Page 15
Default Speeds
eStar
1750 RPM
Preset 2 - 8
2750 RPM
Priming Speed
2750 RPM
Other Defaults
Freeze Protect Duration
30 min
Priming Duration
1 min
5.4
Last Fault
This feature shows on the top display line, the
most recent unique fault message and on the bottom
display line, the second-to-last unique fault message.
If there is no entry for a fault, the display will show
“*----------------*” on the corresponding line. To select
last fault, from the service setup menu select
LAST
FAULT
. Press
MENU
.
NOTE The fault messages are stored in non-volatile
memory, and remain even with no power. To
clear the fault history, press either arrow key.
5.5
Priming Speed and Duration
The ePump™ controller will command the
ePump™ to operate at the priming speed for the
priming duration specified (except during timer program
overlaps or follow-on commands where the pump is
not stopped before changing speeds). From the service
setup menu, select
PRIMING
using the arrow keys.
Press
MENU
.
To set priming speed, select
PRIMING SPEED
using the arrow keys. Press
MENU
. Using the arrow
keys, set the priming speed to the desired value. Press
MENU
to accept and store.
To set priming duration, select
PRIMING
DURATION
using the arrow keys. Press
MENU
. Using
the arrow keys, set the priming speed to the desired
value in minutes from one (1) to five (5) minutes. Press
MENU
to accept and store.