Page 13
The controller will remain in this state until the
contact is opened. When more than one contact closure
occurs, the highest speed will take priority.
NOTE
When starting the pump via a remote closure,
the pump will first run at the priming speed for
the priming duration, as set by the installer.
4.6.1 Remote Closure 4 Behavior
The behavior of speed 4 differs from other
speeds when operated via a remote contact closure.
As during manual operation, the turn-on time of
remote closure 4 is immediate, and occurs at the same
time as the contact closure. The turn-off time, however,
is delayed by 30 minutes. In other words, when remote
closure 4 is de-activated, the pump will continue to run
for 30 minutes, after which time the controller will turn
off the pump. The delay may be manually interrupted by
pressing any preset key.
4.6.2 Remote Closure 4 Application -
Booster Pump Support
The behavior of remote closure 4 may be
used to allow an external timeclock fitted with a
20-minute electrical isolation switch (e.g., Intermatic
P/N 156T4042A) to properly control the pump in
conjunction with a booster pump. Consult your installer
for further information.
4.7
Pump Freeze Protect
To help protect against pump damage, the
controller monitors the temperature inside the pump.
If enabled, pump freeze protect will start the pump
at the eStar speed when the temperature approaches
freezing. The pump will then run for a duration set by
the installer.
IMPORTANT INFORMATION
ON FREEZE PROTECTION
Freeze protection is intended to protect equipment and
plumbing for short periods of freezing only. It does this
by activating the filtration pump and circulating the water
to prevent freeze inside equipment or plumbing. Freeze
protection does not guarantee that equipment will not be
damaged by extended periods of freezing temperatures
or power outages. In these conditions, the pool and spa
should be shut down completely (e.g. drained of water and
closed for the winter) until warmer weather exists.
The pump freeze protect run time may be
interrupted by pressing a preset key, as follows:
Pressing the "
" key once overrides the pump
freeze protect run time, pressing it twice turns off the
pump. Pressing other preset keys will override the pump
freeze protect run time and activate the selected preset
speed.
4.8
Keypad Lock
Press and hold both arrow keys for five (5)
seconds to lock the keypad. To disable the keypad lock,
repeat the procedure while the keypad is locked.