background image

ON/OFF Times

MENU > SCHEDULE > EDIT > START TIME

Thu June 23, 2011  3:03 PM

Schedule

Home

Menu OneTouch

Help

Back

Status

Circuit 

Start Time  Stop Time 

Days

VSP 

7:00 AM 

6:00 PM 

Th, Wknd

Pool 

8:00 AM 

5:00 PM 

All

Spa 

7:00 PM 

10:00 PM 

F, Sa

Spa 

5:00 PM 

9:00 PM 

M, W

Spa Heat 

6:00 PM 

8:00 PM 

All

Pool Light 

6:00 PM 

8:00 PM 

All 

Page

Down

Page

Up

  Add 

Edit 

Delete

  Save 

Run Days

Start Time

Stop Time

 All 

Tu 

W

 Th 

Sa 

Su

 Week Days 

Weekends

Enter the desired START TIME. Toggle the AM/PM 

button to select your choice. Do the same for the STOP 

TIME. When finished setting all schedules press SAVE 

to store.

  7  8  9
  4  5  6
  1  2  3
  0 

  Clear  Enter

01:00

 

PM

6.4 

Customize Home

The CUSTOMIZE HOME screen is used to change the 

first seven (7) equipment icons on the HOME screen.

iAquaLink 

Home

Menu OneTouch

Help

Back

Status

FILTER

PUMP

SPA

POOL

HEAT

Pool Temp

86º

Air Temp

78º

SPA

HEAT

AUX1

AUX2

AUX3

Other

Devices

On/Off

Thu June 23, 2011  3:03 PM

MENU > CUSTOMIZE HOME

1) Select label group
2) Select label name 

from list 

3) Touch icon to assign

General

Aux

OneTouch

Page

Page

General Items
Filter Pump
VSP Pump 
Spa 
Pool Heat
Spa Heat

Label

One

Label

Two

Label

Three

Label

Four

Label

Five

Label

Six

Label

Seven

Thu June 23, 2011  3:03 PM

Home

Menu OneTouch

Help

Back

Status

Customize Home

6.5 

Customize General, Aux and 

OneTouch™ Items

Highlight the GENERAL, AUX or ONETOUCH 

button. Select the desired item from the item list. 
Click an icon from the bottom list. The label of the icon 

should reflect the assigned item. 
Use the UP/DOWN arrows to scroll the list.

1) Select label group
2) Select label name 

from list 

3) Touch icon to assign 

General

Aux

OneTouch

Page

Page

General Items
Filter Pump
VSP Pump 
Spa 
Pool Heat
Spa Heat

Label

One

Label

Two

Label

Three

Label

Four

VSP
Pump

Label

Six

Label

Seven

Thu June 23, 2011  3:03 PM

Home

Menu OneTouch

Help

Back

Status

Customize Home

 

Page 14

iAquaLink™ 

2.0

 Web Connect Device for AquaLink

®

 Control Systems   

|

   Installation Manual

ENGLISH

  

 

Summary of Contents for iAquaLink 2.0

Page 1: ...onditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has bee...

Page 2: ......

Page 3: ...AquaLink 2 0 Device on the web 10 4 6 LED Status Indicator Lights 10 4 7 Account and Location Setup 11 4 8 iAquaLink Apps and Web Interface 11 Section 5 Web Interface Home Screen 11 5 1 Title Bar 12 5...

Page 4: ...inutes b Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibly pregnant women should consult a physician before us...

Page 5: ...vided if this device is used to control underwater lighting fixtures The conductors on the load side of the ground fault circuit interrupter shall not occupy conduit boxes or enclosures containing oth...

Page 6: ...ep is for the AquaLink RS with revision N firmware or newer ONLY For AquaLink PDA systems please go to section 3 2 WARNING Potentially high voltages in the power center can create dangerous electrical...

Page 7: ...3 Unplug the power center transformer 24 VAC power plug from the 24 VAC 3 pin terminal on the power center PCB and bezel assembly as shown in Figure 2 4 Disconnect all terminal bars and input output c...

Page 8: ...ket of the cable approximately 6 15 cm 6 Strip each wire 6 mm and connect to the red wire connector on the power center PCB A multiplex kit P N 6584 may be required if there are more than two 2 cables...

Page 9: ...clear the Wi Fi settings and put the iAquaLink in desired setup mode 3 After clearing the WiFi settings and with the Wired WiFi switch set to WiFi use a smartphone or WiFi enabled device and go to Wi...

Page 10: ...ce Wrap the cable inside the J box and route it through the break away hole 4 Using an Ethernet RJ45 cable connect the iAquaLink 2 0 device to the homeowner s router 5 Reinstall the cover and gasket o...

Page 11: ...S systems only Using any computer or mobile device the iAquaLink web interface may be used to program configure control every device and feature available in the AquaLink RS system How to Access the W...

Page 12: ...e current date time The title of the current menu in use will always be shown on the title bar This portion of the screen does not respond to commands 5 2 Middle Info Panel The middle info panel on th...

Page 13: ...PM Set Date Time Time 00 00 PM Click ENTER when finished 6 3 Scheduling and Adding Devices CAUTION Make sure DATE and TIME are set up correctly before programming and scheduling any devices The SCHEDU...

Page 14: ...Other Devices On Off Thu June 23 2011 3 03 PM MENU CUSTOMIZE HOME 1 Select label group 2 Select label name from list 3 Touch icon to assign General Aux OneTouch Page Page General Items Filter Pump VS...

Page 15: ...board is revision 6 0 or later for PDA control system 3 If CPU board is installed correctly replace the power center PCB Some buttons do not operate from the iAquaLink 2 0 nor from the power center ov...

Page 16: ...s 2013 Zodiac Pool Systems Inc H0435500 Rev B Zodiac Pool Systems Canada Inc 2115 South Service Road West Unit 3 Oakville ON L6L 5W2 1 888 647 4004 www ZodiacPoolSystems ca Zodiac Pool Systems Inc 262...

Reviews: