background image

Never run high voltage and low voltage in the same 
conduit.

 

1.  Turn off all power to the power center.
2.  Find a suitable place inside your home to mount the  

iAquaLink 2.0 device.

3.  Install the  iAquaLink 2.0 device at least six (6) feet  

(1.8 m) above the ground and at least five (5) feet  

(1.5 m) away from other transceiver J-boxes.

NOTE 

To improve performance of the iAquaLink 

2.0 device, you may wait to permanently 

mount it after it has been powered up. The 

signal strength indicator shown during the 

WiFi Hotspot method is a convenient way to 

determine & optimize signal strength between 

the iAquaLink device and the router.

4.  Open the door to the power center and remove the 

dead panel.

5.  Pull cable through the knockout and into the low 

voltage area. See Figure 4. 

6.  Strip back the insulation jacket of the cable 

approximately 6" (15 cm).

7.  Strip each wire ¼" (6 mm) and connect to the 

red, wire connector on the power center PCB. A 

multiplex kit (P/N 6584) may be required if there 

are more than two (2) cables running to a red, wire 

connector on the power center PCB.

4.3 

Set Up the  iAquaLink 2.0 Device for 

Wireless Connection

There are 2 ways to do this, the Hotspot Method and the 

WPS Method. 
For wired connection skip to Section 4.5

Connect iAquaLink to the Home Network - 

WiFi Hotspot Method

1.  Remove the two (2) screws from the cover of the  

iAquaLink 2.0 J-box. Remove the gasket and cover. 

See Figure 5.

2.  Inside the iAquaLink 2.0, toggle the WiFi - Wired 

switch to clear the Wi-Fi settings and put the 

iAquaLink in desired setup mode. 

3.  After clearing the WiFi settings and with the Wired/

WiFi switch set to WiFi, use a smartphone or WiFi 

enabled device and go to WiFi settings. Connect 

to the network labeled iAquaLink, followed by the 

last three digits of the iAquaLink device number.  

For example, iAquaLink ABC, if the last 3 digits of 

the device were ABC.

4.  Locate the device number on the side product label 

or the door hanger that came with the device

5.  Some devices will automatically re-direct you to 

the Log In Screen. If not, open a browser and go to 

any web page, such as zodiacpoolsystems.com

6.  iAquaLink will display the networks it detects, 

as well as signal strength. Select the network 

iAquaLink should use.

NOTE 

If prompted for a password, enter the password 

for the home network (caps sensitive). 

iAquaLink will disconnect from the smartphone 

at this point.

7.  Within 2 minutes, the yellow LED should turn 

solid yellow, indicating it is communicating with 

the router. When the green LED illuminates, the 

iAquaLink is connected.

Connect iAquaLink to the Home Network - 

WPS (WiFi Protected Setup) Method

1.  Remove the two (2) screws from the cover of the  

iAquaLink 2.0 J-box. Remove the gasket and cover. 

See Figure 5.

2.  Push the WPS Button on the pool owner’s router. 

To find it, look for the   symbol or see the 

following notes.

Figure 4. 

 iAquaLink 2.0 J-Box Indoor Installation

Internet Service

Provider

iAquaLink 2.0

Device

Router

Computer

Wireless 

or 

Wired Connection

Red 4-Pin

Terminal Bar

Low

Voltage

Area

Internet

Page 9

iAquaLink™ 

2.0

 Web Connect Device for AquaLink

®

 Control Systems   

|

   Installation Manual

ENGLISH

  

 

Summary of Contents for iAquaLink 2.0

Page 1: ...onditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has bee...

Page 2: ......

Page 3: ...AquaLink 2 0 Device on the web 10 4 6 LED Status Indicator Lights 10 4 7 Account and Location Setup 11 4 8 iAquaLink Apps and Web Interface 11 Section 5 Web Interface Home Screen 11 5 1 Title Bar 12 5...

Page 4: ...inutes b Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibly pregnant women should consult a physician before us...

Page 5: ...vided if this device is used to control underwater lighting fixtures The conductors on the load side of the ground fault circuit interrupter shall not occupy conduit boxes or enclosures containing oth...

Page 6: ...ep is for the AquaLink RS with revision N firmware or newer ONLY For AquaLink PDA systems please go to section 3 2 WARNING Potentially high voltages in the power center can create dangerous electrical...

Page 7: ...3 Unplug the power center transformer 24 VAC power plug from the 24 VAC 3 pin terminal on the power center PCB and bezel assembly as shown in Figure 2 4 Disconnect all terminal bars and input output c...

Page 8: ...ket of the cable approximately 6 15 cm 6 Strip each wire 6 mm and connect to the red wire connector on the power center PCB A multiplex kit P N 6584 may be required if there are more than two 2 cables...

Page 9: ...clear the Wi Fi settings and put the iAquaLink in desired setup mode 3 After clearing the WiFi settings and with the Wired WiFi switch set to WiFi use a smartphone or WiFi enabled device and go to Wi...

Page 10: ...ce Wrap the cable inside the J box and route it through the break away hole 4 Using an Ethernet RJ45 cable connect the iAquaLink 2 0 device to the homeowner s router 5 Reinstall the cover and gasket o...

Page 11: ...S systems only Using any computer or mobile device the iAquaLink web interface may be used to program configure control every device and feature available in the AquaLink RS system How to Access the W...

Page 12: ...e current date time The title of the current menu in use will always be shown on the title bar This portion of the screen does not respond to commands 5 2 Middle Info Panel The middle info panel on th...

Page 13: ...PM Set Date Time Time 00 00 PM Click ENTER when finished 6 3 Scheduling and Adding Devices CAUTION Make sure DATE and TIME are set up correctly before programming and scheduling any devices The SCHEDU...

Page 14: ...Other Devices On Off Thu June 23 2011 3 03 PM MENU CUSTOMIZE HOME 1 Select label group 2 Select label name from list 3 Touch icon to assign General Aux OneTouch Page Page General Items Filter Pump VS...

Page 15: ...board is revision 6 0 or later for PDA control system 3 If CPU board is installed correctly replace the power center PCB Some buttons do not operate from the iAquaLink 2 0 nor from the power center ov...

Page 16: ...s 2013 Zodiac Pool Systems Inc H0435500 Rev B Zodiac Pool Systems Canada Inc 2115 South Service Road West Unit 3 Oakville ON L6L 5W2 1 888 647 4004 www ZodiacPoolSystems ca Zodiac Pool Systems Inc 262...

Reviews: