background image

Page 11

4.3.2  Speeds 5 through 8

To start the pump manually at speeds "5" 

through "8", press the 

MENU

 button. The controller 

displays 

SELECT PRESET/N:LABEL

, where n:label 

is the number and label of the last selected preset "5" 
through "8".

Using the arrow keys, select the desired preset 

to activate, and then press 

MENU

 to enter 

RUN 

mode, 

starting the pump running at the selected speed. 

2

3

4

SELECT PRESET
                            5:PRESET 5

ePUMP

MENU

To stop the pump, press 

MENU

. To exit without 

starting the pump, press any button "

" through "4".

4.4 

Pump Speed Setting

With the exception of preset "

", the pump 

speed for each preset may be adjusted while the pump is 
running in that preset mode. Preset "

" is reserved for 

the eStar function, and its speed is set by the installer.

To adjust the pump speed, the controller must 

be in the 

RUN

 mode. While in 

RUN

 mode, the controller 

displays the pump speed. Adjust the speed by pressing 
the up or down arrow keys. The speed is saved by the 
controller and will remain until changed again.

NOTE

  Pump speed is adjustable only within a certain 

range. The minimum and maximum limits of the 
range are set by the installer.

4.5 

Timeclock Setup and Operation

The controller allows the user to create timed 

pump programs on pump speeds (presets) "

and "2". The two timers operate independently of each 
other, and may overlap in time if desired.

4.5.1  Timeclock Setup

Start the desired speed, "

" or "2". Press 

MENU

. The controller enters the Timeclock setup mode. 

Using the arrow keys, select 

ON TIME

 and press 

MENU

Set the desired pump turn-on time using the arrow keys 
and press 

MENU

. The time is stored. Select 

OFF TIME

 

using the arrow keys and press 

MENU

. Set the desired 

pump turn-off time using the arrow keys and press 

MENU

. The time is stored. 

NOTE

  If your filtration equipment run time is controlled 

via an external timeclock such as a chlorinator 
or a solar controller, add filtration run time to the 
default 

12:00AM

 (midnight) 

ON TIME

 

Example: 
Should you wish to run filtration for 8 hours per 
day set the 

ON TIME

 as 

12:00AM

 (midnight) 

and set the ePump 

OFF TIME

 as 

8:00AM

 

Please note this does not mean the filtration will 
operate at midnight. It indicates the epump will 
run for 8 hours duration from when it receives 
power from the external timeclock.

Summary of Contents for ePump

Page 1: ...t must be installed and serviced by a professional pool spa service technician The procedures in this manual must be followed exactly Failure to follow warning notices and instructions may result in p...

Page 2: ......

Page 3: ...r 9 3 1 The ePump Controller 9 3 2 The ePump Controller Interface 9 3 3 Basic Functions 10 Section 4 User Operation 10 4 1 OFF Mode 10 4 2 RUN Mode 10 4 3 Manual Start and Stop 10 4 4 Pump Speed Setti...

Page 4: ...en or missing Never replace a suction fitting with one rated less than the flow rate marked on the equipment assembly WARNING To Reduce the Risk of Injury a The water in a spa should never exceed 40 C...

Page 5: ...mometer Do not use a spa or hot tub immediately following strenuous exercise Prolonged immersion in a spa or hot tub may be injurious to your health Do not permit any electric appliance such as a ligh...

Page 6: ...r Components The ePump controller assembly See Figure 2 contains the following components 1 ePump Controller 2 Mounting Gasket 3 Backplate 4 Round Seal 5 Six 6 Screws Additional materials are required...

Page 7: ...igure 2 5 Mark the hole locations on the wall and use the fastener to secure the backplate to the wall 6 At the bottom of the backplate cut the two 2 tabs out with an appropriate tool such as a Stanle...

Page 8: ...n on all switches and the main breaker feeding power to the ePump 5 Verify the operation of the contact closures If the correct speed is activated when the closure is activated the ePump starts and th...

Page 9: ...in breaker feeding power to the ePump 8 If the installation is working properly the fireman s switch will open 20 minutes before the booster pump shuts down the ePump will continue to run for 30 minut...

Page 10: ...time of day clock 4 2 RUN Mode When the pump is running not off the controller displays n label 00 00 RPM xxxx where n label is the number and label of the selected preset 00 00 is the time of day clo...

Page 11: ...e only within a certain range The minimum and maximum limits of the range are set by the installer 4 5 Timeclock Setup and Operation The controller allows the user to create timed pump programs on pum...

Page 12: ...hen starting the pump via a timed program the pump will first run at the priming speed for the priming duration as set by the installer If a program overlap occurs the pump will immediately start at t...

Page 13: ...ller for further information 4 7 Pump Freeze Protect To help protect against pump damage the controller monitors the temperature inside the pump If enabled pump freeze protect will start the pump at t...

Page 14: ...Minimum and maximum pump speeds eStar speed Pump Freeze Protect operation 5 1 Entering Service Setup NOTE The ePump controller must be in the OFF mode all LED s lights must be off before entering the...

Page 15: ...To clear the fault history press either arrow key 5 5 Priming Speed and Duration The ePump controller will command the ePump to operate at the priming speed for the priming duration specified except d...

Page 16: ...protect equipment and plumbing for short periods of freezing only It does this by activating the filtration pump and circulating the water to prevent freeze inside equipment or plumbing Freeze protec...

Page 17: ...SET Press the MENU button to display the currently selected preset Using the arrow keys choose the preset to be changed Press MENU to select The controller displays SELECT LABEL TYPE Select GENERAL or...

Page 18: ...election From the setup menu select LANGUAGE using the arrow keys Press MENU Using the arrow keys select the desired language Press MENU to save the selection 6 7 Run Duration Presets 3 and 4 Only Pre...

Page 19: ...Page 19 Section 7 Menu Flow Chart...

Page 20: ...H0352000 Zodiac Group Australia Pty Ltd 219 Woodpark Road Smithfield NSW 2164 Ph 1800 688 552 Fax 02 9756 3987...

Reviews: