip back the insulation jacket of the cable approximatel...

Page 10: ...ection 4 4 To Set Up the J Box for Wired Connection 1 Remove the two 2 screws that secure the cover and gasket on the iAquaLink J box Remove the gasket and cover See Figure 5 2 Connect one end of the...

Page 11: ...o control the pool and spa features anytime anywhere Free iAquaLink smart device apps are available for devices such as Android iPhone iPad iPod Touch or any other HTML5 enabled device To download you...

Page 12: ...figure below the iAquaLink menu screen displays the following layout The title bar The middle info panel The navigation bar iAquaLink Home Menu OneTouch Help Back Status FILTER PUMP SPA POOL HEAT Pool...

Page 13: ...en 6 1 Menu Screen The MENU screen provides access to the main links to program set up schedule and customize your pool spa system 6 1 1 To Display the Menu Screen HOME MENU On the HOME screen click t...

Page 14: ...nly one piece of equipment can be selected at a time Second Step Programming the new device On the SCHEDULE screen the added equipment will be displayed and highlighted in the circuit list Also the ED...

Page 15: ...ge General Items Filter Pump VSP Pump Spa Pool Heat Spa Heat Label One Label Two Label Three Label Four Label Five Label Six Label Seven Thu June 23 2011 3 03 PM Home Menu OneTouch Help Back Status Cu...

Page 16: ...connection screen is displayed but override switches at the power center do not operate at all 1 Damaged or improperly installed CPU board 2 Wrong CPU board 3 Damaged power center PCB 1 Check alignme...