EQUIPMENT INFORMATION RECORD

DATE OF INSTALLATION 

 ....................................................................................................................................

INSTALLER INFORMATION

 ................................................................................................................................

......................................................................................................................................................................................................

INITIAL PRESSURE GAUGE READING (WITH CLEAN FILTER)

 .........................................

(IF APPLICABLE)

PUMP MODEL

.........................................................................

 KILOWATT

............................................................

NOTES

 ....................................................................................................................................................................................

......................................................................................................................................................................................................

......................................................................................................................................................................................................

Section 1. Important Safety Instructions

READ AND FOLLOW ALL INSTRUCTIONS

1.1 Safety Instructions

All electrical work must be performed by a licensed electrician and conform to all national, 

state, and local codes. When installing and using this electrical equipment, basic safety 

precautions should always be followed, including the following:

RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED, CAN 

RESULT IN SERIOUS INJURY AND/OR DEATH. 

Do not block pump suction, as this can cause severe injury and/or death.

To reduce the risk of injury, do not permit children to use this product.

To reduce the risk of property damage and/or injury, do not attempt to change 

the backwash multiport valve position with the pump running.

The  Pump  is  for  fixed  installations  only  and  to  be  used  in  conjunction  with 

swimming pool equipment. (E.g. filters). The pump is to be installed in accordance 

with the relevant requirements of the South African wiring rules. Occupational 

Health and Safety Act, 1993 (Act no. 85 of 1993) schedule electrical installation 

regulations

Also refer to the installation instructions relating to the swimming pool equipment 

of which the pump will be an integral part. 

The  pump  is  to  be  supplied  through  a  circuit  breaker  with  a  related  residual 

operating current of 30mA.                                                                                                

Chemical spills and fumes can weaken pool/spa equipment. Corrosion can cause 

filters and other equipment to fail, resulting in severe personal injury or property 

damage. Do not store pool chemicals near your equipment. 

CAUTION: Do not start pump dry!

 Running the pump dry will cause severe damage and 

will void the warranty.

CAUTION: 

This pump is for use with permanently installed pools and may also be used 

with spas. Do not use with storable pools. A permanently installed pool is constructed in 

or on the ground or in a building such that it cannot be readily disassembled for storage. 

A storable pool is constructed so that it may be readily disassembled for storage and 

reassembled to its original integrity. 

SAVE THESE INSTRUCTIONS

Summary of Contents for FLOPRO SS

Page 1: ...Installation and Operation Manual ...

Page 2: ...onal injury or death Improper installation and or operation will void the warranty ATTENTION INSTALLER This manual contains important information about the installation operation and safe use of this product This information should be given to the owner operator of this equipment Contents Section 1 Important Safety Instructions 1 1 Safety Instructions 1 2 Pool Pump Suction Entrapment Prevention Gu...

Page 3: ...th swimming pool equipment E g filters The pump is to be installed in accordance with the relevant requirements of the South African wiring rules Occupational Health and Safety Act 1993 Act no 85 of 1993 schedule electrical installation regulations Also refer to the installation instructions relating to the swimming pool equipment of which the pump will be an integral part The pump is to be suppli...

Page 4: ...ing will be achieved if the pump is installed as close as possible to the water level of the pool 2 Zodiac Pool Care SA Pty Ltd recommends that the pump and other circulation equipment be located more than 1 5 metres from the water Choose a location that will minimize turns in the piping 3 The pump must be placed on a solid foundation that will not vibrate To further reduce the possibility of vibr...

Page 5: ...y length of time will cause severe damage to both the pump and motor and will void the warranty If this is a new pool installation make sure all piping is clear of construction debris Check the filter for proper installation verifying that all connections and clamps are secure according to the manufacturer s recommendations To avoid risk of property damage severe personal injury or death verify th...

Page 6: ...immer baskets pump basket and other screens are clean Clean as necessary Check filter and clean as necessary Check valve positions Adjust as necessary NOTE Multiple pieces of equipment operating at one time for example waterfalls spa jets and surface returns may affect the cleaning system and prevent it from working properly Check the cleaning system manual to ensure that the system is adjusted ac...

Page 7: ...ter from reaching the pump Drain the water from the pump by loosening the unions or removing the drain plugs 3 Using a 14mm wrench loosen the bolts connecting the pump body to the motor backplate See Figure 1 Figure 1 Remove the Pump body 4 Pull the motor and backplate out of the pump body Remove the pump body o ring The impeller is connected to the motor shaft 5 Using a No 1 Phillips star screwdr...

Page 8: ... the carbon face seal half from the impeller sleeve See Figure 5 This is a spring loaded seal Grasp the portion of the seal closest to the impeller body and pull the seal off using a twisting motion Ceramic Face Seal Backplate Seal Figure 5a Mechanical Seal CAUTION VERY IMPORTANT Grasp the lower portion of the seal opposite the carbon face when installing the seal or it will be damaged NOTE To ass...

Page 9: ...peration Zodiac requires that you replace the motor with a motor that has the identical kW rating and service factor To avoid the risk of property damage severe personal injury or death turn off the pump and switch off the circuit breaker to the pump motor before beginning this procedure 1 To disassemble the pump housing from the motor follow steps 1 through 8 in Section 6 2 2 Impeller Removal 2 R...

Page 10: ...ac FLOPRO Single Speed Pump Specs 0 6kW 0 75kW 1 1kW Model FLOPRO 0 6kW FLOPRO 0 75kW FLOPRO 1 1kW Motor Type Single Phase Single Phase Single Phase Pump kW 0 6kW 0 75HP 0 75kW 1 0HP 1 1kW 1 5HP Motor kW 0 8kW 1 0kW 1 4kW Motor Voltage Alternating Current and Frequency Hertz V230 AC Hz50 V230 AC Hz50 V230 AC Hz50 Motor Amps Maximum Amax 3 6A 4 6A 6 2A Motor Revolutions Per Minute RPM 2820 2820 282...

Page 11: ...ZODIAC CUSTOMER CARE CENTRE Zodiac Group South Africa Customer care line 0860 887 665 Email customer care zodiac com www zodiac co za ...

Reviews: