background image

Page 12

Using the arrow keys, select 

TIMECLOCK

Select 

ENABLE

 using the arrow keys. The program is 

now enabled to run. Press the preset button ("

" or 

"2") to return to the 

RUN

 mode.

4.5.2  Timeclock Operation

When the pump is stopped, the associated green 

LED will illuminate, indicating a timeclock program is 
enabled for that speed.

If two (2) timed programs overlap, the program 

with the faster speed will take priority and run to 
completion. If the earlier-starting program is still 
active, it will resume operation. The program off times 
never change, i.e., they are not ‘pushed-out’ in time 
when programs overlap. Timeclock programs may be 
prematurely stopped by stopping the pump manually 
from the keypad. This override is active until the 
program start time is reached again, at which time the 
timed program will start the pump as programmed. See 
Section 3.5.3, Manually Overriding a Timer Program.

If the pump is started manually at a speed that 

has been programmed with a timer, the pump will be 
stopped by the timeclock at the programmed off time. 
See Section 3.5.4, Timer Overriding a Manual On.

NOTE

  When starting the pump via a timed program, 

the pump will first run at the priming speed for 
the priming duration, as set by the installer. 
If a program overlap occurs, the pump will 
immediately start at the program speed without 
priming first.

4.5.3  Manually Overriding a Timer 

Program

Timeclock programs may be prematurely 

stopped by pressing the active preset key. This override 
is active until the program start time is reached again, 
i.e., for 24 hours, at which time the timed program will 
start the pump as programmed.

4.5.4  Timer Overriding a Manual On

If the pump is started manually at a speed that 

has been programmed with a timer, the pump will be 
stopped by the timeclock at the programmed off time. 
A clock icon appears on the display when the timer has 
assumed control of the off time.

4.6 

Remote Operation

The controller allows speeds "

", "2", and "3" 

to be operated like manually operated speeds via remote 
contact closures. Speed "4" may also be operated 
remotely, but it behaves differently. See Section 2.10, 
Remote Closure 4 Behavior.

Speeds activated via remote closures always 

override speeds that have been activated manually or via 
an internal timer program. When the pump is activated 
via a remote closure, the keypad is disabled and the 
message 

REMOTE ENABLED

 appears on the display. 

Summary of Contents for ePump

Page 1: ...t must be installed and serviced by a professional pool spa service technician The procedures in this manual must be followed exactly Failure to follow warning notices and instructions may result in p...

Page 2: ......

Page 3: ...r 9 3 1 The ePump Controller 9 3 2 The ePump Controller Interface 9 3 3 Basic Functions 10 Section 4 User Operation 10 4 1 OFF Mode 10 4 2 RUN Mode 10 4 3 Manual Start and Stop 10 4 4 Pump Speed Setti...

Page 4: ...en or missing Never replace a suction fitting with one rated less than the flow rate marked on the equipment assembly WARNING To Reduce the Risk of Injury a The water in a spa should never exceed 40 C...

Page 5: ...mometer Do not use a spa or hot tub immediately following strenuous exercise Prolonged immersion in a spa or hot tub may be injurious to your health Do not permit any electric appliance such as a ligh...

Page 6: ...r Components The ePump controller assembly See Figure 2 contains the following components 1 ePump Controller 2 Mounting Gasket 3 Backplate 4 Round Seal 5 Six 6 Screws Additional materials are required...

Page 7: ...igure 2 5 Mark the hole locations on the wall and use the fastener to secure the backplate to the wall 6 At the bottom of the backplate cut the two 2 tabs out with an appropriate tool such as a Stanle...

Page 8: ...n on all switches and the main breaker feeding power to the ePump 5 Verify the operation of the contact closures If the correct speed is activated when the closure is activated the ePump starts and th...

Page 9: ...in breaker feeding power to the ePump 8 If the installation is working properly the fireman s switch will open 20 minutes before the booster pump shuts down the ePump will continue to run for 30 minut...

Page 10: ...time of day clock 4 2 RUN Mode When the pump is running not off the controller displays n label 00 00 RPM xxxx where n label is the number and label of the selected preset 00 00 is the time of day clo...

Page 11: ...e only within a certain range The minimum and maximum limits of the range are set by the installer 4 5 Timeclock Setup and Operation The controller allows the user to create timed pump programs on pum...

Page 12: ...hen starting the pump via a timed program the pump will first run at the priming speed for the priming duration as set by the installer If a program overlap occurs the pump will immediately start at t...

Page 13: ...ller for further information 4 7 Pump Freeze Protect To help protect against pump damage the controller monitors the temperature inside the pump If enabled pump freeze protect will start the pump at t...

Page 14: ...Minimum and maximum pump speeds eStar speed Pump Freeze Protect operation 5 1 Entering Service Setup NOTE The ePump controller must be in the OFF mode all LED s lights must be off before entering the...

Page 15: ...To clear the fault history press either arrow key 5 5 Priming Speed and Duration The ePump controller will command the ePump to operate at the priming speed for the priming duration specified except d...

Page 16: ...protect equipment and plumbing for short periods of freezing only It does this by activating the filtration pump and circulating the water to prevent freeze inside equipment or plumbing Freeze protec...

Page 17: ...SET Press the MENU button to display the currently selected preset Using the arrow keys choose the preset to be changed Press MENU to select The controller displays SELECT LABEL TYPE Select GENERAL or...

Page 18: ...election From the setup menu select LANGUAGE using the arrow keys Press MENU Using the arrow keys select the desired language Press MENU to save the selection 6 7 Run Duration Presets 3 and 4 Only Pre...

Page 19: ...Page 19 Section 7 Menu Flow Chart...

Page 20: ...H0352000 Zodiac Group Australia Pty Ltd 219 Woodpark Road Smithfield NSW 2164 Ph 1800 688 552 Fax 02 9756 3987...

Reviews: