2.2 I Installing the temperature sensor (depending on the model)
•
The water temperature sensor displays the water temperature value on the appliance screen and manages
chlorinati on according to the temperature. The sensor must measure the temperature of the water
upstream of any possible heati ng system.
•
The sensor is designed to be mounted on rigid Ø50 mm, Ø63 mm or Ø1 ½’’ PVC pipes. Do not install on any
other type of pipe.
•
Install the sensor either between the fi lter pump and the fi lter, or between the fi lter and any other
downstream equipment, see
“2.1 I Installing the cell”:
-
Drill a hole in the pipe using a Ø9 mm (max. Ø10 mm) drill bit, then deburr the hole,
-
Install the O-ring provided on the sensor body,
-
Secure the sensor using the stainless-steel clamping collar provided. Do not use excess strength.
: Sensor
:
O-ring
:
Stainless steel clamping
collar
2.3 I Installing the fl ow switch
(chlorinator only without pH Link or Dual Link modules)
In cases where a pH Link or Dual Link module is used, the fl ow switch will be installed on the POD
Kit, see
“3.3 I Installing the fl ow switch on the POD kit”
•
The fl ow switch and its 50 mm diameter fi xture collar supplied as standard (63 mm diameter available
as a spare part) must be installed immediately before the cell and aft er any valves present
(
).
Use the
threaded adapter and the Tefl on tape provided to install the fl ow switch on its fi xture collar.
•
Screw the fl ow switch using using the clamping nut only (screw by hand!)
(
).
Clamping
nut
Directi on of water
fl ow
Installati on on a by-pass
In-line installati on
• Failure to comply with these instructi ons could lead to the destructi on of the cell! The
manufacturer cannot be held liable in this case.
• The fl ow switch has a directi on for installati on (arrow indicated on it showing the fl ow
directi on for the water). Make sure that it is correctly placed on its fi xture collar so that it
stops the appliance's producti on when fi ltering is stopped.